YL3120 Non-Contact Spectrophotometer | Inline Color Sensor

YL3120 non-contact spectrophotometer uses 45/0 geometry as an inline color sensor for production lines, robotic stations and automated quality control. It can be evaluated for liquids, wet films, pastes, powders, gels and delicate surfaces where probe contact may contaminate or mark the sample.Interfaces include RS485, USB, Ethernet, external trigger and analog output options. Confirm the sample, stable measurement distance, line speed, installation, communication and acceptance criteria before integration.

YL3120 Non-Contact Spectrophotometer for Inline Color Sensing

The YL3120 non-contact spectrophotometer uses 45/0 geometry for color monitoring on production lines, robotic stations and automated inspection systems. Its non-contact probe can be evaluated for liquids, wet films, pastes, powders, gels and delicate surfaces where touching a sample could cause transfer, contamination, indentation or scratching. Confirm suitability with representative samples and the actual line conditions.

As an inline color sensor, YL3120 can provide color data for process monitoring and quality workflows. Interfaces include RS485, USB, Ethernet, external trigger and analog output options. The exact connection and data workflow depend on the supplied configuration and the surrounding equipment.

45/0 inline color measurement

The 45/0 optical arrangement is intended for color measurement under controlled geometry. Fixed instrument mounting, a stable sample-to-probe distance, controlled ambient light, repeatable positioning and a defined calibration routine help establish a consistent process. For moving samples, assess line speed, trigger location, acquisition frequency, data return and the acceptable color limits together.

Non-contact measurement for special samples

YL3120 can be considered for liquids, wet coatings, pastes, powders, gels and surfaces that are vulnerable to contact. Flowing, uneven or height-varying samples need a suitable measurement window and stable positioning. Highly reflective, matte, translucent or heterogeneous materials should be evaluated at representative points and in a repeatable orientation.

Automation and system integration

RS485, USB and Ethernet may be used to assess connections with a PLC, host computer, MES or other production equipment. Confirm protocol, data format, trigger logic and control responsibilities before integration. API or database exchange, alarms, closed-loop adjustment and automatic production-parameter changes are project-specific functions that require engineering review of the equipment, data flow and safety logic.

Typical evaluation scenarios

  • Inline monitoring of color changes and batch differences during continuous production.
  • Robot or fixture-based inspection with a defined measuring point and distance.
  • Non-contact color measurement of wet films, liquids, pastes, powders, gels or delicate surfaces.
  • Recording color data for a host computer, MES or quality system.

Potential industries include anodizing, paints and coatings, paper, automotive paint lines, textiles, plastics, electronics and cosmetics. The sample and process should be tested before a production decision.

Installation planning

Before deployment, document the sample material and surface, whether it moves, measurement distance, line speed, trigger position, mounting space, ambient conditions, communication interface, calibration routine, output format and internal acceptance limits. Include fixtures, protection, maintenance access and an operating SOP in the site plan.

YL3120 selection questions

Can it be mounted on a conveyor or robot? Installation can be assessed for a conveyor, fixture, inspection station or robot. Confirm the measurement point, sample motion, stable distance and available space.

Can it measure liquids or powders? These samples may be considered for non-contact measurement. Keep the sample location and measuring distance stable, and check the measuring window for flowing or uneven material.

Can it connect to a PLC or MES? Interfaces can support an integration assessment. Custom exchanges with PLC, MES, databases or APIs must be checked against the site architecture, data format and control requirements.

Can readings control production automatically? Measurement and data output do not by themselves establish closed-loop control. Alarms or changes to machine parameters require a separately designed and validated system.

Compare the YL3160 non-contact spectrophotometer for related inline applications, or browse the non-contact spectrophotometer range. For an application review, contact Fulcrum Technology with sample photos, line speed, mounting space and communication requirements.


YL3120 Non-Contact Spectrophotometer Specifications

Use these specifications as a reference for selection and line integration. Confirm sample behavior, distance stability, line speed, interfaces, customization and acceptance criteria for the actual configuration.

ItemSpecification
ModelYL3120
ProductNon-contact spectrophotometer
Geometry45/0 (45° annular illumination, 0° viewing)
StandardsCIE No.15; GB/T 3978; GB 2893; GB/T 18833; ISO 7724-1; ASTM E1164; DIN 5033 Teil 7
Measurement principleNon-contact; for liquids, pastes, powders, wet films and delicate surfaces
IlluminationFull-spectrum LED
SpectrometerConcave grating
Sensor256-pixel dual-array CMOS image sensor
Wavelength range400–700 nm
Wavelength interval10 nm
Display precision0.01
Reflectance resolution / range0.01% / 0–200%
Measurement apertureΦ8 mm
Non-contact distance7.5 mm (±0.15 mm)
Sample thicknessNo thickness limit; measurement uses the probe
ObservationVisual
Measurement interval1 second
Trigger modesInstrument trigger or online control trigger
Color spacesCIE LAB, XYZ, Yxy, LCh, CIE LUV, Munsell, s-RGB, Hunter Lab, βxy, DIN Lab99
Color difference formulasΔE*ab, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, ΔE (Hunter), DIN ΔE99
Other color indicesSpectral reflectance, WI, Tint, YI, MI, staining and color fastness, strength, opacity, blackness (My, dM), CMYK density; some functions require host software
Observer angles2° / 10°
IlluminantsA, B, C, D50, D55, D65, D75, F1–F12, CWF, U30, U35, DLF, NBF, TL83, TL84, ID50, ID65, LED-B1–B5, LED-BH1, LED-RGB1, LED-V1, LED-V2
DisplayData, sample color values, color differences/graphs, color simulation, pass/fail; tolerance can be set
Measurement timeFastest 0.05 s; typical approximately 0.1 s
CalibrationIntelligent automatic calibration
ProtectionIP66
RepeatabilityΔE*ab ≤0.03 under the best test mode at a 1.0 s single-measurement time; after warm-up, average of 30 white-board readings at 5 s intervals
Inter-instrument differenceΔE*ab ≤0.3 (average across 12 BCRA Series II color tiles)
Measurement modesSingle or average measurement (2–99 readings)
Dimensions / weight100 × 100 × 140 mm / approx. 1,400 g
PowerDC 24 V, 3 A supply
Light-source life5 years or more than 3 million measurements
Display screen3.5-inch TFT color screen
InterfacesUSB, RS485, RS232, Ethernet, external trigger, analog output
LanguagesSimplified Chinese, Traditional Chinese, English
Operating environment0–40°C; 0–85% RH, non-condensing; altitude below 2,000 m
Storage environment−20–50°C; 0–85% RH, non-condensing
Standard accessoriesUSB cable, RJ45 cable, RS485 multi-unit cable, RS232 cable, standard calibration board, black calibration box
NotesDesigned primarily for production-line use. Custom functions may incur additional fees; confirm scope, cost and implementation. Specifications may change; verify current details with Fulcrum Technology.

Selection reminder: Confirm sample and surface condition, fixed measurement distance, line speed, trigger, mounting space, communication, host software, output format, customization and acceptance limits. PLC, MES, database or real-time decision integration should be reviewed by an engineer.