KS006 Multi-Angle Spectrophotometer (6 Angles)

The KS006 multi-angle spectrophotometer is designed for gonioapparent color evaluation of metallic and pearlescent coatings, solid colors, special-effect colors, automotive topcoats, plastic parts, cosmetic packaging, and industrial coatings. Its six-angle simultaneous measurement system measures at 45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, and 45as110° to help document color changes at different viewing angles. Select the model based on coating type, effect pigments, flat or curved sample geometry, surface gloss, required measurement angles, data management, and quality-control workflow.

Product Overview

KS006 Multi-Angle Spectrophotometer | Six-Angle Measurement for Metallic, Pearlescent and Special-Effect Colors

KS006 multi-angle spectrophotometer is designed for multi-angle color evaluation of metallic, pearlescent, solid, and special-effect colors, automotive topcoats, plastic parts, cosmetic packaging, and decorative coatings. Unlike a conventional single-angle colorimeter, the KS006 uses eight light sources with one receiver to measure six angles simultaneously: 45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, and 45as110°. This helps document color shifts in gonioapparent materials at different viewing angles.

Metallic flakes, pearlescent pigments, and other effect pigments can appear different in lightness, chroma, or hue at face, side, and highlight angles because of pigment orientation, coating conditions, curved surfaces, and gloss. The KS006 can support evaluation for automotive coatings, special-effect paints, plastic components, cosmetic packaging, and supply-chain color management. Confirm suitability based on coating and pigment types, sample geometry, required measurement angles, and quality-control workflow.

Key Features

KS006 Multi-Angle Spectrophotometer Applications

Designed for multi-angle color assessment of metallic, pearlescent, solid, special-effect, and gonioapparent materials.

01

Six-Angle Simultaneous Measurement

Measures six angles simultaneously—45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, and 45as110°—to build color data across viewing angles.

02

For Metallic and Pearlescent Coatings

Suitable for metallic, pearlescent, solid, and special-effect colors on automotive topcoats, plastic parts, cosmetic packaging, industrial coatings, and decorative surfaces.

03

Document Appearance Differences by Angle

For materials with noticeable differences at face, side, and highlight angles, multi-angle data can help quality-control, R&D, and supply-chain teams build a more complete color-comparison record.

04

Evaluate Flat and Curved Parts

Assess the application according to sample shape, measurement location, and surface condition; suitable for incoming inspection, R&D comparison, and pre-shipment checks of appearance parts, coated parts, and packaging.

05

Color Analysis and Standards

Supports multiple color spaces, color-difference formulas, illuminants, and observer angles; comparison conditions can be established according to customer requirements, industry standards, or internal quality-control workflows.

06

Confirm Measurement Conditions Before Adoption

Before adopting the KS006, confirm whether samples exhibit gonioapparent, metallic-flake, or pearlescent effects, and review measurement angles, flat or curved geometry, gloss, reference-standard setup, data management, and internal acceptance criteria.

Selection Guidance

For metallic, pearlescent, special-effect, automotive coating, or cross-supplier color-management needs, the KS006 is a starting point for evaluating a six-angle solution. For simpler needs, consider whether the KS003 or a conventional D/8 or 45°/0° spectrophotometer is sufficient. For more angles or broader special-effect color analysis, consider multi-angle models such as the MS3006, MS3008, or MS3012. Confirm the final choice against sample conditions, inspection objectives, and quality-control workflows.

Contact Fulcrum Technology to Discuss KS006 Selection

Specifications

KS006 Multi-Angle Spectrophotometer Specifications

The specifications below are provided as a reference for product selection, procurement, and quality-control implementation. The KS006 uses a six-angle measurement system and measures 45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, and 45as110° simultaneously. It is suitable for multi-angle color management of metallic, pearlescent, solid, and special-effect colors, automotive topcoats, plastic parts, cosmetic packaging, and industrial coatings. Confirm suitability based on coating type, effect pigments, flat or curved sample geometry, surface gloss, required measurement angles, and quality-control workflow.

Product ModelKS006
Product NameMulti-Angle Spectrophotometer
SeriesKS006 Series Multi-Angle Spectrophotometer
Measurement Geometry6 measurement angles (8 light sources, 1 receiver)
Color Measurement Angles45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, 45as110°
StandardsMore than 10 international standards, including ASTM D2244, DIN 5033, ISO 7724, and SAE J1545
Product FeaturesSimultaneous six-angle measurement for establishing and comparing gonioapparent color data for metallic, pearlescent, solid, and special-effect colors. Confirm actual performance based on sample conditions and internal acceptance criteria.
Applicable Color TypesMetallic, pearlescent, solid, and special-effect colors
Workpiece ShapesFlat and curved workpieces
Measurement SpeedApproximately 1 second per angle
Full-Angle Measurement TimeApproximately 6 seconds for all six angles
Colorimetric Repeatability0.02 ΔE*ab
Spectral Reflectance RepeatabilityStandard deviation within 0.08%
Measurement CapabilityMeasures multi-angle appearance differences for quality control and color-data management of gonioapparent materials
Main ApplicationsAutomotive topcoats, plastic parts, cosmetic packaging, industrial coatings, and special decorative surfaces
Quality Management ApplicationsSpecial-effect color comparison, incoming inspection, process monitoring, and shipment acceptance
Application DescriptionSimultaneous multi-angle measurements can reduce positional variation caused by repeatedly changing measurement angles and help establish a more consistent color-comparison workflow. Actual benefits depend on sample shape, measurement location, and operating procedures.

Specification note: The KS006 is intended for applications requiring six-angle measurement of metallic, pearlescent, solid, and special-effect colors. For samples with pronounced gonioapparent effects, metallic-flake orientation differences, pearlescence, or curved appearance surfaces, provide sample conditions, required angles, surface gloss, reference-standard setup, and data-management workflow to confirm suitability for your quality-control requirements. Confirm final supply contents, complete specifications, software functions, and accessories with Fulcrum Technology.

top