Ultrasonic Homogenizer | Cell Disruption, Emulsification and Dispersion

Developed in collaboration with Fulcrum Technology

Ultrasonic Homogenizers and Cell Disruptors

Developed in collaboration with Fulcrum Technology, these ultrasonic homogenization and cell disruption systems support biotechnology sample preparation, food, chemical, and materials research for cell disruption, extraction, emulsification, particle dispersion, and nanomaterial processing.

Ultrasonic energy is applied to liquid samples with probe and power configurations selected for sample volume, vessel size, and process goals. Options include separate-unit, benchtop, and reactor-vessel systems for laboratory space and equipment integration needs.

Compare systems by workspace and process needs

FTZ Separate-Unit Ultrasonic Homogenizer

Separate main unit for flexible laboratory layout

The main unit and processing unit are separate, allowing flexible placement in the lab. Suitable for sample preparation including cell disruption, extraction, emulsification, and material dispersion. Select power and probe by batch volume, vessel size, and process goal.

FT Benchtop Ultrasonic Homogenizer

For fixed workstations and routine sample processing

For routine sample processing and formulation tests at a fixed workstation, including cell disruption, emulsification, dispersion, and extraction. Select a probe for sample volume and vessel type, then establish operation time and cooling conditions.

FT Ultrasonic Vibration Rod

For reactor vessels and integration with existing equipment

For emulsification, dispersion, extraction, and homogenization with reactor vessels or existing equipment. Select power, probe, and rod length by vessel size, installation method, and sample volume. For recirculation or continuous processing, also plan flow rate, piping, and heat dissipation.

Provide sample and process details for a quotation

Provide batch volume, composition, viscosity, solids content, vessel dimensions, and the desired disruption, emulsification, or dispersion result. Also note temperature limits, cooling needs, and reactor or piping integration so the main unit, probe, and installation can be specified.

Local selection support in Taiwan | Application discussion | After-sales technical and repair support

Confirm equipment demonstrations, accessory configuration, stock, lead time, and service for the specific model and requirements.

