Spectrophotometer TS7020
TS7020 Spectrocolorimeter | 8 mm Aperture, SCI Measurement and QC Software
The TS7020 Spectrocolorimeter is designed for QC, R&D, and production teams building routine color inspection and QC data management workflows. Applications include Lab color data and ΔE color difference evaluation, SCI measurement, incoming inspection, in-process checks, batch comparison, and test report preparation.
TS7020 features a handheld design, uniform full-spectrum LED source, dual 24-array sensor, and an 8 mm measuring aperture. It can work with SQCX quality management software to organize data and compare color differences. It is suited to plastics, coatings, inks, textiles, printing, ceramics, and general manufacturing. Confirm sample dimensions, surface condition, measurement area, gloss variation, data management needs, and QC procedures before selecting a configuration.
TS7020 Spectrocolorimeter Features
Designed for handheld measurement, SCI color evaluation, routine QC records, and SQCX quality management software workflows.
Ergonomic Handheld Design
The handheld form is designed for comfortable operation during repeated inspections, on-site checks, incoming inspection, and routine quality control.
Uniform Full-Spectrum LED Source
The uniform full-spectrum LED source provides visible-range spectral distribution for color difference comparison, color data interpretation, and QC inspection.
Dual 24-Array Sensor
The silicon photodiode dual 24-array sensor provides a basis for color data, reflectance information, and batch color comparisons in routine QC workflows.
8 mm Measuring Aperture
The 8 mm aperture is suitable for samples with a general measurement area, flat materials, and routine inspections. For small samples, restricted measurement points, or surfaces that are difficult to contact evenly, provide sample details to confirm the appropriate model.
ETC Real-Time Calibration
TS7020 uses ETC (Every Test Calibration) technology and a standard white plate to help maintain consistent routine measurement conditions. Follow the manufacturer's procedure for calibration.
SQCX Quality Management Software
Use SQCX software to organize color data, compare color differences, and export test reports. It is suited to workflows that require QC records, supplier batch comparisons, and internal color standard management. Confirm available features and export formats for the supplied version.
How to Choose Between TS7020 and TS7010
Both are entry-level handheld spectrocolorimeters for routine color evaluation and on-site QC. Compare data management, report export, QC records, and implementation goals.
TS7010 | Basic Routine Color Inspection
For a straightforward color inspection workflow—such as incoming inspection, in-process checks, master-to-sample comparison, and pass/fail decisions—consider the TS7010 Spectrocolorimeter.
TS7020 | Routine Inspection and QC Data Management
If you also need SQCX software for data organization, batch tracking, test report export, or supplier QC records, evaluate the TS7020 Spectrocolorimeter.
| Comparison | TS7010 | TS7020 |
|---|---|---|
| Positioning | Handheld routine color inspection and basic QC | Handheld routine color inspection with QC software |
| Typical applications | Incoming inspection, in-process checks, master-to-sample comparison | Incoming inspection, in-process checks, batch records, report preparation, and supplier QC |
| Light source and sensor | Uniform full-spectrum LED source and dual 24-array sensor | Uniform full-spectrum LED source and dual 24-array sensor |
| Aperture | Confirm the specific product page and supplied version | 8 mm aperture for general-area samples and flat materials |
| Data management | Focused on rapid on-site decisions and basic QC workflows | Works with SQCX software for data organization, color comparisons, and report export |
| Selection guidance | Consider for quick implementation, routine decisions, and on-site inspection | Consider when batch tracking, report export, supplier QC records, or data retention are needed |
Selection note: Confirm actual differences against the product pages, supplied version, and QC workflow. If you have internal color tolerances, customer acceptance criteria, report formats, or calibration document requirements, provide the sample conditions before selecting a model.
TS7020 Frequently Asked Questions
Common questions about routine color inspection, SQCX software, batch data management, and implementation.
Which industries can use the TS7020?
TS7020 can be evaluated for routine color inspection in plastics, coatings, inks, textiles, printing, ceramics, and general manufacturing. Typical uses include incoming inspection, in-process checks, R&D sample comparisons, and batch color management. Confirm suitability for the sample material, surface condition, and QC workflow.
What is the difference between TS7020 and TS7010?
TS7010 is suited to basic routine color checks and on-site inspections. TS7020 is intended for workflows using SQCX software for data organization, color comparison, batch records, and test report export. Consider TS7020 if you need to retain inspection records or organize supplier acceptance information.
Can the TS7020 evaluate Lab and ΔE color differences?
