LS129 UV Irradiance Meter Module

The LS129 UV irradiance meter module is a digital probe for integrating UV intensity and energy measurement into equipment, production lines and automation systems. Its detector and controller are separate, and it supports RS485 communication with the MODBUS protocol for connection to a PLC, PC or HMI. Applications include UV curing, UV LED source monitoring, UVC germicidal equipment and process monitoring. UVALED, UVA and UVC spectrum versions are available; confirm the source center wavelength, power range, installation space, power supply and communication requirements before selection.

LS129 UV Irradiance Meter Module

UV Monitoring for Equipment Integration and Online Measurement

The LS129 is a digital UV probe module designed to integrate UV intensity and energy monitoring into equipment, production lines and automation systems. It uses RS485 communication with the MODBUS protocol. The detector and controller are separate for flexible installation and can connect to a PC, PLC or HMI. Typical applications include UV curing equipment, UV LED sources, UVC germicidal equipment and automated process monitoring. Confirm the spectrum, irradiance range, mounting space, communication needs and control system before selection.

01

Probe Design and Installation

The digital probe module can be fixed inside equipment or at a production-line measurement point to monitor UV intensity and energy.

Exterior structure of the LS129 UV irradiance meter module for equipment integration and online UV monitoring
02

Spectrum Versions

UVALED, UVA and UVC versions are available for different source bands. Confirm the source center wavelength, power range and measurement purpose before selecting a version.

Spectral response curve for LS129 UVALED, UVA and UVC versions
03

Separate Detector and Controller

The detector and controller can be positioned separately to suit equipment space and measurement location, or mounted together when the installation requires it.

LS129 digital UV probe with separate detector and controller for flexible installation
04

RS485 / MODBUS Online Monitoring

Set the communication address and baud rate to connect multiple devices and read data through a PLC, PC or HMI. For continuous monitoring, consider equipment temperature, cable routing and site conditions during installation.

LS129 supports RS485 MODBUS connection to PLC, PC and HMI systems
05

DC 5–24 V Power Supply

The LS129 operates from DC 5–24 V for industrial equipment and automation integration. Verify the actual supply and wiring against the control system and site electrical plan.

LS129 supports a DC 5 to 24 V supply for industrial equipment integration
06

PC Commissioning Software

PC test software can support protocol commissioning, data reading and configuration checks. PLC, HMI or database integration may require engineering development for the actual system.

Commissioning support for system integration

LS129 Communication Parameters

01 · Address

MODBUS address 1 is the default and can be changed with the commissioning tool or protocol settings. Adjustable address range: 1–247.

02 · Baud Rate

Default baud rate: 9600 bps. Selectable rates: 4800, 9600, 19200 or 38400 bps.

03 · MODBUS

Read measurement data and configure the address and baud rate for PLC, PC or HMI integration.

Probe Wiring Reference

Wire colors may vary by production batch. Verify the supplied documentation or confirm with Fulcrum before wiring; do not rely on color alone.

Wire colorFunction
Black (with heat-shrink sleeve)Shield
RedPower positive (DC 5–24 V)
BlackPower negative
Green / blueRS485−
Yellow / whiteRS485+

Optional Commissioning Tools

The following tools are optional. Select them according to the integration method, control system and installation conditions, and confirm the quoted configuration.

01

Commissioning HMI

View probe data and set the communication address and baud rate for on-site commissioning.

Optional LS129 commissioning HMI for viewing probe data and setting communication parameters
02

RS232 / RS485 Converter

Support protocol commissioning between existing equipment and a computer.

Optional LS129 RS232 RS485 converter for protocol commissioning
03

USB Adapter

Convert RS485 to USB for PC data reading, engineering commissioning and initial integration tests.

Optional LS129 USB adapter for connecting the probe to a computer
Integration Notes

The LS129 is a UV irradiance meter module for equipment integration and online monitoring, not a general-purpose handheld inspection meter. For spot checks or field inspections, consider the LS125 multi-probe UV irradiance meter. For PLC, HMI or host-computer integration, assess protocol, power, mounting space and source spectrum. Contact Fulcrum for selection and system-integration guidance.

Software and Communication Resources

The LS129 supports RS485 and MODBUS and can be tested with commissioning tools or PC software. Contact Fulcrum to confirm the current software, protocol and wiring documentation version.

View LS129 software and support resources

LS129 Model Comparison

Choose the detector version according to the UV source spectrum and required measurement range. Specifications below are reference values; confirm the ordered version and current configuration before integration.

ParameterLS129-UVALEDLS129-UVALS129-UVC
Spectral response340–420 nm; calibrated at 395 nm315–400 nm; peak wavelength 365 nm230–280 nm; peak wavelength 254 nm
Typical applicationUV LED curing and 365–405 nm LED source monitoringUVA mercury lamps, exposure, aging and general UVA monitoringGermicidal lamps, 254 nm mercury lamps and disinfection equipment
Irradiance range0–20,000 mW/cm²0–2,000 mW/cm²0–200,000 μW/cm²
Energy range0–4×10⁹ mJ/cm²0–4×10⁹ mJ/cm²0–4×10⁹ μJ/cm²
Resolution1 mW/cm² / 0.1 mW/cm²0.1 mW/cm²0.1 μW/cm²
AccuracyH < 50: ±5 mW/cm²; H ≥ 50: ±10%HH < 5: ±0.5 mW/cm²; H ≥ 5: ±10%HH < 50: ±5 μW/cm²; H ≥ 50: ±10%H
Sampling rate2048/s2048/s6/s
Data refresh200 ms200 ms200 ms
ApertureΦ10 mmΦ10 mmΦ10 mm
Communication cable1 m; rated to 80°C1 m; rated to 80°C1 m; rated to 80°C
Detector cable0.5 m; rated to 200°C0.5 m; rated to 200°CNot applicable
Interface / protocolRS485 / MODBUSRS485 / MODBUSRS485 / MODBUS
Power supplyDC 5–24 V, 20 mADC 5–24 V, 20 mADC 5–24 V, 20 mA
Operating environment−25 to 85°C; <85% RH, non-condensing−25 to 85°C; <85% RH, non-condensing−25 to 85°C; <85% RH, non-condensing
Controller dimensions72.5×32×15.1 mm72.5×32×15.1 mm72.5×32×15.1 mm
Detector dimensions35×15×14.5 mm35×15×14.5 mm35×15×14.5 mm

H denotes the measured irradiance value. Confirm the source spectrum, range, calibration requirement, environmental conditions and product revision with Fulcrum before final selection.


Installation and Integration Overview

The LS129 is designed to be incorporated into UV equipment and production systems. Before installation, confirm the detector version matches the source spectrum, provide a stable DC 5–24 V supply, and plan the detector position, cable route and controller mounting location.

Commissioning Checklist

  1. Verify the ordered model (UVALED, UVA or UVC) and the applicable irradiance range.
  2. Check the wiring against the documentation supplied with the current production batch; wire colors can vary.
  3. Set a unique MODBUS address and a supported baud rate, then confirm communication with the PLC, PC or HMI.
  4. Compare readings with the intended operating conditions and establish the application's own alarm or process limits.

For spot measurements and field inspections, see the LS125 multi-probe UV irradiance meter. For system selection and integration questions, contact Fulcrum.

Software and Technical Support

Use the LS129 software and support resources for available setup materials. Confirm the current software and document revision with Fulcrum before commissioning. Final system design, alarm logic and connection to a database or host platform may require application engineering.

top