FTZ separation ultrasonic homogenizer for cell disruption and emulsification
FTZ Separation Ultrasonic Homogenizer | 300–2,000 W
Fulcrum Technology | Co-developedFTZ Separation Ultrasonic HomogenizerFTZ Separation Ultrasonic Homogenizer | 300 W–2,000 WThe FTZ separation ultrasonic homogenizer, co-developed by Fulcrum Technology, combines ultrasonic homogenization and cell disruption. The series spans FTZ-300LI to FTZ-2000LI. Select a model according to processing volume, sample viscosity, application goals, output power, and booster size.300 W–2,000 WSelect power for sample volume and processing needsΦ3–Φ20 mmStandard boosters vary by modelVersatile sample processingCell disruption, emulsification, dispersion, extraction, and material pretreatmentFTZ Separation Ultrasonic Homogenizer SpecificationsFTZ models mainly differ in output power, standard booster size, and recommended processing volume. Start by screening for batch volume, then confirm the probe and model based on sample properties and processing objectives.ModelNet output powerStandard boosterProcessing volumeTypical applicationsFTZ-300LI300 WΦ3 mm0.1–100 mLTrace to small samples, cell disruption, initial trials, and small-volume dispersionFTZ-550LI550 WΦ6 mm0.1–500 mLSmall to medium samples, emulsification, dispersion, cell disruption, and extractionFTZ-650LI650 WΦ8 mm0.1–800 mLMedium-volume samples requiring higher energy for dispersion, emulsification, and mixingFTZ-950LI950 WΦ13 mm50–1,200 mLMedium-volume R&D trials, material dispersion, extraction, and sample pretreatmentFTZ-1200LI1,200 WΦ16 mm300–1,500 mLMedium to large samples, higher-viscosity materials, or more intensive processingFTZ-1500LI1,500 WΦ18 mm500–2,000 mLLarger processing volumes, material dispersion, emulsification, and scale-up trialsFTZ-2000LI2,000 WΦ20 mm500–3,000 mLHigh-power, large-volume samples and higher-intensity dispersionOptional booster sizes vary by application: FTZ-300LI supports Φ2 mm; FTZ-550LI supports Φ3 mm; FTZ-650LI supports Φ3 mm/Φ6 mm; FTZ-950LI supports Φ16 mm; FTZ-1200LI supports Φ13 mm; FTZ-1500LI supports Φ13 mm/Φ16 mm; and FTZ-2000LI supports Φ13 mm/Φ16 mm/Φ18 mm. Actual results also depend on sample viscosity, vessel dimensions, probe position, processing time, and temperature.How to Choose an FTZ Separation Ultrasonic HomogenizerDo not select a unit by power rating alone. Batch volume, sample properties, probe size, vessel dimensions, and processing goals all affect the right configuration.Trace to small samplesConsider the FTZ-300LI or FTZ-550LI, then confirm the booster based on actual sample volume and vessel size.Medium-volume samplesConsider the FTZ-650LI, FTZ-950LI, or FTZ-1200LI, and adjust the configuration for cell disruption, emulsification, dispersion, or extraction.Larger processing volumesDepending on sample conditions, consider the FTZ-1500LI or FTZ-2000LI for larger batches and higher energy requirements.For a quotation or model recommendation, provide: sample type, batch volume, viscosity or solids content, vessel dimensions, processing goal, temperature-control needs, and desired results.For guidance on power, probe size, and processing volume, read How to Choose an Ultrasonic Homogenizer: Power, Probe, Volume, and Price.FTZ Separation and FT Desktop SeriesFulcrum Technology also offers the FT desktop ultrasonic homogenizer series. If you are unsure whether to choose the separate FTZ system or an FT desktop model, compare their models, power, processing volumes, and configurations, then confirm against your sample requirements.View the FT desktop series →Not sure which model fits your sample?Emulsification, dispersion, cell disruption, and material processing require different conditions. Share your sample type and processing volume so we can recommend a suitable FTZ model and booster.Explore common ultrasonic homogenizer applications, or contact Fulcrum Technology with your sample details.