Spectrophotometer TS10
TS10 Spectrophotometer | 8 mm Aperture, Lab Color Data and Routine Color Difference Checks
TS10 SpectrophotometerTh e portable TS10 spectrophotometer supports Lab color data and ΔE color-difference evaluation, incoming inspection, process checks, and routine color quality control. It suits applications that need fast on-site color comparison, basic color records, and batch-difference decisions.
With a Φ8 mm aperture, 10° observer angle, combined full-spectrum LED source, and planar-grating optics, TS10 supports routine QC for plastics, coatings, inks, textiles, printing, packaging, and general manufacturing. If you need extensive standard/sample retention, supplier batch records, or a broader QC software workflow, compare TS20 Spectrophotometer. Confirm the sample size, surface, measurement area, gloss, data-management needs, and internal QC workflow before selecting a model.
TS10 Spectrophotometer Features
Designed for 8 mm aperture measurements, Lab data, color-difference evaluation, on-site inspections, and routine QC recordkeeping.
Φ8 mm Measurement Aperture
The TS10 Φ8 mm aperture and 10° observer angle suit many samples with a general measurement area, flat materials, and routine color comparisons.
Full-Spectrum LED and Grating Optics
The combined full-spectrum LED source and planar-grating spectrometer, paired with a full-color capacitive touchscreen, support quick on-site operation and QC data review.
Dual 24-Element Sensor Array
Its dual-row, 24-element silicon photodiode array supports routine color-difference checks, batch comparisons, and basic color records.
On-Site Inspection and Rapid Comparison
Suitable for incoming inspection, process checks, spot sampling, and routine QC, helping operators quickly obtain Lab data and color-difference results.
Standard and Sample Data Storage
It can serve as a basic tool for retaining standard and sample data and comparing batches in routine QC workflows that require basic color inspection records.
How to Distinguish TS10 and TS20
Both TS10 and TS20 are portable spectrophotometers. Do not choose based on SCI alone; consider inspection frequency, data-retention needs, batch QC workflows, and software requirements.
TS10 | Fast On-Site Comparison and Routine QC
If your needs center on a Φ8 mm aperture, preliminary incoming checks, on-site inspections, Lab color data, ΔE evaluation, and basic batch comparison, start by evaluating TS10 Spectrophotometer. Confirm sample area, surface condition, and acceptance criteria for your application.
TS20 | Standard/Sample Retention and QC Data Management
If you need more frequent batch comparisons, standard/sample retention, supplier acceptance records, or more comprehensive QC data management, also compare TS20 Spectrophotometer. Verify the software functions, data-retention method, and supplied version.
TS10 Spectrophotometer FAQs
Answers to common questions about TS10, its 8 mm aperture, routine color-difference checks, Lab data, and comparison with TS20.
Which routine QC applications suit TS10?
TS10 suits incoming inspection, process checks, spot sampling, preliminary R&D sample comparisons, and general batch color-difference decisions. If you need a basic Lab and ΔE evaluation workflow, consider TS10; confirm sample conditions and acceptance criteria.
What samples suit the 8 mm aperture?
The Φ8 mm aperture generally suits samples with sufficient flat measurement area, such as plastic parts, coated surfaces, paper, packaging, textile swatches, and manufactured parts. For small samples, pronounced curves, or constrained measurement spots, provide sample details to confirm whether another aperture is needed.
How should TS10 and TS20 be compared?
TS10 prioritizes fast on-site comparison, basic color records, and routine inspections. Consider TS20 when you need more extensive standard/sample retention, batch traceability, or QC data management. Verify actual differences against product specifications, data needs, and the supplied version.
Is TS10 suitable for supplier incoming inspection?
TS10 can support supplier batch color comparisons and basic color records. If acceptance requires extensive standard management, long-term traceability, report exports, or cross-team data integration, also evaluate TS20 or another model with stronger data-management capabilities.
What information should you provide before adopting TS10?
Provide the sample material and dimensions, spot size, surface gloss, texture or curvature, color-difference formula, viewing conditions, acceptance criteria, inspection frequency, and any standard/sample retention needs to confirm whether TS10 fits your QC workflow.
Can TS10 replace visual color assessment?
TS10 provides Lab data and ΔE evaluation to help reduce subjectivity in visual-only judgments. Actual QC criteria should also reflect appearance requirements, customer acceptance conditions, lighting, and internal tolerances.
Checks Before Adoption
For small, curved, textured, or gloss-variable samples, multiple batches, or multiple suppliers, first share sample conditions, inspection goals, and internal criteria. Then confirm that the TS10 Φ8 mm aperture, measurement conditions, data-retention needs, and QC workflow fit on-site use.
Contact Fulcrum Technology for Selection AdviceTS10 Spectrophotometer Technical Specifications
Use this specification table as a reference when evaluating the TS10 for routine color inspection and quality control. Confirm the supplied configuration and suitability against the actual sample and application.
| Specification | TS10 |
|---|---|
| Model | TS10 handheld spectrophotometer |
| Light source | Combined full-spectrum LED source |
| Spectral dispersion | Plane grating |
| Sensor | Silicon photodiode array, dual row with 24 groups |
| Wavelength range | 400–700 nm |
| Wavelength interval | Not specified (shown as “/” in manufacturer data) |
| Spectral bandwidth | 10 nm |
| Reflectance measurement | L: 0–100; reflectance measured at one user-selected wavelength (default 550 nm) |
| Measurement aperture | Φ8 mm |
| Specular component | SCI |
| Color spaces | CIE LAB, XYZ, Yxy and LCh |
| Color-difference formulas | ΔE*ab and ΔE*00 |
| Other colorimetric indices | Not specified in manufacturer data |
| Observer angle | 10° |
| Illuminants | D65, A and F2 (CWF) |
| Displayed data | Reflectance at one user-selected wavelength, sample color values, color-difference values/chart, pass/fail result, color simulation and color offset |
| Display resolution | 0.01 |
| Measurement time | Approx. 1.5 seconds |
| Repeatability | MAV/SCI, ΔE*ab ≤ 0.1; average of 30 white-tile readings at 5-second intervals after white calibration |
| Inter-instrument error | MAV/SCI, ΔE*ab ≤ 0.4; average across 12 BCRA Series II color tiles |
| Measurement mode | Single or average measurement (2–99 readings) |
| Positioning method | Stabilizer cross positioning |
| Dimensions (L × W × H) | 81 × 71 × 214 mm |
| Weight | Approx. 460 g |
| Battery | Li-ion battery; up to 6,000 measurements within 8 hours (manufacturer specification) |
| Light-source life | 5 years; more than 3 million measurements |
| Display | 3.5-inch TFT color LCD with capacitive touchscreen |
| Data port | USB for charging only; not compatible with PC software |
| Data storage | 500 standards; 10,000 samples |
| Languages | Simplified Chinese, English and Traditional Chinese |
| Operating environment | 0–40 °C; 0–85% RH, non-condensing; altitude below 2,000 m |
| Storage environment | −20–50 °C; 0–85% RH, non-condensing |
| Standard accessories | Power adapter, USB cable, user guide, white-and-black calibration cavity, protective cover, wrist strap and Φ8 mm flat aperture |
| Optional accessories | USB micro printer and powder test box |
Specification note: Manufacturer technical parameters are for reference and may vary by supplied version; confirm the actual product and accessories before purchase.