Libraries and public spaces
Compare illuminance, CCT, and spectral conditions in libraries, classrooms, offices, reading areas, and shared spaces. Interpret results in light of measurement positions, site conditions, and applicable requirements.
Linshang|LS335
The LS335 uses a separate touchscreen controller and digital probe to measure illuminance, spectral curves, correlated color temperature (CCT), color rendering index (CRI), color tolerance, flicker, UV index, and plant-light PPFD. It is designed for luminaire R&D and quality control, public-space inspections, grow lights, and greenhouse lighting assessments.
The LS335 displays lux readings together with spectral distribution, CCT, color-rendering information, and other light-source parameters. It supports R&D and quality workflows that compare luminaires, production batches, measurement positions, and operating environments.
Compare illuminance, CCT, and spectral conditions in libraries, classrooms, offices, reading areas, and shared spaces. Interpret results in light of measurement positions, site conditions, and applicable requirements.
Review illuminance, spectrum, CCT, CRI, color tolerance, and flicker differences in desk lamps, LED luminaires, and indoor light sources.
Place the separate probe on the specified measurement plane for roadway lights, outdoor luminaires, and on-site inspections. Ambient light, probe direction, and measurement distance can affect results.
Compare PPFD, red-, green-, and blue-band PPFD, YPFD, and spectral curves in indoor farms, greenhouses, cultivation racks, and agricultural R&D.
The LS335 can display a spectral curve alongside current, maximum, minimum, and average illuminance, helping users observe changes in source output and establish more consistent measurement comparisons.
Spectral curves show relative energy distribution across wavelength bands. They can help compare different CCTs, LED formulations, full-spectrum luminaires, and production batches.
For meaningful comparisons, keep source output, warm-up time, measurement distance, probe position, and ambient conditions consistent.
View current, maximum, minimum, and average illuminance readings.
Review illuminance, spectrum, CCT, color rendering, and environmental parameters together.
Plant-light measurements help compare photosynthetically active light under different grow lights, mounting heights, cultivation areas, and spectral configurations.
Review PPFD, red-, green-, and blue-band PPFD, YPFD, and corresponding chlorophyll A and B parameters to compare lighting configurations for agricultural R&D or cultivation management.
PPFD is affected by luminaire output, mounting height, probe position, rack reflections, and ambient light. Use a consistent measurement grid rather than relying on a single point to represent an entire growing area.
In addition to illuminance and spectrum, the LS335 can display CCT, CRI, color tolerance, flicker, blue-light hazard ratio, and UV index. Whether a parameter is suitable for product acceptance or internal criteria depends on the product specification, measurement conditions, and inspection purpose.
Compare the warm or cool appearance and CCT of different luminaires for product development, batch quality control, and lighting evaluations.
Review color-rendering performance and consistency when comparing samples or luminaire batches.
Observe light-output fluctuations caused by LED luminaires and drivers for R&D, quality control, and preliminary field checks.
View blue-light proportion information as a light-source comparison reference. It is not a substitute for a complete photobiological safety assessment or risk determination.
View the ambient UV index. For UVA, UVB, or UVC irradiance, UV LEDs, or curing-energy measurements, evaluate a dedicated UV instrument for the required band.
Review ambient temperature and humidity to document measurement conditions.
View luminaire CCT values to compare the warm or cool appearance of different light sources.
Review Ra and color-tolerance information to compare color rendering and consistency across sources or luminaire batches.
Use the displayed UV index as an indication of ambient ultraviolet conditions. It is not equivalent to dedicated UVA, UVB, or UVC irradiance or energy measurement.
The LS335 separates the controller from its sensing probe. Place the probe at the required measurement position while the operator reviews readings on the controller; measurement data can also be organized on a computer.
The manufacturer's illustration shows spectral, UV, flicker, temperature, and humidity sensing together with digital signal processing in the probe.
The separate design helps position the probe on a specified test plane. Take probe orientation, obstructions, ambient light, and operator position into account during measurement.
The instrument can record measurement data for batch export, organization, and further analysis with the manufacturer's computer software. Confirm the software version, connection method, and functions supplied with the purchased configuration.
Consider the source level and measurement configuration when reviewing high-illuminance results or spectral response.
Manufacturer information lists an illuminance range up to 1,000,000 lux. Confirm suitability for the actual source, distance, and test conditions.
Illustration comparing the LS335 spectral-response curve with the V(λ) photopic response function.
Select a spectral illuminance meter according to the target source and inspection purpose. Prepare the following details before requesting a configuration recommendation.
Identify LED luminaires, desk lamps, roadway lights, stage lighting, grow lights, or other source types.
Confirm whether you need illuminance only, or also spectrum, CCT, CRI, flicker, PPFD, and other parameters.
Share the expected illuminance or PPFD, luminaire output, measurement distance, and planned probe position.
Confirm whether you need data storage, computer export, batch comparison, internal reports, or customer acceptance records.
Final configuration depends on sample conditions, inspection purpose, and the quality workflow. For calibration, test documents, or a specific standard, confirm the applicable service and document scope in advance.
Illuminance, luminance, and ultraviolet irradiance are different measurement needs. Select an instrument according to the source, measurement unit, and quality-control task.
The LS335 measures lux, CCT, color rendering, flicker, spectrum, and plant-light PPFD on a specified plane illuminated by a source.