#fulcrum-ftz-separation-homogenizer-2026 { color:#334155; font-size:15px; line-height:1.72; }#fulcrum-ftz-separation-homogenizer-2026 * { box-sizing:border-box; }#fulcrum-ftz-separation-homogenizer-2026 p { margin:0; }#fulcrum-ftz-separation-homogenizer-2026 a { color:#24658f; font-weight:700; text-decoration:none; }#fulcrum-ftz-separation-homogenizer-2026 a:hover { color:#174565; text-decoration:underline; }#fulcrum-ftz-separation-homogenizer-2026 h2,#fulcrum-ftz-separation-homogenizer-2026 h3 { color:#20384d; font-weight:800; }#fulcrum-ftz-separation-homogenizer-2026 h2 { margin:0; font-size:26px; line-height:1.35; }#fulcrum-ftz-separation-homogenizer-2026 h3 { margin:0 0 9px; font-size:19px; line-height:1.4; }#fulcrum-ftz-separation-homogenizer-2026 .product-intro { padding:22px; border:1px solid #dfe7ed; border-radius:8px; background:#f8fbfd; }#fulcrum-ftz-separation-homogenizer-2026 .brand-line { display:flex; align-items:center; gap:11px; margin-bottom:13px; padding-bottom:11px; border-bottom:1px solid #dfe7ed; }#fulcrum-ftz-separation-homogenizer-2026 .brand-logo { display:block; width:auto; max-width:115px; max-height:48px; height:auto; object-fit:contain; }#fulcrum-ftz-separation-homogenizer-2026 .brand-line span { color:#64748b; font-size:13px; font-weight:700; }#fulcrum-ftz-separation-homogenizer-2026 .eyebrow { margin-bottom:6px; color:#64748b; font-size:13px; font-weight:800; }#fulcrum-ftz-separation-homogenizer-2026 .lead { max-width:920px; margin-top:11px; color:#526170; }#fulcrum-ftz-separation-homogenizer-2026 .feature-row { display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px; margin-top:16px; }#fulcrum-ftz-separation-homogenizer-2026 .feature-item { padding:13px 14px; border:1px solid #dfe7ed; border-radius:7px; background:#fff; }#fulcrum-ftz-separation-homogenizer-2026 .feature-item strong,#fulcrum-ftz-separation-homogenizer-2026 .feature-item span { display:block; }#fulcrum-ftz-separation-homogenizer-2026 .feature-item strong { margin-bottom:3px; color:#20384d; font-size:16px; }#fulcrum-ftz-separation-homogenizer-2026 .feature-item span { color:#64748b; font-size:13px; line-height:1.55; }#fulcrum-ftz-separation-homogenizer-2026 .table-section,#fulcrum-ftz-separation-homogenizer-2026 .selection-section,#fulcrum-ftz-separation-homogenizer-2026 .series-choice,#fulcrum-ftz-separation-homogenizer-2026 .application-route { margin-top:18px; padding:20px; border:1px solid #dfe7ed; border-radius:8px; background:#fff; }#fulcrum-ftz-separation-homogenizer-2026 .section-heading p,#fulcrum-ftz-separation-homogenizer-2026 .selection-section>p,#fulcrum-ftz-separation-homogenizer-2026 .series-choice p,#fulcrum-ftz-separation-homogenizer-2026 .application-route p { color:#526170; }#fulcrum-ftz-separation-homogenizer-2026 .table-wrap { width:100%; margin-top:13px; overflow-x:auto; }#fulcrum-ftz-separation-homogenizer-2026 table { width:100%; border-collapse:collapse; }#fulcrum-ftz-separation-homogenizer-2026 th,#fulcrum-ftz-separation-homogenizer-2026 td { padding:9px 10px; border:1px solid #dfe7ed; text-align:left; vertical-align:top; }#fulcrum-ftz-separation-homogenizer-2026 th { background:#f1f6f9; color:#20384d; }#fulcrum-ftz-separation-homogenizer-2026 .table-note { margin-top:12px; color:#526170; }#fulcrum-ftz-separation-homogenizer-2026 .selection-grid { display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px; margin-top:14px; }#fulcrum-ftz-separation-homogenizer-2026 .selection-item { padding:13px 14px; border:1px solid #dfe7ed; border-radius:7px; background:#f8fbfd; }#fulcrum-ftz-separation-homogenizer-2026 .selection-item strong { display:block; margin-bottom:6px; color:#20384d; }#fulcrum-ftz-separation-homogenizer-2026 .selection-item p { color:#526170; }#fulcrum-ftz-separation-homogenizer-2026 .selection-note { margin-top:12px; padding:12px 14px; background:#f8fbfd; border-left:3px solid #24658f; color:#526170; }#fulcrum-ftz-separation-homogenizer-2026 .learn-more { margin-top:12px; color:#526170; }#fulcrum-ftz-separation-homogenizer-2026 .series-choice { display:flex; align-items:center; justify-content:space-between; gap:18px; }#fulcrum-ftz-separation-homogenizer-2026 .text-link { white-space:nowrap; }#fulcrum-ftz-separation-homogenizer-2026 .route-text { margin-top:10px; }@media(max-width:760px){ #fulcrum-ftz-separation-homogenizer-2026 .feature-row,#fulcrum-ftz-separation-homogenizer-2026 .selection-grid { grid-template-columns:1fr; } #fulcrum-ftz-separation-homogenizer-2026 .series-choice { display:block; } }
