Multifunctional Colorimeter NR60CP
NR60CP Multifunctional Colorimeter | Dual Apertures for Routine Color Difference Checks
NR60CP multifunctional colorimeter Designed for routine QC comparison of standard and sample colors, NR60CP supports CIE Lab review and ΔE evaluation for incoming inspection, in-process checks, and pre-shipment inspection. Its selectable Φ8 mm and Φ6 mm apertures provide options for different sample areas, surface conditions, and measurement locations.
NR60CP combines illuminated positioning and crosshair alignment with a rechargeable lithium battery, built-in white-reference parameters, and a physical white tile. It suits on-site checks, portable measurements, and routine color QC. Confirm suitability for the sample material, surface, measurement area, color uniformity, and QC workflow before selection.
NR60CP Colorimeter Features
For applications that need two aperture options, quick color comparison, on-site positioning, and routine QC decisions.
Selectable Φ8 mm and Φ6 mm Apertures
Choose between Φ8 mm and Φ6 mm apertures according to sample size and measurement location. The larger aperture can suit flatter or larger samples; the smaller aperture may be evaluated for small areas or recessed locations.
Measurement Stability and Repeatability
Manufacturer information lists chromaticity repeatability of ΔE*ab < 0.05 as a reference for routine QC and batch comparison. Actual results depend on sample conditions, calibration, and operating procedures.
Multiple Color Spaces and Indices
Multiple color spaces and indices support color-difference evaluation, batch tracking, and sample comparison for different QC needs. Confirm available functions against the product specifications and software.
Illuminated Positioning and Crosshair Alignment
Illuminated positioning and crosshair alignment help operators align the measurement point for fixed-point checks, repeat measurements, and rapid on-site evaluation.
High-Capacity Rechargeable Lithium Battery
The rechargeable lithium battery supports line inspections, warehouse receiving checks, supplier incoming inspection, and portable measurement needs.
Built-In White-Reference Parameters and Physical Tile
Built-in white-reference parameters and a physical white tile support routine calibration and field use. Establish calibration intervals and measurement procedures in accordance with your internal SOP.
Updated Integrating-Sphere Design
The updated integrating-sphere design can be evaluated for measurement stability in applications that need quick color-difference data and routine QC records.
For Multiple QC Scenarios
Use cases include incoming inspection, in-process checks, batch comparison, pre-shipment inspection, and rapid on-site receiving. For samples with surface variation, consider averaging measurements or managing fixed measurement points.
Where to Evaluate the NR60CP
Flat Samples
The larger aperture can be used for quick comparison on samples with sufficient area and a relatively flat surface.
Recessed or Small-Area Samples
Evaluate the smaller aperture for the sample conditions to reduce interference from an oversized measurement area.
Routine Quality Control
Suitable for standard-to-sample comparison, incoming inspection, in-process checks, and pre-shipment review.
Portable Measurement
The rechargeable battery and handheld operation support use on production lines, in warehouses, and during on-site receiving.
Selection and Use Notes
NR60CP is intended for dual-aperture color comparison and routine QC across multiple scenarios. For glossy, textured, unevenly colored, transparent, translucent, or curved samples, first confirm the aperture, sampling location, sample fixture, averaging method, and internal acceptance criteria. If you need full spectral data, multi-illuminant analysis, SCI/SCE switching, or supply-chain color traceability, consider a handheld spectrophotometer.
Contact Fulcrum Technology about NR60CP selectionNR60CP Multifunctional Colorimeter Specification
The following specifications are provided as a reference for product selection, procurement, and routine quality-control planning. NR60CP uses D/8 measurement geometry and supports Φ6 mm and Φ8 mm apertures for rapid color-difference comparison, incoming inspection, in-process checks, and multiple QC applications. Confirm suitability based on sample material, surface condition, measurement area, color uniformity, and your QC workflow.
| Specification | Details |
|---|---|
| Product model | NR60CP colorimeter |
| Measurement geometry | D/8 (diffuse illumination, 8° directional reception, including specular component SCI); conforms to CIE No. 15 and GB/T 3978. |
| Detector | Silicon photodiode array |
| Spectral method | Not applicable |
| Integrating sphere size | Φ40 mm |
| Illumination source | Full-spectrum LED source |
| Wavelength range | Not applicable |
| Illuminants | D65, A, C, D50, F2, F6, F7, F8, F10, F11, F12 |
| Wavelength interval | Not applicable |
| Reflectance range | Not applicable |
| Measurement apertures | Φ6 mm and Φ8 mm |
| Measurement mode | SCI |
| Color spaces | CIE LAB, XYZ, LCh, CIE RGB, CIE LUV |
| Color-difference formulas | ΔE*ab, ΔE(h), ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00 |
| Other color indices | WI (ASTM E313, ISO R457, Hunter), YI (ASTM E313), staining fastness, color-change fastness, JPC79, BFD (1.5:1), FMCII |
| Observer angle | 10° |
| Displayed parameters | Sample color values, color difference, pass/fail result, color tendency |
| Measurement time | Approx. 1.5 seconds |
| Repeatability | Within ΔE*ab 0.03 (after warm-up and calibration; average of 30 white-tile measurements at 5-second intervals) |
| Inter-instrument difference | Within ΔE*ab 0.4 (average measured across 12 BCRA Series II color tiles) |
| Measurement method | Single measurement |
| Positioning method | Alignment positioning |
| Dimensions | 205 × 67 × 80 mm |
| Weight | Approx. 500 g |
| Battery | Rechargeable lithium battery |
| Illuminant life | Approx. 5 years; more than 1.6 million measurements |
| Display | 2.8-inch TFT full-color display |
| Connectivity | USB |
| Data storage | 100 standards and 20,000 samples |
| Software support | CQCS3 quality management software |
| Languages | Traditional Chinese, Simplified Chinese, English |
| Operating conditions | 0–40°C; 0–85% relative humidity (non-condensing) |
| Storage conditions | -20–50°C (non-condensing) |
| Standard accessories | Power adapter, manual, wrist strap, white tile, cable, quality management software (download), Φ8 mm platform aperture, Φ6 mm tapered aperture |
| Optional accessories | Mini printer, powder test box |
| Note | Specifications may change; confirm the latest information with Fulcrum Technology or the manufacturer. |
Selection note: NR60CP is suited to dual-aperture color comparison, flat or recessed samples, small-area measurements, and routine QC. For glossy, textured, uneven, transparent, translucent, or curved samples, confirm aperture, sampling position, fixture, averaging method, and acceptance criteria. For full spectral data, multi-illuminant analysis, SCI/SCE switching, or supply-chain color traceability, consider a spectrophotometer.