Display, backlight, and emitting-surface luminance is generally expressed in cd/m². Consider the LS332 luminance meter.
For UV curing lamps, UV LEDs, sterilization lamps, or band-specific irradiance, evaluate a UV irradiance or UV energy meter for the wavelength and application.
Measurement bands, units, and operating methods differ by instrument. Review product information against the application requirements.
It can measure illuminance, spectral curves, CCT, CRI, color tolerance, flicker frequency and modulation depth, blue-light hazard ratio, UV index, temperature, and humidity. Plant-light mode also provides PPFD, red/green/blue-band PPFD, and YPFD information.
It can compare grow-light PPFD, spectral-band PPFD, YPFD, and spectral distribution. Keep luminaire height, output, probe position, and sampling method consistent when comparing lights or batches.
A basic lux meter mainly reports illuminance. The LS335 also displays spectrum, CCT, color rendering, flicker, and plant-light parameters for users who need additional light-source analysis.
The LS335 is intended to measure illuminance on a plane illuminated by a source. Display, backlight, and emitting-surface luminance is usually expressed in cd/m² and calls for a dedicated luminance meter.
No. The LS335 provides UV-index information. For UVA, UVB, or UVC irradiance, UV LEDs, or curing energy, select a dedicated UV instrument according to wavelength and use.
Keep warm-up time, output setting, measurement distance, probe direction, measurement plane, and ambient light consistent for more comparable batch results.
Related services or documents can be reviewed according to the calibration need. Confirm scope against the product version, measurement items, quality requirements, and intended use.
Demonstrations, inventory and lead-time checks, after-sales technical support, and repair services may be available depending on the product. Confirm the applicable model, condition, and service requirements.
Share the source type, measurement distance, expected illuminance or PPFD range, required optical parameters, and current quality workflow. Fulcrum Technology can help review the product direction and application. For a demonstration, stock, delivery, or repair inquiry, include the model and service needs.
The specifications below summarize the published LS335 configuration. Actual range and accuracy depend on the probe, revision, and measurement conditions; confirm the current datasheet before ordering.
| Item | Specification | Notes |
|---|---|---|
| Model | LS335 | Touchscreen spectral illuminance meter |
| Wavelength range | 400–700 nm | 10 nm interval |
| Illuminance range | 0–1,000,000 Lux | 0.1 Lux resolution |
| Illuminance accuracy | ≤ ±(3%H+2 Lux) | H is the reference value; calibrated with CIE standard illuminant A |
| Illuminance units | Lux (default), FC | Selectable display units |
| CCT range | 1,000–100,000 K | Correlated color temperature |
| CCT accuracy | ±5% | Calibrated with CIE A |
| CRI range | 0–100 | Color rendering index |
| CRI accuracy | ±2 | Calibrated with CIE A |
| UV index | 0.0–15.0 | Ambient UV index value |
| UV accuracy | ±10% | Refer to probe configuration and test conditions |
| Flicker frequency | 10–500 Hz | Light-source flicker measurement |
| Frequency accuracy | ±5% | Under specified measurement conditions |
| Ambient temperature | −40–120 ℃ | ±0.5 ℃ accuracy |
| Ambient humidity | 0–100% RH | ±4% RH accuracy |
| PPFD range | 0–10,000 μmol/m²/s | Accuracy ≤ ±(5%H+0.5 μmol/m²/s) |
| Blue-band PPFD | 0–5,000 μmol/m²/s | Accuracy ≤ ±(10%H+0.5 μmol/m²/s) |
| Green-band PPFD | 0–5,000 μmol/m²/s | Accuracy ≤ ±(10%H+0.5 μmol/m²/s) |
| Red-band PPFD | 0–5,000 μmol/m²/s | Accuracy ≤ ±(10%H+0.5 μmol/m²/s) |
| YPFD | 0–10,000 μmol/m²/s | Accuracy ≤ ±(5%H+0.5 μmol/m²/s) |
| Chlorophyll A | 0–10,000 μW/cm² | Accuracy ≤ ±(10%H+0.5 μW/cm²) |
| Chlorophyll B | 0–10,000 μW/cm² | Accuracy ≤ ±(10%H+0.5 μW/cm²) |
| Response time | <0.7 s | — |
| Sensor aperture | Φ21 mm | — |
| Controller dimensions | 141 × 70.4 × 22 mm | — |
| Probe dimensions | 40 mm diameter × 20 mm thick | — |
| Weight | Approx. 277 g | — |
| Display | 480 × 320 color IPS | Touchscreen |
| Battery | 3.7 V / 4,000 mAh rechargeable lithium battery | — |
| Data storage | 1,000 records | — |
| Operating conditions | 0–40 ℃ | Operating humidity <85% RH |
| Power supply | DC 5 V | — |
| Current | 133 mA | — |
| Power | 665 mW | Published configuration specification |
Values follow the manufacturer's current public version. Confirm probe range, calibration, test conditions, and delivered configuration with Fulcrum Technology before ordering.
These videos introduce the LS335 Spectral Illuminance Meter's physical controls, measurement interface, and feature applications. Confirm the actual screen, software functions, and operating procedure against the specific product model and official documentation.
This video introduces the LS335's main measurement functions and operating interface as an initial reference for illuminance, spectral, and related light-source measurements.
This video shows the LS335's operation and measurement scenarios to help you understand the instrument interface, probe use, and on-site applications.