FT desktop ultrasonic homogenizer and cell disruptor
FT Desktop Ultrasonic Homogenizer
Fulcrum Technology | Collaborative developmentFT Desktop Ultrasonic HomogenizerFT Desktop Ultrasonic Homogenizer | 300–3,000 WThe FT desktop ultrasonic homogenizer / cell disruptor is designed for cell disruption, emulsification, particle dispersion, extraction, mixing, and material pretreatment. The series includes models from FT-300 to FT-3000. Choose a configuration according to sample volume, viscosity, processing goals, power, and probe size.300–3,000 WChoose power to match sample volume and applicationΦ3–Φ30 mmProbe sizes vary by modelVersatile sample preparationCell disruption, emulsification, dispersion, extraction, and mixingFT Desktop Ultrasonic Homogenizer SpecificationsModels mainly differ in power, standard probe size, and recommended processing volume. First narrow down the options by batch volume, then consider sample properties and processing goals.ModelFrequencyStandard probeProcessing volumeNet power outputOptional probe sizesTypical applicationsFT-30019–26 kHzΦ3 mm0.1–300 ml300 WΦ3–Φ8Small samples, initial testing, cell disruption, and small-volume dispersionFT-50019–26 kHzΦ6 mm0.1–500 ml500 WΦ3–Φ8Small to medium samples, emulsification, dispersion, cell disruption, and extractionFT-70019–26 kHzΦ8 mm0.1–800 ml700 WΦ3–Φ8Medium samples requiring higher energy for dispersion, emulsification, and mixingFT-100019–26 kHzΦ10 mm0.1–1,200 ml1,000 WΦ3–Φ10Medium-volume R&D, material dispersion, extraction, and sample pretreatmentFT-120019–26 kHzΦ13 mm0.1–1,500 ml1,200 WΦ3–Φ13Medium to large samples, higher-viscosity materials, or more intensive processingFT-150019–26 kHzΦ16 mm0.1–1,800 ml1,500 WΦ3–Φ16Larger volumes, material dispersion, emulsification, and scale-up evaluationFT-180019–26 kHzΦ18 mm0.1–2,200 ml1,800 WΦ3–Φ18Large-volume processing, high-energy dispersion, and material processing evaluationFT-200019–26 kHzΦ20 mm0.1–3,000 ml2,000 WΦ3–Φ20High-power, large-volume samples and more intensive dispersionFT-250019–26 kHzΦ25 mm0.1–3,000 ml2,500 WΦ3–Φ25High-power, large-volume processing, material dispersion, emulsification, and scale-up evaluationFT-300019–26 kHzΦ30 mm0.1–3,000 ml3,000 WΦ3–Φ30High-power, large-volume samples requiring higher-energy dispersionNote: Typical applications are selection references based on power, processing volume, and probe size. Actual results also depend on sample viscosity and solids content, vessel dimensions, probe position, processing time, temperature, and target outcome. Confirm final specifications and accessories before ordering.How to Choose an FT Desktop Ultrasonic HomogenizerDo not choose equipment based on the idea that more power is always better. Sample volume, probe size, and actual processing conditions are equally important in ultrasonic homogenization.Small sample volumesConsider the FT-300 or FT-500, and confirm probe size against your sample volume and vessel.Medium sample volumesConsider the FT-700, FT-1000, or FT-1200 for general R&D and sample pretreatment needs.Larger processing volumesDepending on sample conditions, consider the FT-1500, FT-1800, FT-2000, FT-2500, or FT-3000.For a quote or model recommendation, please provide: sample type, batch volume, viscosity or solids content, vessel dimensions, processing goal, whether temperature control is needed, and the desired outcome.If you are unsure how power, probe size, processing volume, and price relate, read How to Choose an Ultrasonic Homogenizer: Power, Probe, Volume, and Price.Not sure which model suits your sample?Emulsification, dispersion, cell disruption, and material processing require different