Dual-row 20-element sensor array
The large-area silicon photodiode array uses two rows of 20 elements to support routine color measurement, batch comparison and quality-control records.
Designed for D/8 SCI/SCE color comparison, a 400–700 nm full-spectrum LED source, camera targeting and routine color-quality data management.
The large-area silicon photodiode array uses two rows of 20 elements to support routine color measurement, batch comparison and quality-control records.
D/8 illumination and viewing geometry supports SCI/SCE and simultaneous fast SCI+SCE measurement for comparison with and without the specular component.
The 400–700 nm full-spectrum LED source, together with UV illumination, can be considered for general materials and initial assessment of some fluorescent samples. Confirm conditions against the sample and inspection purpose.
The built-in camera helps operators place the measurement point on the target area, supporting local color-difference checks and repeatable positioning.
A non-contact automatic calibration workflow with a standard white tile helps maintain consistent daily measurement conditions. Follow the manufacturer instructions for calibration method and frequency.
The placement base helps protect the white tile and instrument contact surface from contamination during routine handling and calibration.
Supports CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy, DIN Lab99 and Munsell color spaces, with multiple illuminants for color comparison.
Workflows can include spectral reflectance, whiteness, yellowness, metamerism, colorfastness, color strength, opacity and color-density records. Confirm software support for specific functions.
Depending on the supplied software configuration, Windows and mobile workflows can support color-data organization, batch comparison and on-site quality records.
For small, curved, textured, glossy or fluorescent samples, confirm sample condition, aperture, SCI/SCE requirements, acceptance criteria and data workflow before selection.
Use these specifications as a reference for ST50 selection and quality-control planning. Confirm sample conditions and workflow before finalizing the configuration.
| Specification | Details |
|---|---|
| Product model | ST50 Spectrophotometer |
| Measurement geometry | D/8 (diffuse illumination, 8° directional reception); SCI/SCE; conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164 and DIN 5033 Part 7 |
| Detector | Silicon photodiode array (two rows of 20 elements) |
| Spectral method | Planar grating |
| Integrating sphere diameter | Φ40 mm |
| Illumination source | Combined full-spectrum LED source |
| Wavelength range | 400–700 nm |
| Illuminants | D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30), B, U35, NBF, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, LED-C2, LED-C3 and LED-C5 |
| Resolution | 0.01 |
| Wavelength interval | 10 nm |
| Reflectance range | 0–200% |
| Measurement aperture | Φ8 mm or Φ4 mm |
| Measurement mode | SCI / SCE |
| Color spaces | CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy, DIN Lab99, Munsell (C/2) |
| Color-difference formulas | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE (Hunter) |
| Other colorimetric indicators | Spectral reflectance; WI (ASTM E313, CIE/ISO, AATCC, Hunter, Taube-Berger-Stensby); YI (ASTM D1925, ASTM 313); metamerism index Mt; staining and colorfastness; color strength; opacity; 8° gloss; 555 hue classification; blackness (My, dM); CMYK (A, T, E, M); tint; color density; Munsell |
| Standard observer | 2° / 10° |
| Display | Spectral graph / data, sample colorimetric values, color difference / graph, pass / fail result, color simulation, color bias |
| Measurement time | Approx. 1.5 seconds |
| Repeatability | Spectral reflectance: standard deviation within 0.1% (within 0.2% at 400–700 nm); colorimetric value: ΔE*ab within 0.03 (average of 30 white-tile measurements at 5-second intervals after calibration) |
| Inter-instrument difference | ΔE*ab within 0.2 (average across 12 BCRA Series II color tiles) |
| Measurement method | Single measurement or average measurement (2–99 readings) |
| Positioning | CCD targeting / stabilizer positioning |
| Dimensions | 129 × 76 × 217 mm (H × W × D) |
| Weight | 600 g |
| Battery | Rechargeable lithium battery |
| Illumination source life | Approx. 5 years; more than 1.5 million measurements |
| Display screen | 3.5-inch TFT full-color capacitive touchscreen |
| Interfaces | USB, Bluetooth 5.0 |
| Data storage | 1,000 standards and 30,000 samples (each record can include both SCI / SCE) |
| Software support | Windows |
| Languages | Traditional Chinese, Simplified Chinese, English |
| Operating temperature | 0–40°C; 0–85% RH (non-condensing) |
| Storage temperature | -20–50°C (non-condensing) |
| Standard accessories | Power adapter, data cable, user manual, black/white calibration box, protective cap, wrist strap, Φ8 mm or Φ4 mm aperture |
| Optional accessories | Mini printer, powder test box |
ST50 | Product Overview
The 3nh ST50 is a handheld spectrophotometer with a single configurable measurement aperture and D/8 geometry. It supports SCI/SCE measurement for color data, ΔE comparison and reflectance analysis across routine inspection and production workflows.
Use it to check plastics and electronics, paints and inks, textiles, printing and ceramics. Before selecting an aperture or configuration, confirm the sample size, surface, measurement location and inspection requirements.
Compare color with the specular component included or excluded, with simultaneous SCI/SCE measurement support.
Choose the listed Φ8 mm or Φ4 mm aperture according to sample dimensions and the target measurement area.
Supports common color spaces and ΔE formulas for material comparison, incoming checks and batch quality records.