Aging Test Oven DG40 / DG50

Aging test ovens / aging test chambers are used in thermal aging, heat resistance, stability, and quality verification processes across the materials, components, electronics, plastics, chemical, printing, food, optoelectronics, and related industries. With forced-air circulation, the equipment is suitable for aging tests and quality-control applications that require stable hot-air circulation. Please confirm the actual model, dimensions, capacity, included accessories, and supply version against the manufacturer's information or with Fulcrum Technology.

Aging Test Oven DG40 / DG50

The DG40 / DG50 aging test oven uses forced-air circulation and is suitable for research institutes, schools, factories, quality-control departments, and laboratories. It can be used to observe tensile strength, elongation, and product aging under constant-temperature conditions as part of industrial product quality-control testing.

The unit is designed for quiet, durable operation, accurate temperature control, and an attractive appearance. Select a model based on sample size, test temperature and duration, chamber volume, turntable requirements, and the quality-control process. Confirm actual specifications, stock, lead time, and repair service by model and requirement.

Aging test oven · aging test equipment · DG40 · DG50 · quality-control testing

Product Aging and Quality-Control Testing

Observe changes in tensile strength, elongation, and product aging under constant-temperature conditions. Suitable for R&D, quality-control, and laboratory testing of industrial products.

Forced-air circulation

Forced-air circulation works with the internal turntable motor and rack for aging tests that require circulating hot air and constant-temperature observation.

Temperature Control and Safety

The imported microcomputer PID temperature controller performs automatic calculations and uses SSR control. Safety functions include self-diagnostics and protection against temperature abnormalities, overheating, sensor disconnection, and power faults.

Two Models: DG40 / DG50

The DG40 has a 72 L chamber and the DG50 has a 150 L chamber. Choose according to sample size, quantity, placement, and available laboratory space.

Specifications

ModelDG40DG50
Circulation methodForced-air circulation
Operating temperature range40°C~300°C
Temperature control accuracy±0.5°C
Inner and outer chamber materialsInterior: SUS304 stainless steel; exterior: powder-coated galvanized steel
Temperature control systemImported microcomputer PID automatic-calculation temperature controller with SSR control
Temperature setting / displayTouch controls; LED numeric display with simultaneous dual readout
Temperature sensorK-type platinum temperature sensor
Viewing windowDouble-layer safety-tempered glass, 5 mm thick; W180 × H320 mm
TimerElectronic digital timer; power is cut off automatically when the timer ends
InsulationImported rock wool
Safety devicesSelf-diagnostics; protection for temperature abnormality, overheating, sensor disconnection, and power faults
Circulation fan motor1/10 HP1/6 HP
Internal turntable motor and speed25 W,7–10 r.p.m45 W,7–10 r.p.m
Interior dimensions W × D × H450 × 400 × 400 mm600 × 500 × 500 mm
Exterior dimensions W × D × H770 × 550 × 740 mm920 × 650 × 970 mm
Chamber volume72 L150 L
Power supply110V / 220V,60Hz110V / 220V,60Hz
Current20A / 10A30A / 15A
WeightApprox. 60 kgApprox. 85 kg
Accessories2 shelves and 1 turntable rack2 shelves and 1 turntable rack

Features: quiet, durable operation, accurate temperature control, and an attractive appearance. Suitable for research institutes, schools, factories, quality-control departments, and laboratories.

Specifications are compiled from the information provided. Confirm actual specifications, included accessories, controller version, and supplied configuration with the manufacturer or Fulcrum Technology.

Selection Guide

When selecting an aging test oven, first confirm test temperature and duration, sample size and quantity, chamber volume, turntable requirements, power supply, and quality-control process. For specific materials, long operating periods, or fixed test conditions, provide the sample details and test objective for confirmation.

Frequently Asked Questions

Q: What is an aging test oven used for?

A: It is used to observe tensile strength, elongation, and product aging under constant-temperature conditions as part of quality-control testing for industrial products. It is suitable for research institutes, schools, factories, quality-control departments, and laboratories.

Q: How should I choose between the DG40 and DG50?

A: Compare sample size, chamber volume, and the number of samples. The DG40 has a 72 L chamber and the DG50 has a 150 L chamber; consider the DG50 for larger samples or higher quantities.

Q: How does an aging test oven differ from a general-purpose oven?

A: General-purpose ovens are commonly used for drying, preheating, or heating. An aging test oven is intended to observe product aging, tensile strength, elongation, and related quality-control changes at a constant temperature. Confirm the selection based on the test objective.

Q: Which operating conditions should be confirmed?

A: Confirm operating temperature, test duration, sample material and size, required chamber volume, turntable use, power supply, and the quality-control process.

Q: Can Fulcrum Technology confirm stock, lead time, and repair service?

A: Fulcrum Technology can help confirm stock, lead time, after-sales technical support, and repair services by model and requirement. Confirm the available service based on the model, equipment condition, and your needs.

Need help confirming DG40 / DG50 specifications or model selection?

Share your test temperature and duration, sample size, required chamber volume, power supply, and whether a turntable is needed. Fulcrum Technology can help assess a suitable model and supply details.

Contact Fulcrum Technology for specifications and selection advice
top