TS7700 Spectrophotometer (Dual Aperture)

The TS7700 is a handheld dual-aperture spectrophotometer with D/8 geometry, a plane diffraction grating, a dual-row silicon photodiode array with 40 groups, and a full-spectrum LED source. It supports SCI/SCE, UV-included / UV-excluded measurements, Lab color data, ΔE evaluation, and spectral reflectance analysis. Its apertures are MAV: Φ8 mm / Φ10 mm and SAV: Φ4 mm / Φ5 mm. It can be evaluated for color quality control in plastics and electronics, paints and coatings, textiles and dyeing, printing, automotive, medical, cosmetics, food, and laboratories. Confirm sample size, surface, measurement area, fluorescence conditions, and QC workflow before selecting.

Product Overview

TS7700 Spectrophotometer | Dual Apertures, UV and Advanced Color QC

TS7700 spectrophotometer uses D/8 optical geometry and supports SCI/SCE measurement modes, UV-included / UV-excluded measurement, a full-spectrum combined LED source, a dual optical path, and a silicon photodiode array. It is designed for applications requiring spectral reflectance, color data, and QC traceability.

The TS7700 supports Φ8 mm / Φ4 mm aperture switching and platform / pointed measurement configurations. Evaluate the setup based on sample size, surface condition, and measurement location. Applications may include plastics and electronics, paints and coatings, textiles and dyeing, printing, automotive, medical, cosmetics, food, and laboratories for Lab color data and ΔE evaluation, incoming inspection, R&D comparison, and process QC. Final selection should reflect the sample, inspection purpose, aperture, and QC workflow.

Key Features

TS7700 Spectrophotometer Features

Designed for dual-aperture measurement, SCI/SCE comparison, UV condition evaluation, data storage, and color QC management.

01

D/8 optical geometry

Uses D/8 geometry and aligns with relevant measurement conditions such as CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164, and DIN 5033 Teil 7. It can be considered for color QC and R&D comparison workflows.

02

Full-spectrum LED source and UV conditions

The long-life, low-power combined full-spectrum LED source supports UV-included / UV-excluded measurement to evaluate color differences in fluorescent or optical-brightener-containing samples when required.

03

Φ8 / Φ4 mm dual-aperture switching

Switch between Φ8 mm and Φ4 mm apertures and pair platform or pointed measurement ports with the sample shape and measurement location for samples of different sizes and surface conditions.

04

Dual optical path and SCI/SCE spectra

The dual optical path supports spectral measurement in the visible range and simultaneous SCI and SCE sample spectra, helping compare how gloss, texture, or specular reflection affects color assessment.

05

Spectral and Lab color data

Measure sample spectra and Lab color data to support formulation, batch comparison, supply-chain acceptance, and color communication. Acceptance decisions should follow internal standards and QC procedures.

06

3.5-inch touchscreen and advanced hardware

Features a 3.5-inch TFT color display, capacitive touchscreen, 1000-line blazed grating, and a silicon photodiode array with a large photosensitive area for operation and data review.

07

USB / Bluetooth communication

USB and Bluetooth support data transfer and management for field inspection, laboratory workflows, and QC reports. Confirm actual features for the supplied hardware and software versions.

08

Standard white tile

The standard white tile can be used in routine calibration and measurement workflows to help maintain consistent test conditions. Follow the manufacturer’s procedures for storage and calibration.

09

Large data storage

Stores more than 30,000 test records for batch tracking, incoming inspection records, and long-term QC data management.

10

Multiple illuminants, color spaces, and indices

Supports 2° / 10° standard observer angles, multiple illuminant modes and color spaces, and colorimetric indices aligned with multiple standards. Configure them for the industry’s color assessment workflow.

11

Camera viewfinder and positioning plate

Camera viewfinder positioning and positioning-plate measurement help operators confirm the measurement location and reduce variation caused by misalignment.

12

PC software expansion

Optional PC software can support color data management, color-difference comparison, and reporting. Confirm functions, export formats, and data-management options for the supplied version.

Selection Guide

How does the TS7700 compare with other high-end spectrophotometers?

Start by comparing aperture configuration, UV conditions, fluorescent samples, data management, and measurement scenarios.

TS7700 | Dual apertures and UV evaluation

For Φ8 mm / Φ4 mm switching, SCI/SCE, UV-included / UV-excluded conditions, and color data management, consider the TS7700 spectrophotometer .

FTZ series | Handheld multi-aperture field measurement

For handheld multi-aperture measurements, field inspections, or multiple measurement points, compare FTZ7 , FTZ8 and FTZ9 .

FTS7000 | Five-aperture high-end measurement

For five apertures, a wider range of sample sizes, and advanced color management, compare the FTS7000 spectrophotometer .

Aurora | Nine apertures and special samples

For small, curved, or special-location samples requiring nine apertures and evaluation across multiple sample conditions, see the Aurora array spectrophotometer .

FAQ

TS7700 Frequently Asked Questions

Questions to resolve before introducing dual-aperture measurement, UV conditions, SCI/SCE, and color QC.

What samples and industries is the TS7700 suitable for?

It can be evaluated for color QC in plastics and electronics, paints and coatings, textiles and dyeing, printing, automotive, medical, cosmetics, food, and laboratories. Confirm suitability based on the sample material, surface, measurement area, and QC workflow.

