Precision Oven DOS30 / DOS45 / DOS60
Precision Oven | DOS30, DOS45 and DOS60 Forced-Air Circulation Ovens
The DOS30, DOS45 and DOS60 precision ovens use forced-air circulation and operate from 40°C to 250°C, with chamber capacities of 30 L, 72 L and 150 L, respectively. They are suited to laboratory sample drying, material pre-treatment, quality-control inspection, research testing and small-scale process heating. Select a DOS model according to sample size, batch quantity, target temperature, power supply and available space.
Forced-Air Circulation
Forced-air circulation helps move hot air through the chamber, supporting precision-oven applications such as sample drying, constant-temperature heating, material pre-treatment and quality-control testing.
Touchscreen Control Panel
The microcomputer PID controller and LED digital display make it easy to set and monitor temperature, for laboratory and quality-control applications that require stable temperature control.
Three Capacities: DOS30, DOS45 and DOS60
The DOS30, DOS45 and DOS60 offer capacities of 30 L, 72 L and 150 L, respectively. Choose a capacity based on sample quantity, chamber space and loading requirements.
How to Choose a DOS30, DOS45 or DOS60 Precision Oven
For laboratory sample drying, R&D testing or quality-control inspection, first confirm sample dimensions, batch quantity, target temperature, drying time, available power and installation space. DOS30 suits smaller capacity needs, DOS45 is a mid-capacity option, and DOS60 is suited to larger batches or a larger chamber.
DOS30, DOS45 and DOS60 Specifications
| Model | DOS30 | DOS45 | DOS60 |
|---|---|---|---|
| Circulation method | Forced-Air Circulation | ||
| Operating temperature range | 40℃~250℃ | ||
| Temperature control accuracy | ± 0.1℃ | ||
| Inner and outer chamber materials | Stainless steel inner chamber; powder-coated galvanized steel exterior | ||
| Temperature control system | Full-touch panel, microcomputer PID temperature controller with dual digital displays, and SSR control | ||
| Temperature setting / display | Touch operation, LED digital display with simultaneous dual readouts | ||
| Temperature sensor | PT platinum sensor | ||
| Viewing window | 5 mm double-layer safety tempered glass; W180 x H320 mm | ||
| Timer | LED digital display; range 1–99 hours 59 minutes | ||
| Insulation material | Imported rock wool | ||
| Safety features | Independent over-temperature protector, self-diagnostic function, and protection for temperature abnormalities, overheating, open circuits and power | ||
| Blower motor | 1/10HP | 1/8HP | 1/6HP |
| Internal dimensions | W340 x D300 x H300mm | W450 x D400 x H400mm | W600 x D500 x H500mm |
| External dimensions | W450 x D440 x H700mm | W565 x D550 x H740mm | W735 x D650 x H970mm |
| Chamber capacity | 30L | 72L | 150L |
| Power supply | 110V 50/60Hz | 110V 50/60Hz | 220V 50/60Hz |
| Current | 8A | 12A | 12A |
| Weight | Approx. 38 kg | Approx. 48 kg | Approx. 70 kg |
| Accessories | Upper and lower adjustable shelves with support frames; 2 rod-type shelves | ||
Specifications are compiled from the current product page and available product information. Confirm specifications, included accessories and the supplied version with the manufacturer or Fulcrum Technology.
Applications and Product Features
Applications:High-tech electronics companies, research institutes, schools, factories, quality-control departments and laboratories.
Product features:The removable panel simplifies maintenance. The durable membrane touchscreen has a refined appearance and supports sample drying and pre-treatment applications that require temperature control.
Related Drying Equipment and Selection Guides
DOS Series Precision Oven FAQs
Q1: How do I choose between DOS30, DOS45 and DOS60?
Start by comparing chamber capacity, internal dimensions, sample quantity and available space. DOS30 is 30 L, DOS45 is 72 L and DOS60 is 150 L. If space is limited or samples are large, check both internal and external dimensions.
Q2: What applications are DOS precision ovens suited for?
Typical applications include laboratory sample drying, material pre-treatment, quality-control inspection, research testing and small-scale process heating.
Q3: How does the DOS series differ from large hot-air circulation equipment?
The DOS series is geared toward laboratory, R&D and quality-control sample drying, with a focus on small to medium samples, chamber capacity and temperature control. For larger workpieces, production-line drying or batch baking, consider other hot-air circulation equipment.
Q4: What information should I provide when requesting a quote?
Provide sample dimensions, batch quantity, target temperature, drying time, available power, installation space and any special process requirements to help assess the suitable capacity and model.
Q5: Does Fulcrum Technology provide demonstrations, stock checks and repair service?
Fulcrum Technology can help arrange equipment demonstrations, check stock and lead times, and provide after-sales technical support and repair service, depending on the product. Confirm service availability for the specific model and application.
Need help choosing the right DOS30, DOS45 or DOS60?
Share the sample dimensions, batch quantity, target temperature, drying time, available power and application. Fulcrum Technology can help assess the options based on product information and your requirements.