Does every SE Series system include a high-shear homogenizer?
No. A high-shear homogenizing and emulsifying module is an optional configuration. Confirm whether it is included in the selected model and quotation.
The SE Series compact laboratory vacuum reactor system is a modular AMM platform for formulation research, small-batch trials and process-condition testing. Depending on the selected configuration, it can combine agitation, dispersion, emulsification, homogenization, vacuum sealing and temperature control for mixing and formulation work in a closed or vacuum environment.
Models include SE-1L, SE-2L, SE-5L and SE-10L. Published series data includes up to 10 L stirring working capacity, a vacuum condition of −0.096 MPa, a maximum operating temperature of 120°C and a maximum viscosity rating of 70,000 cP. Actual working volume and performance depend on the model, sample properties and equipment configuration.
Combine agitation, dispersion, emulsification, vacuum and temperature-control options to suit laboratory objectives and process steps.
The published vacuum condition is −0.096 MPa. Deaeration results depend on sample viscosity, foaming behavior and operating conditions.
A homogenizing module can support emulsification, dispersion and formulation trials. Confirm motor power and speed for the selected module.
Anchor-scraper agitation is listed; ribbon impellers and other arrangements should be confirmed for the selected model and material.
Circulating heating can be configured for the process. Higher-temperature requirements need separate confirmation.
Borosilicate glass vessels are listed. SUS316L stainless-steel vessels may be evaluated as an option; confirm wetted materials for the order.
Stirring and emulsifying working capacities are not necessarily the same. Select a model according to the required process volume and confirm the usable range for the sample and configuration.
| Model | Stirring working capacity | Emulsifying working capacity |
|---|---|---|
| SE-1L | 0.3–1 L | 0.6–1 L |
| SE-2L | 0.5–2 L | 1–2 L |
| SE-5L | 1–5 L | 2–5 L |
| SE-10L | 3–10 L | 5–10 L |
These ranges are published by AMM. Applicable capacity may vary with viscosity, mixing method, homogenizing head, liquid level and process conditions.
| Specification | Published series information |
|---|---|
| Models | SE-1L, SE-2L, SE-5L, SE-10L |
| Power supply | 220 V / 50–60 Hz; confirm model and order configuration |
| Maximum operating temperature | 120°C; higher-temperature configuration may be available |
| Heating | Water- or oil-bath circulation |
| Vacuum | −0.096 MPa; positive-pressure function is optional |
| Maximum viscosity rating | 70,000 cP |
| Agitator motor power | 120 W / 180 W, depending on model |
| Agitator speed | 13–200 rpm; high-speed configuration is optional |
| Agitator | Anchor scraper; ribbon impeller optional |
| Wall-scraper material | Silicone; rigid PTFE scraper optional |
| Homogenizer motor power | 500 W / 1,050 W, depending on selected module |
| Homogenizer speed | 10,000–28,000 rpm or 5,000–25,000 rpm, depending on module |
| Speed display | LCD display |
| Lifting | Electric lift listed; semi-automatic pneumatic lift optional |
| Lifting stroke | 210 mm / 280 mm, depending on model |
| Vessel | Borosilicate glass; SUS316L stainless-steel vessel optional |
| Wetted materials | SUS316L, PTFE and borosilicate glass, subject to configuration |
This table summarizes published AMM SE Series information. Some values vary by model or optional module. Confirm electrical supply, lifting arrangement, accessories and final delivery configuration against the approved quotation and technical documents.
Evaluate mixing, emulsification, homogenization and vacuum deaeration for lotions, creams, gels and related formulations.
Assess mixing and dispersion for resins, coatings, adhesives and polymer materials. Confirm equipment loading for high-viscosity samples.
Configure mixing, emulsification, homogenization and temperature control as required. Confirm contact materials, cleaning, sterilization and compliance needs.
Use pilot trials to evaluate wetting, mixing, dispersion and vacuum deaeration. Confirm the module and process if a target particle size or higher shear is required.
Define the batch quantity and distinguish stirring from emulsifying working capacity.
Describe initial viscosity, changes during processing and expected mixing resistance.
Confirm whether vacuum mixing, deaeration, sealed operation or atmosphere control is needed.
Specify the required module, dispersion result and processing time.
State target temperature, heating method, hold time and circulation needs.
Confirm wetted materials, chemical compatibility, changeover and cleaning procedures.
Modular design does not mean every system includes high-shear homogenization, positive-pressure operation, high-temperature equipment or every agitator option. Confirm actual functions for the selected model and configuration.
The 70,000 cP viscosity rating, −0.096 MPa vacuum condition, 120°C temperature rating and working-capacity ranges do not imply that all limits can be used simultaneously. Evaluate sample properties, batch volume, speed, temperature and operating time together.
| Equipment | Primary purpose | Typical selection focus |
|---|---|---|
| SE Series vacuum reactor | Integrates agitation, vacuum and temperature control | Sealed mixing, vacuum deaeration and optional emulsification/homogenization |
| Laboratory stirrer | Liquid mixing and agitation | General mixing, dissolution, suspension and pre-dispersion |
| High-shear homogenizer | High-shear dispersion and emulsification | Emulsification, homogenization, dispersion and deagglomeration |
For general liquid mixing, see the Laboratory Stirrer. For high-shear emulsification and dispersion, see the High-Shear Homogenizer. Learn more about the difference between a homogenizer and a mixer.
The series includes SE-1L, SE-2L, SE-5L and SE-10L. Stirring and emulsifying working capacities differ; choose according to the required process volume.
The series is designed for vacuum-process applications and lists a vacuum condition of −0.096 MPa. Results depend on sample viscosity, bubble behavior and operating conditions.
The published maximum is 120°C, with higher-temperature options available for evaluation. Confirm the supplied temperature-control configuration.
The published maximum viscosity rating is 70,000 cP. Actual performance depends on batch volume, agitator, motor, sample rheology and operating speed.
Share your batch volume, viscosity, ingredients, process steps, vacuum and temperature requirements, wetted materials and cleaning needs. The technical team can review the model, drawing and final configuration.
No. A high-shear homogenizing and emulsifying module is an optional configuration. Confirm whether it is included in the selected model and quotation.
Positive-pressure operation is listed as an option and is not standard on every configuration. Confirm the pressure rating, sealing design and required safety provisions before use.
The published standard SE Series specifications do not identify an ultrasonic-dispersion module. If ultrasound is required, confirm integration feasibility or evaluate a separate ultrasonic homogenizer.
Share the sample type and quantity, viscosity, powder content, process objective, stirring or emulsification needs, vacuum and temperature conditions, wetted materials and cleaning requirements.
Published maximum viscosity, vacuum, temperature and working-volume values do not mean that all limits can be used simultaneously. Confirm the operating envelope for the selected model, sample and configuration.
The following images illustrate the SE Series laboratory vacuum reactor vessel, support frame, stirring and homogenizing modules, ports and selected accessories. They are reference views for understanding the equipment layout; the supplied arrangement depends on the model and options listed in the quotation.
Review the overall vessel, stand, stirring assembly and homogenization module arrangement. Confirm the actual module and lifting configuration for the selected model and delivery scope.
This view shows the reactor vessel, agitation system, homogenizing module and lid connections. Vacuum mixing, wall-scraping and emulsification functions must be confirmed against the chosen process configuration.
The modular system can be evaluated for vacuum, temperature control, stirring, emulsification and homogenization during formulation research and small-batch trials, subject to the supplied configuration.