NH300 Horizontal Colorimeter (Φ8 mm Aperture)
NH300 Horizontal Colorimeter | Single 8 mm Aperture for Routine Color Checks
NH300 horizontal colorimeteris a handheld 3nh colorimeter for routine quality control. Its D/8 geometry, Φ8 mm aperture and LED illumination support CIE Lab, LCh and XYZ data and ΔE*ab evaluation for incoming inspection, in-process checks, standard-to-sample comparisons, basic lab quality control and quick on-site checks.
The NH300 is designed for straightforward operation, stable measurement and economical routine color checks. The manufacturer lists a multi-channel color sensor, IC platform, color algorithms, automatic black/white calibration at startup, light-spot positioning, CQCS3 software and a rechargeable lithium battery. Confirm the fit against the material, surface condition, measurement area, color uniformity and quality-control workflow.
NH300 colorimeter features
For businesses that need quick color comparison, routine quality control and checks at the point of use.
D/8 geometry for routine color comparison
NH300 uses D/8 geometry to compare colors between a standard and a test sample. It reports CIE Lab, LCh and XYZ and supports ΔE*ab for routine quality-control checks.
For glossy, directional-textured, transparent, translucent or unevenly colored samples, first confirm the measurement conditions, sample fixture and internal acceptance criteria.
Single Φ8 mm measurement aperture for specimens with a consistent measurement area
The Φ8 mm aperture suits samples with adequate measurement area, a relatively flat surface and a fixed test location, such as plastic housings, painted parts, packaging, paper, fabrics, inks and general industrial materials.
For small samples, hard-to-align points or applications requiring a Φ4 mm aperture and camera positioning, consider the NH310 horizontal colorimeter。
Automatic black and white calibration at startup
Automatic startup calibration helps complete the basic calibration procedure before measurement and reduces the chance of missing this step.
When operators share a unit or work across shifts, or where a documented quality-control procedure is in place, define white-tile storage, calibration intervals, pre-measurement checks and data recording to improve consistency.
Light-spot positioning for quick measurement setup
Light-spot positioning helps identify the measurement area quickly during production checks, incoming inspection, sample comparisons and routine laboratory checks.
Compared with camera positioning, light-spot positioning suits samples with a clearly defined location and an adequate area. For small local measurement points, confirm whether finer positioning is needed.
Measurement stability for routine quality checks
The manufacturer lists Φ8 mm repeatability within ΔE*ab 0.07, based on the mean of 30 white-tile measurements taken at 5-second intervals after warm-up and calibration. Use this figure as a reference when evaluating routine color comparison and quality-control checks.
Actual results depend on the sample surface, measurement position, ambient light, calibration and operator procedure. Verify with actual samples before adopting the instrument.
CQCS3 quality-management software
NH300 can be used with CQCS3 for color-difference analysis, cumulative analysis, viewing colorimetric indices, managing sample libraries and simulating colors. It supports workflows that require reference samples, batch records or tracking of color differences.
For custom reports, ERP/MES connections, database integration or automated judgments, have an engineer review the existing system and requirements.
Rechargeable lithium battery for on-site checks
NH300 uses a rechargeable lithium-ion battery. The manufacturer lists more than 5,000 measurements per charge. It is suited to color checks on production lines, in warehouses, at suppliers and at customer sites.
Actual battery life depends on battery condition, screen brightness, measurement frequency and the operating environment.
Typical NH300 applications
Incoming inspection
For initial color comparisons between a reference and incoming supplier materials.
In-process checks
For quickly checking whether production batch colors deviate from internal standards.
Laboratory quality control
For routine checks that require basic CIE Lab and ΔE*ab results.
Sample comparison
For checking differences between customer samples, standards, test samples and prototypes.
Choosing between the NH300 and NH310
| Requirement | NH300 | NH310 |
|---|---|---|
| Measurement aperture | Single Φ8 mm aperture for samples with adequate area and a fixed test location. | Dual Φ4 mm and Φ8 mm apertures for routine samples and small test points. |
| Positioning | Light-spot positioning to identify the measurement area quickly. | Alignment and camera positioning for small areas or specified measuring points. |
| Primary applications | Economical routine color comparison, incoming inspection and in-process checks. | Small-area positioning, dual-aperture applications and more flexible sample comparisons. |
| Selection note | Consider NH300 for samples with a consistent area and a simple workflow. | Consider NH310 if samples are small, test points are difficult to align, or two apertures are required. |
What to confirm before use
NH300 is suitable for economical color comparison, incoming inspection, in-process checks and routine quality control. Confirm the material, gloss, texture direction, whether the sample covers the Φ8 mm aperture, the internal acceptance criteria and calibration procedure. Depending on your requirements for small-area positioning, two apertures, full spectral data, multiple illuminants or supply-chain color traceability, consider NH310 or a handheld spectrophotometer。
Contact Fulcrum Technology to discuss your NH300 applicationNH300 Technical Specifications
Use these specifications to confirm the measurement conditions and application fit. Verify sample dimensions and the applicable acceptance standard before selecting a configuration.
| Item | Specification |
|---|---|
| Model | NH300 Colorimeter |
| Measurement geometry | D/8 (diffuse illumination, 8° viewing, including specular component SCI); complies with CIE No. 15 and GB/T 3978 |
| Detector | Silicon photodiode array |
| Spectral separation | N/A |
| Integrating sphere size | Φ40 mm |
| Illumination source | Full-spectrum LED light source |
| Measurement wavelength range | N/A |
| Observer illuminants | D65 |
| Wavelength interval | N/A |
| Reflectance measurement range | N/A |
| Measurement aperture | Φ8 mm |
| Measurement mode | SCI |
| Color spaces | CIE LAB, XYZ, LCh |
| Color difference formula | ΔE*ab |
| Other color indices | N/A |
| Observer angle | 10° |
| Displayed parameters | Sample color values, color difference, pass/fail result and color bias |
| Measurement time | Approx. 1.5 seconds |
| Repeatability | ΔE*ab ≤ 0.07 (after warm-up and calibration; average of 30 white-board measurements at 5-second intervals) |
| Inter-instrument difference | ΔE*ab ≤ 0.4 (average of 12 BCRA Series II color-tile measurements) |
| Measurement mode | Single measurement |
| Positioning method | Alignment positioning |
| Dimensions | 205 × 70 × 100 mm |
| Weight | Approx. 400 g |
| Battery | Rechargeable lithium battery |
| Light-source lifetime | Approx. 5 years or more than 1.6 million measurements |
| Display | 2.8-inch color TFT display |
| Interface | USB |
| Data storage | 100 standard samples and 20,000 test samples |
| Software support | CQCS3 quality-management software |
| Languages | Traditional Chinese, Simplified Chinese and English |
| Operating conditions | 0–40°C; 0–85% relative humidity (non-condensing) |
| Storage temperature | -20–50°C (non-condensing) |
| Standard accessories | Power adapter, user manual, white calibration box, data cable, quality-management software (download from the official website), Φ8 mm aperture and lithium battery |
| Optional accessories | Mini printer, powder test box and multifunctional test component |
Specifications may vary by product version. Please confirm the latest information with Fulcrum Technology before ordering.