How should I choose between Φ8 mm and Φ4 mm?

Φ8 mm can suit general samples or a more stable measurement area; Φ4 mm can suit small areas or local points. For curved, textured, glossy, or undersized samples, provide sample details to confirm the aperture.

When are the TS7700 UV conditions useful?

UV-included / UV-excluded measurement can help evaluate color differences in fluorescent or optical-brightener-containing samples under different UV conditions. Confirm customer acceptance conditions and measurement standards for fluorescent materials, textiles, paper, or special coatings.

What is SCI/SCE measurement used for?

SCI/SCE measurement helps compare whether surface specular reflection is included in color data. For glossy, matte, coated, textured, or gloss-variable samples, confirm whether SCI, SCE, or both must be recorded under the acceptance specification.

How is the TS7700 different from a general color-difference meter?

A general color-difference meter is often used for quick comparisons. The TS7700 is a spectrophotometer that can provide spectral reflectance, Lab data, ΔE evaluation, and multiple colorimetric indices for R&D comparison, supply-chain acceptance, and QC traceability.

What information should I provide before adopting a TS7700?

Provide sample material and dimensions, spot size, surface gloss, texture or curvature, fluorescence or optical brighteners, color-difference formula, observer illuminant, acceptance limits, SCI/SCE or UV requirements, and data storage and report needs.

Pre-deployment checks

For fluorescent or brightened samples, small areas, curved or textured surfaces, gloss differences, or multiple suppliers, share the sample conditions, inspection purpose, and internal criteria before confirming the aperture, UV conditions, SCI/SCE settings, and data-management workflow.

Contact Fulcrum Technology for selection advice

Specification

TS7700 Spectrophotometer Specifications

These specifications are a reference for TS7700 selection, purchasing, and QC deployment. The instrument has MAV: Φ8 mm / Φ10 mm and SAV: Φ4 mm / Φ5 mm apertures, with SCI/SCE and UV-included / UV-excluded measurement. Confirm sample size, surface condition, measurement area, fluorescence conditions, and QC workflow before selection.

Product modelTS7700 spectrophotometer
Measurement geometryD/8 (diffuse illumination, 8° viewing); SCI/SCE measurement; UV-included / UV-excluded measurement
DetectorSilicon photodiodes (dual row, 40 groups)
Spectral methodPlane diffraction grating
Integrating sphere sizeΦ40 mm
Illumination sourceCombined full-spectrum LED source and UV source
Wavelength range400–700 nm
IlluminantsD65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30)
Wavelength interval10 nm
Reflectance range0–200%
Measurement aperturesDual apertures: MAV: Φ8 mm / Φ10 mm; SAV: Φ4 mm / Φ5 mm
Specular componentSCI / SCE measured simultaneously
Color spacesCIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy, DIN Lab99, Munsell (C/2)
Color-difference formulasΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE (Hunter)
Other colorimetric indicesWI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM E313), metamerism index Mt, staining fastness, color-change fastness, color strength, opacity, 8° gloss, 555 hue classification
Observer angle2° / 10°
Display parametersSpectral graph / data, sample colorimetric values, color differences / graph, pass / fail result, color simulation, color cast
Measurement timeApprox. 1.5 s
RepeatabilitySpectral reflectance: MAV / SCI, standard deviation ≤0.08% (≤0.18% from 400–700 nm); colorimetric value: MAV / SCI, ΔE*ab ≤0.03 (average of 30 white-tile measurements at 5-second intervals after warm-up and calibration)
Inter-instrument differenceMAV / SCI, ΔE*ab ≤0.15 (average across 12 BCRA Series II color tiles)
Measurement modesSingle measurement, average measurement (2–99 readings)
PositioningCCD viewfinder positioning, positioning plate
Dimensions129 × 76 × 217 mm (H × W × D)
Weight600 g
BatteryLithium battery, 3.7 V, 5000 mAh; up to 6,000 measurements within 8 hours
Light-source lifeApprox. 5 years or more than 1.5 million measurements
Display3.5-inch TFT color display, capacitive touchscreen
ConnectivityUSB, Bluetooth 4.2
Data storage1,000 standards and 30,000 samples (one record can include both SCI / SCE)
Software supportWindows、Android、iOS
LanguagesTraditional Chinese, Simplified Chinese, English
Operating temperature0–40°C, 0–85% relative humidity (non-condensing)
Storage temperature-20–50°C (non-condensing)
Standard accessoriesPower adapter, data cable, user manual, quality management software (official website download), black-and-white calibration box, protective cover, wrist strap, Ø8 mm platform aperture, Ø8 mm pointed aperture, Ø4 mm platform aperture, Ø4 mm pointed aperture
Optional accessoriesMini printer, powder test box

Specification note: The TS7700 is a dual-aperture spectrophotometer for general and small-area samples, UV evaluation, and color QC traceability. For fluorescent or brightened samples, curved or textured surfaces, gloss differences, or samples from multiple suppliers, provide sample details to confirm the aperture, SCI/SCE and UV conditions, and data-management workflow. These specifications reflect the current product information; confirm the supplied version with the manufacturer or Fulcrum Technology.

top