YS4560 Plus 45/0 Spectrophotometer with CCD Positioning for Automotive Coatings
YS4560 Plus 45/0 Spectrophotometer | CCD Positioning for Color Inspection
The YS4560 Plus combines 45°/0° color measurement with CCD positioning for inspection of traffic signs, road markings, reflective films, automotive coatings, plastics, electronics, paints and inks, textiles, printing, and ceramics. It records reflectance and Lab values and evaluates color difference for incoming inspection, in-process checks, and pre-shipment acceptance.
For signs, markings, and reflective films, the instrument supports luminance-factor and chromaticity-coordinate evaluation, standard colors under GB 2893 and GB/T 18833, and manually configured polygon or rectangular tolerances. Confirm the applicable standards and tolerance method for each inspection program.
YS4560 Plus Applications and Measurement Workflow
Designed for objective color inspection of reflective and non-reflective materials across manufacturing and quality-control applications.
45°/0° Color Measurement
Uses 45°/0° measurement geometry to record reflectance and Lab values for objective surface-color comparison.
CCD Positioning
CCD positioning supports locating the intended measurement area, which is useful when inspecting signs, road markings, reflective films, and other defined regions.
Reflective-Surface Evaluation
Supports luminance-factor and chromaticity-coordinate evaluation for traffic signs, road markings, and reflective films; verify the applicable method and standard.
Multiple Material Applications
Can be applied to automotive coatings, plastics, electronics, paints and inks, textiles, printed materials, and ceramics.
Color Difference and Tolerance Checks
Evaluates color difference and supports manually configured polygon or rectangular tolerances for defined inspection requirements.
Quality Control from Incoming to Shipment
Use reflectance and Lab records for incoming inspection, in-process checks, batch comparison, and pre-shipment acceptance. Define reference standards and acceptance criteria for a repeatable workflow.
Selection Guidance
Before adoption, confirm sample material, gloss and texture, measurement area, applicable standards, tolerance method, and quality-control workflow. Verify that CCD positioning and 45°/0° geometry fit the application and sample. Contact Fulcrum Technology to discuss configuration and inspection requirements.
Contact Fulcrum Technology for YS4560 Plus selection advice429 container
YS4560 Plus Technical Specifications
Use the specifications below for product evaluation and selection. The YS4560 Plus combines 45°/0° color measurement with CCD positioning for reflective and non-reflective samples. Confirm the aperture, positioning fixture, applicable standard, and tolerance method for the intended inspection workflow before ordering.
| Model | YS4560 Plus |
|---|---|
| Illumination geometry | 45/0 (annular illumination at 45°, viewing at 0°); compliant with CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164, and DIN 5033 Part 7 |
| Features | Enhanced spectrophotometer with dual Φ8 and 4 mm apertures for accurate laboratory color analysis and communication. Supports color measurement and quality control for plastics/electronics, paints/inks, textiles/dyeing, printing, and ceramics, including fluorescent samples. Measures luminance factor and chromaticity coordinates of signs, road markings, and reflective films; includes GB 2893 and GB/T 18833 standard colors and manual polygon or rectangular tolerance settings. |
| Integrating sphere size | Φ48 mm |
| Light source | Combined LED and UV light sources |
| Spectral separation | Concave grating |
| Sensor | Dual-array 256-pixel CMOS image sensor |
| Wavelength range | 400–700 nm |
| Wavelength interval | 10 nm |
| Half bandwidth | 10 nm |
| Reflectance range | 0–200% |
| Measurement apertures | Two apertures: MAV Φ8 mm/Φ10 mm; SAV Φ4 mm/Φ5 mm |
| Color spaces | CIE LAB, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, βxy |
| Color difference formulas | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, ΔE (Hunter) |
| Other color indices | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM E313), metamerism index MI, staining fastness, color change fastness, tint strength, opacity, and polygon color tolerances |
| Observer angles | 2°/10° |
| Illuminants | D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83/U30) |
| Display | Spectral graphs/data, sample color values, color difference values/graphs, pass/fail results, and color trends |
| Measurement time | Approximately 1.5 seconds |
| Repeatability | MAV spectral reflectance: standard deviation ≤0.08% (≤0.18% over 400–700 nm); MAV color value: ΔE*ab ≤0.03 after instrument warm-up and calibration, based on 30 measurements of a white tile at 5-second intervals |
| Inter-instrument difference | MAV, ΔE*ab ≤0.15 (BCRA Series II, average of 12 color tiles) |
| Positioning method | CCD and positioning fixture |
| Measurement modes | Single measurement and average measurement (2–99 readings) |
| Dimensions | Length × width × height: 184 × 77 × 105 mm |
| Weight | Approximately 600 g |
| Battery capacity | Lithium battery; up to 5,000 measurements or 8 hours |
| Light source lifetime | 5 years or more than 3 million measurements |
| Display screen | 3.5-inch true-color TFT capacitive touchscreen |
| Interfaces | USB and dual-mode Bluetooth® 4.0 (compatible with 2.1) |
| Data storage | 1,000 standard samples and 30,000 test samples |
| Languages | Traditional Chinese, Simplified Chinese, and English |
| Operating conditions | 0–40°C; 0–85% relative humidity, non-condensing; altitude below 2,000 m |
| Storage conditions | −20–50°C; 0–85% relative humidity, non-condensing |
| Standard accessories | Power adapter, data cable, built-in lithium battery, user manual, quality-control software (download from the official website), black/white calibration box, and protective cover |
| Optional accessories | Mini printer, powder test box, and multifunctional test component |
| Note | Specifications are for reference only; the actual delivered product shall prevail. |
Selection note: Actual configuration and functions may vary by model or version. Confirm the sample, measurement area, applicable standards, and required CCD positioning with the supplier before finalizing the configuration.