NS808 Traffic Sign Spectrophotometer

The NS808 is designed for color measurement of road traffic reflective sheeting, safety colors, traffic signs, road markings and other reflective materials. With the traffic sign measurement module in SQCT software, it helps assess whether sample chromaticity coordinates and luminance factor fall within specified color regions under D65/A illuminants and 45°/0° geometry. Confirm suitability against the applicable standard, sample material, reflective material type, measurement conditions, and your quality-control procedures.

Product Overview

NS808 Traffic Sign Spectrophotometer | Color Assessment for Reflective Sheeting and Safety Colors

The NS808 Traffic Sign Spectrophotometer is designed for chromaticity testing of road-traffic reflective sheeting, safety colors, traffic signs, road markings and related reflective materials. Unlike routine color workflows focused mainly on Lab color values and ΔE color difference, traffic-sign and safety-color applications often require checking whether chromaticity coordinates and luminance factor fall within a specified color region.

Using 45°/0° geometry, the NS808 works with the traffic-sign measurement module in SQCT software to assess chromaticity coordinates, polygonal color regions, luminance factor and pass/fail results. Confirm the applicable standard, sample material, reflective-material type, measurement conditions and internal QC workflow before implementation.

Diagram of chromaticity coordinates and polygon color-region assessment for the NS808
Key Features

NS808 Traffic-Sign Measurement Applications

Designed for color-region assessment of traffic signs, reflective sheeting, safety colors and road-marking materials.

01

45°/0° Measurement Geometry

Uniform circumferential illumination at 45° with 0° reception provides a measurement geometry for evaluating traffic signs, reflective sheeting and safety colors.

02

D65, A, C and F2 Illuminants

Multiple illuminant conditions can be selected to suit the applicable standard or inspection requirement for luminance factor, chromaticity coordinates and CIE L*a*b* data.

03

Chromaticity-Region Assessment

Traffic-sign and safety-color standards often define color regions using multiple chromaticity points. With SQCT software, the NS808 can help determine whether a sample falls within a specified polygonal region.

04

Luminance-Factor Testing

In addition to chromaticity coordinates, traffic signs and reflective materials may require luminance-factor checks. Confirm the applicable standard, sample type and test procedure for each application.

05

Traffic-Sign Module in SQCT

The SQCT traffic-sign module supports standard color regions, reference-sample setup, color-region assessment and test-result management for QC and inspection teams.

06

Custom Polygon Tolerance Samples

When a standard or customer specification defines a custom chromaticity range, enter the vertex coordinates in sequence to create a polygon tolerance sample. Enter vertices clockwise or counter-clockwise to avoid an incorrect assessment region.

Workflow

SQCT Traffic-Sign Measurement Workflow

These are common steps for using the NS808 with SQCT to assess traffic-sign colors. Follow the instructions for your software version and supplied documentation.

SQCT standard measurement interface for color data and color-difference formulas

Standard Color Measurement

After connecting the NS808 to SQCT, begin with the standard measurement interface for CIE L*a*b*, XYZ, ΔE*ab, ΔE*cmc and ΔE*00 data.

SQCT traffic-sign module for assessing reflective materials and safety colors

Open Traffic-Sign Measurement

Use the SQCT settings menu to open the traffic-sign module for reflective road materials, safety colors or custom standards.

NS808 traffic-sign reference-sample menu with reflective-material and safety-color standards

Select or Create a Standard

Choose a road-traffic reflective-material standard, a safety-color standard or a custom standard. Polygon tolerance samples can be added, edited or removed as needed.

SQCT setup for polygon tolerance samples with chromaticity and luminance-factor conditions

Build a Polygon Tolerance Sample

Enter the standard's chromaticity vertices, then set the illuminant, observer angle and luminance factor to define the sample region for assessment.

Example result showing whether sample chromaticity falls within the traffic-sign color region

Assess the Color Region

After measurement, compare the sample's chromaticity coordinates with the standard region and review luminance-factor conditions for an initial pass/fail assessment.

SQCT custom traffic-sign standard setup for a user-defined chromaticity range

Apply a Custom Standard

Create a dedicated polygon tolerance sample for an organization or customer-defined color range to support internal QC or pre-acceptance review.

FAQ

Frequently Asked Questions about the NS808

Key points to confirm when assessing the NS808 for traffic signs, reflective sheeting, safety colors, chromaticity and luminance-factor requirements.

What samples and industries is the NS808 suited for?

It is intended for road-traffic reflective sheeting, traffic signs, safety colors, road markings, reflective materials and related color-inspection work. For routine color-difference QC of plastics, coatings or general product appearance, confirm whether the NS808 or a general-purpose spectrophotometer is more appropriate.

