YL4560 45°/0° Non-contact Spectrocolorimeter

The YL4560 45°/0° non-contact spectrocolorimeter is part of Fulcrum Technology’s benchtop and inline color measurement range. It is suitable for evaluating non-contact color measurement of liquids, pastes and powders, as well as laboratory R&D, quality control and color management on automated production lines.Before selection, confirm sample type, measurement distance, surface condition, container or fixture design, line speed and the applicable quality workflow.

YL4560 Non-Contact Spectrocolorimeter | 45/0 Measurement with Adjustable Height

The YL4560 uses 45/0 optical geometry and measures without the probe touching the sample. It is intended for color analysis of liquids, pastes, powders, adhesive or contaminating samples, and other materials that are not suitable for direct-contact measurement.

Measurement height can be adjusted to suit sample height and container conditions, including different container sizes, liquid levels, or sample positions. Applications may include laboratory R&D, color data development, batch comparison, quality inspection, and color management on automated production lines.

45/0 non-contact measurement | Adjustable measuring height | Liquids, pastes and powders | Different container heights | R&D and quality control

Non-contact color measurement

The measuring probe does not need to touch the sample. This can help reduce the risk of probe contamination or residue from liquids, pastes, powders, and materials that tend to adhere, and can limit interference with the sample surface.

Adjustable measuring height

The measuring head position can be adjusted according to the sample container, liquid level, and sample height. This provides flexibility when measuring samples in containers of different sizes or heights.

R&D and quality-control workflows

The YL4560 may be used for formulation development, reference-sample creation, batch color-difference comparison, and quality-control records to support consistent color data management.

Common samples and industries

  • Liquids, pastes and powders
  • Cosmetics, food and agricultural products
  • Paints, coatings and inks
  • Printing, ceramics, plastics and electronics

YL4560 or YL4520: how to choose?

For 45/0 non-contact color measurement at a fixed height for general liquids, powders, or pastes, compare the YL4520 non-contact spectrocolorimeter. If container height, liquid level, or the actual measuring position varies and greater height adjustment is needed, evaluate the YL4560. Final selection should be based on the sample and measurement setup.

What to confirm before installation

Confirm sample type, container dimensions, sample or liquid-level height, surface uniformity, stable measuring distance, measuring aperture, measurement position, ambient-light control, calibration procedure, and internal acceptance criteria. For automated installations, also review line speed, mounting space, and sample positioning.

YL4560 Frequently Asked Questions

What samples can the YL4560 measure?

It can be evaluated for liquids, pastes, powders, and other materials that are inconvenient to measure by direct contact. It is especially relevant when sample or container height affects the measuring position.

What is the main feature of the YL4560?

In addition to 45/0 non-contact measurement, the measuring height can be adjusted to suit the sample and container, including different liquid levels and sample positions.

How does it differ from the YL4520?

The YL4520 can be considered for fixed-height 45/0 non-contact measurements. The YL4560 focuses on adjustable measuring height for applications with varying container heights, liquid levels, or sample positions. Compare both models against the actual workflow.

What should I consider when measuring liquids?

Keep the liquid level, container shape, bubbles, sample flow, and measurement position consistent. Maintain a stable distance and sample condition between measurements.

Can it be used for powder samples?

Powder applications can be evaluated. Pay attention to fill height, surface leveling, particle distribution, and sampling technique so that sample preparation does not create excessive variation between measurements.

Is it suitable for laboratory R&D?

It may support formulation work, reference-sample creation, batch comparison, and color data management, particularly where sample height or container conditions vary.

Can it be integrated into an automated production line?

Automated color measurement may be possible depending on the equipment configuration. Confirm sample positioning, measuring height, distance control, line speed, and available installation space before integration.

What information is useful for a selection review?

Provide the sample type, container dimensions and height, sample or liquid-level position, surface condition, measurement method, automation requirements, current quality criteria, and acceptable color difference.

Need help assessing the YL4560 for your samples?

Share the sample type, container height, liquid level, measurement method, and quality requirements. Contact Fulcrum Technology for YL4560 application and selection guidance, including a comparison with the YL4520.


YL4560 Non-Contact Spectrocolorimeter Specifications

Use the following specifications as a reference when evaluating, purchasing, or planning an installation. The YL4560 uses 45/0 optical geometry and non-contact measurement. It may be evaluated for color measurement of liquids, pastes, powders, cosmetics, food, plastics, paints and inks, printed materials, ceramics, and other samples. Confirm sample type, container height, distance stability, aperture, calibration, and quality criteria for the intended application.

ItemSpecification
ModelYL4560
Product name45/0 non-contact benchtop spectrocolorimeter
Illumination geometry45/0 (uniform 45° ring illumination, 0° viewing)
StandardsCIE No.15; GB/T 3978; GB 2893; GB/T 18833; ISO 7724-1; ASTM E1164; DIN 5033 Part 7
Product featuresBenchtop grating spectrocolorimeter with non-contact probe-to-sample measurement for liquids, pastes, powders, and other applications. May be used in laboratories, R&D, color-data communication, automated-line color quality control, cosmetics, produce, food hygiene, plastics and electronics, paints and inks, printing, and ceramics. Fluorescent samples may be assessed for suitability based on their characteristics.
Illumination sourceFull-spectrum LED and UV light sources
Spectral methodConcave grating
SensorDual-array CMOS image sensor, 256 pixels
Wavelength range400–700 nm; 10 nm output interval
Reflectance range0–200%
Measuring apertureΦ20 mm (custom apertures <20 mm may be available; confirm requirements)
Non-contact distance7.5 mm (±0.2 mm)
Sample height0–160 mm with the supplied support base
Distance adjustmentManual or automatic adjustment; measurement height can be stored
Measurement modesSample mode, QC mode, and continuous statistics mode
PositioningWebcam positioning
Color spacesCIE LAB, XYZ, Yxy, LCh, CIE LUV, HunterLAB
Color-difference formulasΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, ΔE (Hunter)
Other color indicesWI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM E313), metamerism index MI, staining fastness, color-change fastness, tinting strength, and hiding power
Observer angles2° / 10°
IlluminantsD65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30)
DisplaySpectra and data, sample color values, color difference values/graphs, pass/fail results, and color direction
Measurement timeApprox. 1.0 s in fast mode; adjustable range approx. 0.2–1.5 s
Data storageApprox. 40,000 records in sample and QC modes; approx. 10,000 records in continuous statistics mode
RepeatabilitySpectral reflectance: standard deviation within 0.08%; color value: ΔE*ab within 0.03 (after warm-up, average of 30 white-tile measurements at 5-second intervals)
Inter-instrument differenceΔE*ab within 0.2 (average across 12 BCRA Series II color tiles)
Measurement methodSingle measurement or averaging (2–99 measurements)
Dimensions330 × 250 × 370 mm
WeightApprox. 10 kg
PowerDC 24 V, 3 A power adapter
Light-source life5 years; more than 3 million measurements
Display screen7-inch TFT true-color capacitive touchscreen
InterfacesUSB / RS-232, Bluetooth 5.0
Operating languagesSimplified Chinese, Traditional Chinese, English
Operating environment0–40°C, 0–85% RH (non-condensing), altitude below 2,000 m
Storage environment−20–50°C, 0–85% RH (non-condensing)
Standard accessoriesPower cord, manual, data cable, standard calibration tile, and black calibration box
Calibration / verificationServices or documents may be reviewed according to calibration, metrology, or verification needs. Confirm document content, scope, and procedure with Fulcrum Technology.
NoteSpecifications may change. Confirm current details with Fulcrum Technology or the latest manufacturer documentation.

Selection guidance

The YL4560 is a non-contact benchtop spectrocolorimeter for liquids, pastes, powders, and samples that are unsuitable for contact measurement. Its adjustable measuring height may be useful when sample or container height varies. Before implementation, confirm the container, sample height, distance stability, measuring aperture, camera positioning, calibration procedure, and acceptance criteria. For automated lines, databases, or real-time decision workflows, have an engineer assess the equipment and data format for the actual site.

top