conditions. Share your sample information so we can assess suitable FT models and probes based on your volume and application.Explore applications Ask for a recommendation#fulcrum-ft-desktop-homogenizer-2026{color:#334155;font-size:15px;line-height:1.72}#fulcrum-ft-desktop-homogenizer-2026 *{box-sizing:border-box}#fulcrum-ft-desktop-homogenizer-2026 p{margin:0}#fulcrum-ft-desktop-homogenizer-2026 a{color:#24658f;font-weight:800;text-decoration:none}#fulcrum-ft-desktop-homogenizer-2026 a:hover{color:#174565;text-decoration:underline}#fulcrum-ft-desktop-homogenizer-2026 h2,#fulcrum-ft-desktop-homogenizer-2026 h3{color:#20384d;font-weight:800}#fulcrum-ft-desktop-homogenizer-2026 h2{margin:0;font-size:26px;line-height:1.35}#fulcrum-ft-desktop-homogenizer-2026 h3{margin:0 0 10px;font-size:20px;line-height:1.4}#fulcrum-ft-desktop-homogenizer-2026 .product-intro{padding:22px;border:1px solid #dfe7ed;border-radius:8px;background:#f8fbfd}#fulcrum-ft-desktop-homogenizer-2026 .brand-line{display:flex;align-items:center;gap:12px;margin-bottom:13px;padding-bottom:12px;border-bottom:1px solid #dfe7ed}#fulcrum-ft-desktop-homogenizer-2026 .brand-logo{display:block;width:auto;max-width:115px;max-height:48px;height:auto;object-fit:contain}#fulcrum-ft-desktop-homogenizer-2026 .brand-line span{color:#64748b;font-size:13px;font-weight:700}#fulcrum-ft-desktop-homogenizer-2026 .eyebrow{margin-bottom:6px;color:#64748b;font-size:13px;font-weight:800}#fulcrum-ft-desktop-homogenizer-2026 .lead{max-width:920px;margin-top:12px;color:#526170;line-height:1.78}#fulcrum-ft-desktop-homogenizer-2026 .feature-row{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;margin-top:17px}#fulcrum-ft-desktop-homogenizer-2026 .feature-item{padding:13px 14px;border:1px solid #dfe7ed;border-radius:7px;background:#fff}#fulcrum-ft-desktop-homogenizer-2026 .feature-item strong,#fulcrum-ft-desktop-homogenizer-2026 .feature-item span{display:block}#fulcrum-ft-desktop-homogenizer-2026 .feature-item strong{margin-bottom:4px;color:#20384d;font-size:16px}#fulcrum-ft-desktop-homogenizer-2026 .feature-item span{color:#64748b;font-size:13px;line-height:1.55}#fulcrum-ft-desktop-homogenizer-2026 .table-section,#fulcrum-ft-desktop-homogenizer-2026 .selection-section,#fulcrum-ft-desktop-homogenizer-2026 .application-route{margin-top:18px;padding:20px;border:1px solid #dfe7ed;border-radius:8px;background:#fff}#fulcrum-ft-desktop-homogenizer-2026 .section-heading p,#fulcrum-ft-desktop-homogenizer-2026 .selection-section>p,#fulcrum-ft-desktop-homogenizer-2026 .application-route p{color:#526170;line-height:1.72}#fulcrum-ft-desktop-homogenizer-2026 .table-wrap{width:100%;margin-top:14px;overflow-x:auto;-webkit-overflow-scrolling:touch}#fulcrum-ft-desktop-homogenizer-2026 table{width:100%;min-width:850px;border-collapse:collapse;font-size:13px}#fulcrum-ft-desktop-homogenizer-2026 th,#fulcrum-ft-desktop-homogenizer-2026 td{padding:9px 10px;border:1px solid #dfe7ed;text-align:left;vertical-align:top}#fulcrum-ft-desktop-homogenizer-2026 th{background:#f1f6f9;color:#20384d;white-space:nowrap}#fulcrum-ft-desktop-homogenizer-2026 .table-note{margin-top:10px;color:#64748b;font-size:13px}#fulcrum-ft-desktop-homogenizer-2026 .selection-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;margin-top:14px}#fulcrum-ft-desktop-homogenizer-2026 .selection-item{padding:13px;border:1px solid #dfe7ed;border-radius:7px;background:#f8fbfd}#fulcrum-ft-desktop-homogenizer-2026 .selection-item strong{display:block;margin-bottom:5px;color:#20384d}#fulcrum-ft-desktop-homogenizer-2026 .selection-note{margin-top:14px;padding:12px;background:#f8fbfd;border-left:3px solid #24658f}#fulcrum-ft-desktop-homogenizer-2026 .learn-more{margin-top:12px!important}#fulcrum-ft-desktop-homogenizer-2026 .route-links{display:flex;gap:12px;margin-top:14px}@media(max-width:700px){#fulcrum-ft-desktop-homogenizer-2026 .feature-row,#fulcrum-ft-desktop-homogenizer-2026 .selection-grid{grid-template-columns:1fr}#fulcrum-ft-desktop-homogenizer-2026 .application-route{display:block}}
top