How does the NS808 differ from a general spectrophotometer?

General spectrophotometers often focus on Lab values and ΔE color difference. The NS808 is oriented toward chromaticity coordinates, luminance factor and color-region assessment for traffic signs, safety colors and reflective materials. It may be suitable when a specification requires checking whether a sample falls within a defined color region.

What is chromaticity-region assessment?

Traffic-sign and safety-color standards may define a polygonal region using multiple chromaticity points. After measuring a sample, the NS808 with SQCT can help assess whether its coordinates fall inside that region. Confirm final acceptance criteria against the applicable standard.

Can the NS808 assess luminance factor?

The NS808 can be used to assess luminance factor for traffic-sign and safety-color applications. Confirm the illuminant, observer angle, material type, applicable standard and test procedure; provide these details before implementation.

Can SQCT use a custom traffic-sign standard?

A custom polygon tolerance sample can be created by entering chromaticity coordinates for its vertices and setting the related conditions. Enter vertices clockwise or counter-clockwise to avoid an incorrect region. Available functions depend on the supplied software version.

What should I provide before selecting the NS808?

Share the applicable standard, sample material and reflective-material type, required illuminant and observer angle, chromaticity range, luminance-factor criteria, sample surface, report needs and internal QC or acceptance workflow. This helps determine whether the NS808 fits the inspection requirement.

Checks Before Implementation

The NS808 is intended for traffic-sign, reflective-material and safety-color assessment. Confirm the applicable standard, illuminant, observer angle, 45°/0° geometry, luminance-factor criteria, chromaticity range, sample surface and reporting needs. If routine color-difference control for general materials is also required, consider whether a D/8 or SCI/SCE spectrophotometer should be used alongside it.

Contact Fulcrum Technology about NS808 testing

NS808 Traffic Sign Spectrophotometer Specifications

Use these specifications as a reference when evaluating the NS808 for traffic-sign, reflective-material and safety-color inspection. The 45°/0° geometry, 58 mm integrating sphere, 8 mm aperture and 400–700 nm range describe the listed configuration. Confirm the applicable standard, sample type and supplied configuration before purchase or quality-control implementation.

Product model

NS808 Traffic Sign Spectrophotometer

Measurement geometry

45°/0° (uniform 45° ring illumination, 0° reception); complies with CIE No.15, GB/T 3978, GB 2893 and GB/T 18833

Detector

Silicon photodiode array

Spectral method

Planar grating

Integrating sphere diameter

Φ58 mm

Illumination source

Combined full-spectrum LED

Wavelength range

400–700 nm

Illuminants

D65, A, C, D50, D55, D75, F2, F6, F7, F8, F10, F11, F12

Resolution

0.01

Wavelength interval

10 nm

Reflectance measurement range

0–200%

Measurement aperture

Φ8 mm

Measurement mode

SCI (specular component included)

Color spaces

CIE LAB, XYZ, Yxy, LCh, CIE LUV

Color difference formulas

ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00

Other color indices

WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), metamerism index Mt, staining fastness, color fastness, color strength, hiding power

Observer angle

2°/10°

Displayed parameters

Reflectance at 3 user-selected wavelengths; sample color values; color difference/value graph; pass/fail result; color simulation; color bias

Measurement time

Approx. 1.5 seconds

Repeatability

Spectral reflectance: standard deviation ≤0.1% (≤0.2% over 400–700 nm); color value ΔE*ab ≤0.04 (after calibration, average of 30 white-tile readings at 5-second intervals)

Inter-instrument difference

ΔE*ab ≤0.2 (average measured across 12 BCRA Series II color tiles)

Measurement method

/

Positioning method

Positioning plate

Dimensions

L × W × H = 90 × 77 × 230 mm

Weight

600 g

Battery

Rechargeable lithium battery

Lamp life

Approx. 5 years; more than 1.5 million measurements

Display

3.5-inch full-color TFT capacitive touchscreen

Connection

USB, TTL

Data storage

1,000 standards; 10,000 samples

Software support

Windows

Languages

Traditional Chinese, Simplified Chinese, English

Operating conditions

0–40℃; 0–85% relative humidity (non-condensing)

Storage temperature

-20–50℃ (non-condensing)

Standard accessories

Power adapter, data cable, user manual, black/white calibration box, protective cap, wrist strap, lithium battery

Optional accessories

Multifunction test fixture for liquids, powders and granules; mini printer, powder test box, instrument stand

Selection note: Specifications are provided as a reference. Confirm the actual supplied configuration, inspection standard, sample surface and measurement conditions with Fulcrum Technology before final selection.