3nh YG60L In-Line Non-Contact Gloss Meter
The 3nh YG60L is an industrial in-line gloss meter for non-contact surface measurements on liquids, powders, pastes and delicate samples.The compact sensor head fits automated lines for gloss checks and quality control in coatings, inks, printing, plastics, electronics, furniture, ceramics, electroplating, hardware, marble and cosmetics.The standard model provides USB and Bluetooth 5.0. 3nh lists this model for planned discontinuation. Confirm availability and service for your application.
3nh YG60L In-Line Non-Contact Gloss Meter
The 3nh YG60L is an industrial in-line gloss meter for non-contact surface measurements on liquids, powders, pastes and delicate samples.
The compact sensor head fits automated lines for gloss checks and quality control in coatings, inks, printing, plastics, electronics, furniture, ceramics, electroplating, hardware, marble and cosmetics.
The standard model provides USB and Bluetooth 5.0. 3nh lists this model for planned discontinuation. Confirm availability and service for your application.
1. Product Features
Non-contact measurement
- A working distance of 10.0 mm ± 0.1 mm helps protect the sample from contact damage and reduces probe contamination.
Sample types
- Measure liquids, pastes, powders and delicate samples. For soft, curved or uneven surfaces, confirm the measurement location and parallelism.
- Applications include paints, inks, coatings, printed paper, plastics, electronics, furniture, ceramics, plating, hardware and marble.
Reduced contact contamination
- Keeping the probe clear of the surface reduces carryover from direct probe contact when testing multiple samples.
- Evaluate for cleanliness-sensitive processes in food, pharmaceuticals and cosmetics.
2. Communication and Integration
Communication interfaces
- USB and Bluetooth 5.0.
- The manufacturer provides interface examples to support software development and integration.
Host connection
- Connect to a PC using USB or Bluetooth. Confirm the communication setup and software before attempting multi-instrument synchronization.
- Confirm GQC6 functions and compatibility for the supplied configuration.
PC software
- GQC6 allows PC-based measurements, data management and reporting.
- Use the system to monitor surface gloss in line.
Measurement output
- Readings can feed a production control system or support printed inspection reports with an optional mini printer.
3. Measurement Performance
Measurement and repeatability
- The documentation lists ISO 2813, ASTM D523 and GB/T 9754.
- The measurement range is 0–1,000 GU with 0.1 GU resolution.
- Repeatability is ±0.5 GU from 0 to 100 GU and ±0.5% GU from 100 to 1,000 GU.
- Meets JJG 696 requirements for working gloss meters.
Fast measurement
- The shortest listed measurement time is 0.2 seconds.
- Choose basic, continuous, statistical or quality-control mode.
Data storage
- Store up to 35,000 readings for production traceability.
4. Installation and Operating Conditions
Compact housing
- The unit measures 140 × 83 × 38 mm and weighs approximately 500 g for installation in confined production-line spaces.
Temperature and humidity
- Operating temperature is 0–40°C.
- Storage temperature is −20–50°C.
- Humidity is below 85% RH, non-condensing.
- Verify the mounting position, working distance and operating environment.
Power supply
- Use a USB power adapter.
Applications
The compact sensor head fits automated lines for gloss checks and quality control in coatings, inks, printing, plastics, electronics, furniture, ceramics, electroplating, hardware, marble and cosmetics.
| Model | 3nh YG60L In-Line Non-Contact Gloss Meter |
|---|---|
| Measurement geometry | 60°. Listed standards include ISO 2813, ASTM D523 and GB/T 9754. |
| Measurement spot | 9 × 15 mm |
| Measurement range | 0–1,000 GU |
| Resolution | 0.1 GU |
| Working distance | 10.0 mm ± 0.1 mm. The sample surface must be parallel to the aperture plane within 0.2°. |
| Applications and integration | Non-contact in-line measurements for liquids, pastes, powders and delicate samples. Interface examples are available. Confirm pricing and scope for custom software. |
| Measurement modes | Basic, statistical, continuous and quality control |
| Measurement time | 0.2 seconds or 1 second |
| Repeatability | 0–100 GU: ±0.5 GU, 100–1,000 GU: ±0.5% GU. Tested at 5-second intervals using a 10 mm fixture with the specified distance and parallelism. |
| Accuracy | Meets JJG 696 requirements for working gloss meters |
| Auto power-off | 30, 60, 90 or 120 seconds, or disabled |
| Calibration | Automatic calibration tile check, with manual calibration available |
| Interface languages | English, Traditional Chinese and Simplified Chinese |
| Data storage | 35,000 readings: 15,000 shared by basic and continuous modes, 10,000 in quality-control mode and 10,000 in statistical mode |
| Display | 2.3-inch monochrome display |
| Dimensions | 140 × 83 × 38 mm |
| Weight | Approximately 500 g |
| Power supply | Use a USB power adapter. |
| Communication interfaces | USB and Bluetooth 5.0 |
| PC software | GQC6 quality management and inspection reports |
| Operating temperature | 0–40°C (32–104°F) |
| Storage temperature | −20–50°C (−4–122°F) |
| Humidity | Below 85% RH, non-condensing |
| Standard accessories | Power adapter, quality management software, calibration tile and calibration bracket |
| Optional accessories | Mini printer |
| Note | Specifications are for reference. Confirm the supplied configuration. |