Product Aging and Quality-Control Testing
Observe changes in tensile strength, elongation, and product aging under constant-temperature conditions. Suitable for R&D, quality-control, and laboratory testing of industrial products.
The DG40 / DG50 aging test oven uses forced-air circulation and is suitable for research institutes, schools, factories, quality-control departments, and laboratories. It can be used to observe tensile strength, elongation, and product aging under constant-temperature conditions as part of industrial product quality-control testing.
The unit is designed for quiet, durable operation, accurate temperature control, and an attractive appearance. Select a model based on sample size, test temperature and duration, chamber volume, turntable requirements, and the quality-control process. Confirm actual specifications, stock, lead time, and repair service by model and requirement.
Observe changes in tensile strength, elongation, and product aging under constant-temperature conditions. Suitable for R&D, quality-control, and laboratory testing of industrial products.
Forced-air circulation works with the internal turntable motor and rack for aging tests that require circulating hot air and constant-temperature observation.
The imported microcomputer PID temperature controller performs automatic calculations and uses SSR control. Safety functions include self-diagnostics and protection against temperature abnormalities, overheating, sensor disconnection, and power faults.
The DG40 has a 72 L chamber and the DG50 has a 150 L chamber. Choose according to sample size, quantity, placement, and available laboratory space.
| Model | DG40 | DG50 |
|---|---|---|
| Circulation method | Forced-air circulation | |
| Operating temperature range | 40°C~300°C | |
| Temperature control accuracy | ±0.5°C | |
| Inner and outer chamber materials | Interior: SUS304 stainless steel; exterior: powder-coated galvanized steel | |
| Temperature control system | Imported microcomputer PID automatic-calculation temperature controller with SSR control | |
| Temperature setting / display | Touch controls; LED numeric display with simultaneous dual readout | |
| Temperature sensor | K-type platinum temperature sensor | |
| Viewing window | Double-layer safety-tempered glass, 5 mm thick; W180 × H320 mm | |
| Timer | Electronic digital timer; power is cut off automatically when the timer ends | |
| Insulation | Imported rock wool | |
| Safety devices | Self-diagnostics; protection for temperature abnormality, overheating, sensor disconnection, and power faults | |
| Circulation fan motor | 1/10 HP | 1/6 HP |
| Internal turntable motor and speed | 25 W,7–10 r.p.m | 45 W,7–10 r.p.m |
| Interior dimensions W × D × H | 450 × 400 × 400 mm | 600 × 500 × 500 mm |
| Exterior dimensions W × D × H | 770 × 550 × 740 mm | 920 × 650 × 970 mm |
| Chamber volume | 72 L | 150 L |
| Power supply | 110V / 220V,60Hz | 110V / 220V,60Hz |
| Current | 20A / 10A | 30A / 15A |
| Weight | Approx. 60 kg | Approx. 85 kg |
| Accessories | 2 shelves and 1 turntable rack | 2 shelves and 1 turntable rack |
Features: quiet, durable operation, accurate temperature control, and an attractive appearance. Suitable for research institutes, schools, factories, quality-control departments, and laboratories.
Specifications are compiled from the information provided. Confirm actual specifications, included accessories, controller version, and supplied configuration with the manufacturer or Fulcrum Technology.
When selecting an aging test oven, first confirm test temperature and duration, sample size and quantity, chamber volume, turntable requirements, power supply, and quality-control process. For specific materials, long operating periods, or fixed test conditions, provide the sample details and test objective for confirmation.
A: It is used to observe tensile strength, elongation, and product aging under constant-temperature conditions as part of quality-control testing for industrial products. It is suitable for research institutes, schools, factories, quality-control departments, and laboratories.
A: Compare sample size, chamber volume, and the number of samples. The DG40 has a 72 L chamber and the DG50 has a 150 L chamber; consider the DG50 for larger samples or higher quantities.
A: General-purpose ovens are commonly used for drying, preheating, or heating. An aging test oven is intended to observe product aging, tensile strength, elongation, and related quality-control changes at a constant temperature. Confirm the selection based on the test objective.
A: Confirm operating temperature, test duration, sample material and size, required chamber volume, turntable use, power supply, and the quality-control process.
A: Fulcrum Technology can help confirm stock, lead time, after-sales technical support, and repair services by model and requirement. Confirm the available service based on the model, equipment condition, and your needs.
Share your test temperature and duration, sample size, required chamber volume, power supply, and whether a turntable is needed. Fulcrum Technology can help assess a suitable model and supply details.