Spectrophotometer TS20

TS20 SpectrophotometerThe TS20 spectrophotometer supports Lab color data, ΔE color difference evaluation, SCI measurement, incoming inspection, in-process checks, and batch color comparison. It is suited to applications that need a routine color quality control workflow, storage of standard and test sample data, and quick on-site assessment.Actual selection should be based on sample size and surface condition, measurement area, gloss differences, measurement aperture, and your internal quality control process.

Product Overview

TS20 Spectrophotometer | 8 mm Aperture, Lab Color Data and Routine Color-Difference Control

The TS20 is designed for quality-control, R&D and process teams building a routine color-inspection workflow. It supports Lab color data and ΔE evaluation for incoming inspection, in-process checks, batch comparison and basic quality records.

With a Φ8 mm aperture, 10° observer angle, combined full-spectrum LED source and plane-grating dispersion, the TS20 suits routine color control for plastics, coatings, inks, textiles, printing, packaging and general manufacturing. For quick on-site comparisons and simpler daily checks, also compare the TS10 spectrophotometer. Final selection should consider sample size and surface, measurement area, gloss, data-retention needs and your internal QC workflow. See our explanation of Lab values and ΔE color difference.

Key Features

TS20 Spectrophotometer Features

Built around an 8 mm aperture, Lab data, color-difference assessment, on-site checks and everyday QC data management.

01

Φ8 mm Measurement Aperture

The Φ8 mm aperture and 10° observer angle provide a practical option for many general-size samples, flat materials and routine color comparisons.
02

Full-Spectrum LED and Grating Dispersion

A combined full-spectrum LED source and plane grating work with the full-color capacitive touchscreen for on-site operation, color-difference checks and QC review.
03

Dual-Row, 24-Group Sensor

The dual-row silicon photodiode array contains 24 groups for routine color-difference inspection, batch comparison, reflectance readings and color-data records.
04

Long-Life Source and Rechargeable Battery

Published information lists a light-source life of about five years and more than 3 million measurements. The rechargeable lithium battery supports field checks; actual service depends on use and operating conditions.
05

Reference and Sample Data Storage

Store reference standards and samples for batch comparison, lookup, routine analysis and supplier incoming-inspection records.

Selection Guide

How to Choose Between TS20 and TS10

Both are portable spectrophotometers. Choose based on data retention, inspection frequency, QC records and the way the instrument will be used—not SCI alone.

TS20 | Routine QC and Data Records

Consider the TS20 spectrophotometer when incoming inspection, process checks, batch comparisons, reference/sample storage and basic QC records are part of the workflow. Confirm suitability against your samples, acceptance criteria and data-management process.

TS10 | Quick On-Site Comparisons

Compare the TS10 spectrophotometer when the priority is quick field comparisons, general-size samples, basic Lab data and ΔE checks. If you later need broader data management or long-term batch tracking, reassess the model against your QC workflow.

FAQ

TS20 Spectrophotometer: Frequently Asked Questions

Answers about the 8 mm aperture, routine color-difference inspection, