Precision constant-temperature incubator for laboratory useA precision constant-temperature incubator helps maintain a controlled thermal environment for laboratory incubation and research workflows. Potential applications include microbiology, biochemical experiments, cell and tissue culture, genetics research, and other procedures that require a defined incubation temperature. Select a configuration according to the sample, protocol, required temperature, workload, and available installation space.Models in the DB seriesThe listed models are DB30, DB45, DB60, and DB120. The reference operating range provided for the series is ambient temperature +5°C to 70°C. Usable volume, internal dimensions, temperature uniformity, stability, and included accessories can vary by model or configuration. Confirm the technical data for the selected unit in writing before purchase.Listed modelItems to confirm before orderingDB30Usable volume, chamber dimensions, shelf arrangement, and electrical requirementsDB45Usable volume, chamber dimensions, shelf arrangement, and electrical requirementsDB60Usable volume, chamber dimensions, shelf arrangement, and electrical requirementsDB120Usable volume, chamber dimensions, shelf arrangement, and electrical requirementsTypical application considerationsIncubation and microbiological culture when the validated protocol is compatible with the unit.Biochemical testing that requires a stable, controlled temperature.Cell or tissue culture and genetics research when the required conditions match the equipment specification.Laboratory holding of samples only within the approved temperature and handling limits for the method.Selection checklistDefine the set point, incubation duration, acceptable temperature variation, and recovery expectations after door opening.Estimate sample load, container dimensions, shelf count, and clearance needed for airflow.Measure the installation footprint, door swing, room conditions, and available electrical supply.Discuss cleaning practices, sample type, door-opening frequency, and any monitoring or record-keeping needs.Request confirmation of the exact model, usable volume, chamber dimensions, performance data, and supplied accessories.Custom dimensions or configurations may be requested for review. Feasibility, lead time, and final specifications require supplier confirmation for each order.Frequently asked questionsWhat temperature range is listed?The reference range provided is ambient temperature +5°C to 70°C. Confirm the actual operating range for the selected model and the ambient conditions at the installation site.What capacity do DB30, DB45, DB60, and DB120 provide?The model names alone do not establish usable capacity. Please consult the current specification sheet or obtain written confirmation from the supplier rather than inferring volume from the model code.Can a custom size be requested?You may submit a request for review. Custom dimensions, build feasibility, delivery time, and final configuration are subject to technical review and quotation.See the low-temperature B.O.D. incubator for a different incubation application and temperature range.For model and configuration guidance, contact Fulcrum Technology with your application, temperature requirement, sample load, installation space, and electrical requirements.

Precision Constant-Temperature Incubator

The precision constant-temperature incubator is suitable for microbial cultivation, biochemical experiments, cell and tissue culture, genetic studies, and general laboratory incubation. Before selecting a model, confirm the required temperature range, chamber capacity, sample quantity, container dimensions, shelf requirements, and incubation time; then compare DB30, DB45, DB60, and DB120.

Fulcrum Technology can help assess constant-temperature incubators for laboratories, R&D units, schools, quality-control work, and testing workflows based on product information and your application. Confirm actual specifications, stock, lead time, custom dimensions, and repair services for the selected model and requirements.

Precision Incubator Constant-Temperature Incubator Microbial Cultivation Biochemical Experiments Cell and Tissue Culture

Constant-Temperature Incubation

Suitable for microbial, biochemical, cell and tissue, genetic, and general cultivation workflows requiring stable temperature conditions for laboratory incubation and observation.

Temperature Control Above Ambient

The temperature range is ambient +5°C to 70°C, suitable for constant-temperature incubation above ambient, biochemical experiments, and laboratory sample observation.

Viewing Door and Temperature Control

An inner viewing door helps reduce temperature loss while observing samples. The unit features a full-touch panel, a microcomputer PID temperature controller with dual-line display, and SSR control.

Model Options by Capacity

The DB series includes DB30, DB45, DB60, and DB120 models with capacities of 30 L, 72 L, 150 L, and 420 L, respectively. Select a model based on sample quantity, container dimensions, and available laboratory space.

Specifications

ModelDB30DB45DB60DB120
Temperature RangeAmbient +5°C to 70°C
Temperature ControllerFull-touch panel, microcomputer PID temperature controller with dual-line display, SSR control
Temperature Accuracy±0.1°C
Viewing DoorInner viewing door helps reduce temperature loss
Temperature SensorPT100Ω platinum temperature probe
MaterialsStainless-steel interior and powder-coated galvanized-steel exterior
Air CirculationGentle air circulation inside the chamber
HeaterImported heater
Safety ProtectionPower protection switch and independent over-temperature protector
Interior Dimensions W × D × H340 × 300 × 300 mm450 × 400 × 400 mm600 × 500 × 500 mm700 × 500 × 1200 mm
Exterior Dimensions W × D × H450 × 450 × 700 mm560 × 550 × 740 mm730 × 650 × 970 mm810 × 720 × 1750 mm
Capacity30L72L150L420L
Heater180W250W400W1200W
Power Supply110V110V110V110V / 220V
Accessories2 movable shelves2 movable shelves2 movable shelves5 movable shelves

Custom dimensions, from small to large, may be available. For special capacity, chamber dimensions, or incubation requirements, provide the operating temperature, sample dimensions, capacity, and use case for confirmation.

Specifications are compiled from the supplied information. Confirm actual specifications, custom dimensions, included accessories, controller version, and supplied configuration with the manufacturer or Fulcrum Technology.

Model Selection

When selecting a precision constant-temperature incubator, confirm the incubation temperature, sample quantity, container dimensions, chamber capacity, shelf requirements, incubation time, and operating environment. For custom dimensions, provide the target chamber dimensions, sample conditions, and workflow for confirmation.

Frequently Asked Questions

Q: What are the main uses of a precision constant-temperature incubator?

A:Precision constant-temperature incubators are used for microbial cultivation, biochemical experiments, cell and tissue culture, genetic studies, and general laboratory incubation.

Q: How should I choose between DB30, DB45, DB60, and DB120?

A:Choose based on capacity, interior dimensions, sample quantity, and shelf requirements. DB30 has a capacity of 30 L, DB45 72 L, DB60 150 L, and DB120 420 L.

Q: What is the difference between a precision and a low-temperature incubator?

A:The precision incubator operates at ambient +5°C to 70°C for incubation above ambient. Low-temperature / B.O.D. incubators are intended for low-temperature incubation and BOD testing.

Q: Can custom dimensions be ordered?

A:Custom dimensions, from small to large, may be available for this series. Confirm manufacturable dimensions, specifications, and lead time based on sample conditions, chamber dimensions, and the intended use.

Q: Can Fulcrum Technology confirm stock, lead time, and repair services?

A:Fulcrum Technology can help confirm stock, lead time, after-sales technical support, and repair services based on the model and your needs. Actual service availability depends on model, operating condition, and requirements.

Need help confirming precision incubator specifications and model selection?

Provide the operating temperature, sample dimensions, capacity, incubation conditions, and whether custom dimensions are required. Fulcrum Technology can help assess a suitable model and availability.