AiT CMT-SR5000 12-Inch Wafer Four-Point Probe Sheet Resistance and Resistivity Measurement System
CMT-SR5000 Sheet Resistance Measurement for 12-Inch Wafers and Large-Area Films
The CMT-SR5000 supports surface-resistance measurement for wafers, films, glass, solar materials, and conductive materials. It is suitable for R&D, process monitoring, and quality-control analysis. Confirm sample dimensions, material structure, measurement locations, and analysis requirements before implementation.
Supports 300 mm wafers and large samples
Designed for measurements on 300 mm wafers. Surface-resistance testing of large samples such as 210 × 1210 mm films and glass can also be evaluated according to application needs.
Multiple measurement units
Results can be displayed in ohm, ohm/sq, ohm·cm, and S to support data review across different materials and process conditions.
Standalone operation or computer control
Choose standalone operation or computer-software control for measurement, data organization, and subsequent analysis according to the workflow.
2D and 3D analysis maps
Analysis software can generate 2D contour maps or 3D plots from measurement data to help review electrical distribution and uniformity across wafers, films, or glass samples.
High-accuracy JANDEL probe head
The JANDEL probe head is a key configuration for contact-type surface- and sheet-resistance measurements. Confirm measurement conditions against the sample surface and inspection workflow.
Selection note: For 12-inch wafer sheet-resistance measurements or distribution analysis on large films and glass, confirm sample dimensions, expected resistance range, measurement locations, 2D/3D mapping needs, data export, and quality-control workflow.
CMT-SR5000 Sheet Resistance Measurement Specifications
These specifications provide an initial reference for surface-resistance measurements on 300 mm wafers, films, glass, and solar materials. Confirm actual measurement conditions according to sample dimensions, material structure, resistance range, measurement locations, and the quality-control workflow.
| Specification item | CMT-SR5000 details |
|---|---|
| Measurement range | 1 mΩ/sq–2 MΩ/sq |
| Operating method | Place the sample on the measurement stage and press the measurement key. The system automatically adjusts the range and displays the reading, decimal point, and multiplier. |
| JANDEL four-point probe | Equipped with a JANDEL-designed quick-connect fitting/converter probe. No special tools or alignment fixture are required, and installation can be completed quickly. A JANDEL probe is included as standard. |
| Measurement data display | Measurement data is displayed directly on the equipment's main-panel display. |
| Measurement speed | Approx. 2 ± 1 seconds/point |
| Internal component accuracy | ±0.5% (high-precision resistor) |
| Maintenance and service | Microprocessor technology supports reliable operation. Electronic components are installed on replaceable printed circuit boards to facilitate maintenance and service evaluation. |
Note: The information above is provided as a reference. Actual measurement performance depends on sample surface condition, contact conditions, probe configuration, measurement environment, and data-analysis requirements.