TS7020 supports Lab color data and ΔE evaluation for master-to-sample comparison. Set acceptance criteria according to product characteristics, customer requirements, and internal QC standards; avoid applying a single tolerance to every material.
When is SQCX quality management software useful?
SQCX is suited to workflows that organize color data, compare color differences, retain batch records, or export test reports. Confirm supported features, export formats, and data management functions for the supplied version and your requirements.
Is the TS7020 suitable for small or curved samples?
The 8 mm aperture is a starting point for general-area samples and flat materials. For small samples, curved or uneven surfaces, texture, or unstable contact, provide sample photos, dimensions, and measurement locations to determine whether another aperture or positioning method is needed.
What information should we provide before implementation?
Provide sample material and dimensions, measurement area, surface gloss, texture or curvature, color difference formula, acceptance criteria, inspection frequency, report export and data retention needs, and supplier batch management requirements. This helps confirm whether TS7020 fits your QC workflow.
Before Implementation
For samples involving different batches or suppliers, curved or textured surfaces, gloss variation, or small measurement areas, provide the sample conditions, inspection objective, and internal criteria before confirming the aperture, SCI measurement conditions, SQCX software application, and QC data workflow.
Contact Fulcrum Technology for selection adviceTS7020 Spectrocolorimeter Specifications
Use these specifications as a reference for evaluating the TS7020 for selection, purchasing, and QC implementation. The TS7020 uses D/8 geometry with a Φ8 mm platform aperture, SCI measurement, Lab color data, ΔE evaluation, SQCX quality management software, and routine color QC functions. It is suited to incoming inspection, in-process checks, R&D comparisons, and batch color management. Confirm the configuration against sample size, surface condition, measurement area, gloss variation, data management needs, and QC procedures.
| Model | TS7020 Advanced Spectrocolorimeter |
|---|---|
| Measurement geometry | D/8 (diffuse illumination, 8° viewing); SCI; conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164, and DIN 5033 Teil 7 |
| Detector | Silicon photodiode array (dual 24-array) |
| Spectral system | Planar grating spectroscopic system |
| Integrating sphere diameter | Φ40 mm |
| Illumination source | Combined full-spectrum LED light source |
| Wavelength range | 400–700 nm |
| Illuminants | D65, A, F2 (CWF) |
| Resolution | 0.1 |
| Wavelength interval | Not specified |
| Reflectance measurement range | Measures reflectance at three user-specified wavelengths (defaults: 440 nm, 550 nm, and 600 nm) |
| Measurement aperture | Φ8 mm |
| Measurement mode | SCI |
| Color spaces | CIE LAB, XYZ, Yxy, LCh |
| Color difference formulas | ΔE*ab, ΔE*00 |
| Other colorimetric indices | Not specified |
| Observer angle | 10° |
| Displayed parameters | Reflectance at user-specified wavelengths, sample color values, color difference values/graph, pass/fail results, color simulation, and color bias |
| Measurement time | Approx. 1.5 seconds |
| Repeatability | Color value: MAV/SCI, ΔE*ab within 0.08 (average of 30 white-plate measurements at 5-second intervals after warm-up and calibration) |
| Inter-instrument difference | MAV/SCI, ΔE*ab within 0.4 (average of measurements on 12 BCRA Series II color tiles) |
| Measurement method | Single measurement or average measurement (2–99 readings) |
| Positioning | Stabilizing plate positioning |
| Dimensions | Length × width × height: 81 × 71 × 214 mm |
| Weight | 460 g |
| Battery | Rechargeable lithium battery |
| Light-source life | Approx. 5 years or more than 1.5 million measurements |
| Display | 3.5-inch TFT color capacitive touchscreen |
| Connectivity | Type-C USB (charging only); Bluetooth 5.0 |
| Data storage | 500 standards and 10,000 samples |
| Software support | Windows |
| Languages | Traditional Chinese, Simplified Chinese, and English |
| Operating conditions | 0–40°C, 0–85% relative humidity (non-condensing) |
| Storage conditions | −20–50°C (non-condensing) |
| Standard accessories | Power adapter, data cable, manual, black-and-white calibration box, protective cover, wrist strap, and single Φ8 mm platform aperture |
| Optional accessories | Mini printer, powder test box, and placement base |
Specification note: TS7020 is an entry-level handheld spectrocolorimeter with a single aperture, suited to Φ8 mm platform measurements, SCI mode, routine color difference evaluation, and Windows software data management. For small, curved, or textured samples, gloss variation, SCI/SCE switching, color-card retrieval, app extensions, or CCD viewing and positioning, evaluate other models based on actual sample conditions.