M60 / M90 Pilot-Scale High-Shear Dispersing Emulsifiers

The M60 / M90 pilot-scale high-shear dispersing emulsifiers handle emulsification, dispersion, homogenization, intensive mixing and solid–liquid dispersion at pilot scale and in larger batches. They can be used for formulation scale-up, process parameter validation, preproduction assessment and simulation between bench trials and production. The M60 handles 5–30 L and the M90 handles 10–50 L. Confirm the configuration based on batch volume, viscosity, solids content, target result, working head, stand and process conditions.

Pilot-Scale Applications

M60 / M90 Pilot-Scale High-Shear Dispersing Emulsifiers: Features and Applications

The M60 / M90 is designed for pilot-scale emulsification, dispersion, homogenization and mixing of medium to larger batches. It is suitable for formulation scale-up trials, process parameter validation and preproduction evaluation. Confirm batch volume, viscosity, solids content, vessel size, the desired emulsification or dispersion result and process conditions before specifying a configuration.

Pilot-scale sample processing

Use the M60 / M90 to scale up from bench trials and establish a test procedure that better represents actual process conditions.

Medium to larger batches

For emulsification, dispersion, homogenization and mixing, compare the M60 and M90 according to batch volume and processing objective.

High-shear design

The high-shear head supports rapid dispersion, emulsification and homogenization in pilot applications that require efficient mixing and a more consistent process.

Extended operation

The equipment can be evaluated for extended continuous operation and process simulation. Confirm operating conditions based on load, material properties and the working environment.

Formulation scale-up trials

Observe emulsification, dispersion and mixing as a formulation moves from small trial batches to larger volumes.

Process parameter validation

Evaluate how speed, shear time, addition sequence, temperature conditions and vessel configuration affect processing results.

From laboratory trials to production

The M60 / M90 provides a pilot-scale step between laboratory development and production, helping R&D and engineering teams define a process baseline. For viscous, high-solids, heat-sensitive or foaming samples, or extended operation, first provide the sample conditions and planned workflow to confirm the model and configuration.

Selection note: In addition to batch volume, consider viscosity, solids content, particle characteristics, vessel dimensions, whether an electric lift stand or extended continuous operation is needed, the target emulsification or dispersion result, and requirements for the next stage of the process.


Specifications

M60 / M90 Pilot-Scale High-Shear Dispersing Emulsifiers: Specifications

The M60 / M90 is suitable for pilot-scale and larger-batch emulsification, dispersion, homogenization, intensive mixing and solid–liquid dispersion. Use the specifications for preliminary comparison. Confirm the configuration against batch volume, viscosity, solids content, vessel dimensions, target result, working head and process conditions.

ModelM60M90
Motor power750W1500W
Power supply220V / 50Hz
380V optional
220V / 50Hz
380V optional
Batch volume5–30L10–50L
Viscosity5000 cP8000 cP
Speed range300–6000 rpm
Standard
300–6000 rpm
Standard
High-speed range60–12000 rpm
Optional
60–12000 rpm
Optional
Mixing throughput (H2O)1–15 L/min1–30 L/min
Speed controlVariable-frequency speed controlVariable-frequency speed control
DisplayDigital displayDigital display
Wetted materialSUS316LSUS316L
Shaft sleeve materialPTFEPTFE
Working head60BC90BC
Protection ratingIP54IP54
Variable-frequency driveStandardStandard
Overload protectionYesYes
Processing modeBatchBatch
StandElectric lift stand
Counterweight lift optional
Electric lift stand
Counterweight lift optional
Lift travel400 mm400 mm
Overall dimensionsElectric lift stand
500 × 400 × 915 mm
Electric lift stand
710 × 550 × 1060 mm
PackagingWooden crate
35 kg
Wooden crate
50 kg

Applications

The M60 / M90 high-shear dispersing emulsifiers support laboratory-to-pilot process simulation, helping evaluate the production workflow, process parameters and downstream equipment.

Hygienic configuration

Chemical-industry, food-hygiene or pharmaceutical-hygiene configurations can be evaluated according to the application. Confirm material, documentation and hygiene requirements against the product information and site requirements.

Processing uses

For pilot-scale or larger batches requiring efficient agitation, dispersion, homogenization, emulsification, intensive mixing or solid–liquid dispersion. Actual results depend on the material properties and process conditions.

Specification note: The M60 and M90 differ in motor power, batch volume, supported viscosity, mixing throughput, working head and dimensions. Consider the M60 for approximately 5–30 L. Consider the M90 for approximately 10–50 L or when more power and a larger working head are needed. Confirm viscosity, solids content, vessel dimensions, the target result, extended operating requirements and scale-up conditions.


Optional Accessories

Optional Accessories for the M60 / M90

Evaluate a lift stand or stainless steel vessel based on the pilot process, working height, vessel capacity and material characteristics. Confirm the configuration based on batch volume, viscosity, available space, workflow and site safety requirements.

M60 / M90 electric lift stand, manual lift stand and 50 L stainless steel process vessel

Electric lift stand

For applications requiring controlled lifting, frequent working-height adjustments or extended operation with a pilot-scale vessel.

Manual lift stand

A simpler height-adjustment option for laboratory and pilot-scale work with less frequent use or where budget and available space need to be considered.

50 L stainless steel process vessel

Evaluate the vessel against pilot batch volume, material and process needs. Check vessel dimensions, immersion depth, viscosity and cleaning requirements before choosing it.

Configuration note: Evaluate the accessories together with the model, working head, vessel size, liquid level, lift travel and available workspace. For process simulation or formulation scale-up trials, provide the planned batch size, material viscosity, vessel details and operating procedure to confirm the configuration.