NH300 Horizontal Colorimeter (Φ8 mm Aperture)

The NH300 is a handheld Φ8 mm colorimeter with D/8 geometry and SCI mode for routine color checks. It is suitable for plastics, electronics, paints and inks, textiles, printing and paper, food, pharmaceuticals, cosmetics, research and laboratories, and supports onboard sample storage with CQCS3 quality-management software.

Product Introduction

NH300 Horizontal Colorimeter | Single 8 mm Aperture for Routine Color Checks

NH300 horizontal colorimeteris a handheld 3nh colorimeter for routine quality control. Its D/8 geometry, Φ8 mm aperture and LED illumination support CIE Lab, LCh and XYZ data and ΔE*ab evaluation for incoming inspection, in-process checks, standard-to-sample comparisons, basic lab quality control and quick on-site checks.

The NH300 is designed for straightforward operation, stable measurement and economical routine color checks. The manufacturer lists a multi-channel color sensor, IC platform, color algorithms, automatic black/white calibration at startup, light-spot positioning, CQCS3 software and a rechargeable lithium battery. Confirm the fit against the material, surface condition, measurement area, color uniformity and quality-control workflow.

Key Features

NH300 colorimeter features

For businesses that need quick color comparison, routine quality control and checks at the point of use.

01

D/8 geometry for routine color comparison

NH300 uses D/8 geometry to compare colors between a standard and a test sample. It reports CIE Lab, LCh and XYZ and supports ΔE*ab for routine quality-control checks.

For glossy, directional-textured, transparent, translucent or unevenly colored samples, first confirm the measurement conditions, sample fixture and internal acceptance criteria.

02

Single Φ8 mm measurement aperture for specimens with a consistent measurement area

The Φ8 mm aperture suits samples with adequate measurement area, a relatively flat surface and a fixed test location, such as plastic housings, painted parts, packaging, paper, fabrics, inks and general industrial materials.

For small samples, hard-to-align points or applications requiring a Φ4 mm aperture and camera positioning, consider the NH310 horizontal colorimeter。

03

Automatic black and white calibration at startup

Automatic startup calibration helps complete the basic calibration procedure before measurement and reduces the chance of missing this step.

When operators share a unit or work across shifts, or where a documented quality-control procedure is in place, define white-tile storage, calibration intervals, pre-measurement checks and data recording to improve consistency.

04

Light-spot positioning for quick measurement setup

Light-spot positioning helps identify the measurement area quickly during production checks, incoming inspection, sample comparisons and routine laboratory checks.

Compared with camera positioning, light-spot positioning suits samples with a clearly defined location and an adequate area. For small local measurement points, confirm whether finer positioning is needed.

05

Measurement stability for routine quality checks

The manufacturer lists Φ8 mm repeatability within ΔE*ab 0.07, based on the mean of 30 white-tile measurements taken at 5-second intervals after warm-up and calibration. Use this figure as a reference when evaluating routine color comparison and quality-control checks.

Actual results depend on the sample surface, measurement position, ambient light, calibration and operator procedure. Verify with actual samples before adopting the instrument.

06

CQCS3 quality-management software

NH300 can be used with CQCS3 for color-difference analysis, cumulative analysis, viewing colorimetric indices, managing sample libraries and simulating colors. It supports workflows that require reference samples, batch records or tracking of color differences.

For custom reports, ERP/MES connections, database integration or automated judgments, have an engineer review the existing system and requirements.

07

Rechargeable lithium battery for on-site checks

NH300 uses a rechargeable lithium-ion battery. The manufacturer lists more than 5,000 measurements per charge. It is suited to color checks on production lines, in warehouses, at suppliers and at customer sites.

Actual battery life depends on battery condition, screen brightness, measurement frequency and the operating environment.

Application

Typical NH300 applications

Incoming inspection

For initial color comparisons between a reference and incoming supplier materials.

In-process checks

For quickly checking whether production batch colors deviate from internal standards.

Laboratory quality control

For routine checks that require basic CIE Lab and ΔE*ab results.

Sample comparison

For checking differences between customer samples, standards, test samples and prototypes.

Selection Guide

Choosing between the NH300 and NH310

RequirementNH300NH310
Measurement apertureSingle Φ8 mm aperture for samples with adequate area and a fixed test location.Dual Φ4 mm and Φ8 mm apertures for routine samples and small test points.
PositioningLight-spot positioning to identify the measurement area quickly.Alignment and camera positioning for small areas or specified measuring points.
Primary applicationsEconomical routine color comparison, incoming inspection and in-process checks.Small-area positioning, dual-aperture applications and more flexible sample comparisons.
Selection noteConsider NH300 for samples with a consistent area and a simple workflow.Consider NH310 if samples are small, test points are difficult to align, or two apertures are required.

What to confirm before use

NH300 is suitable for economical color comparison, incoming inspection, in-process checks and routine quality control. Confirm the material, gloss, texture direction, whether the sample covers the Φ8 mm aperture, the internal acceptance criteria and calibration procedure. Depending on your requirements for small-area positioning, two apertures, full spectral data, multiple illuminants or supply-chain color traceability, consider NH310 or a handheld spectrophotometer。

Contact Fulcrum Technology to discuss your NH300 application

 

NH300 Technical Specifications

Use these specifications to confirm the measurement conditions and application fit. Verify sample dimensions and the applicable acceptance standard before selecting a configuration.

ItemSpecification
ModelNH300 Colorimeter
Measurement geometryD/8 (diffuse illumination, 8° viewing, including specular component SCI); complies with CIE No. 15 and GB/T 3978
DetectorSilicon photodiode array
Spectral separationN/A
Integrating sphere sizeΦ40 mm
Illumination sourceFull-spectrum LED light source
Measurement wavelength rangeN/A
Observer illuminantsD65
Wavelength intervalN/A
Reflectance measurement rangeN/A
Measurement apertureΦ8 mm
Measurement modeSCI
Color spacesCIE LAB, XYZ, LCh
Color difference formulaΔE*ab
Other color indicesN/A
Observer angle10°
Displayed parametersSample color values, color difference, pass/fail result and color bias
Measurement timeApprox. 1.5 seconds
RepeatabilityΔE*ab ≤ 0.07 (after warm-up and calibration; average of 30 white-board measurements at 5-second intervals)
Inter-instrument differenceΔE*ab ≤ 0.4 (average of 12 BCRA Series II color-tile measurements)
Measurement modeSingle measurement
Positioning methodAlignment positioning
Dimensions205 × 70 × 100 mm
WeightApprox. 400 g
BatteryRechargeable lithium battery
Light-source lifetimeApprox. 5 years or more than 1.6 million measurements
Display2.8-inch color TFT display
InterfaceUSB
Data storage100 standard samples and 20,000 test samples
Software supportCQCS3 quality-management software
LanguagesTraditional Chinese, Simplified Chinese and English
Operating conditions0–40°C; 0–85% relative humidity (non-condensing)
Storage temperature-20–50°C (non-condensing)
Standard accessoriesPower adapter, user manual, white calibration box, data cable, quality-management software (download from the official website), Φ8 mm aperture and lithium battery
Optional accessoriesMini printer, powder test box and multifunctional test component

Specifications may vary by product version. Please confirm the latest information with Fulcrum Technology before ordering.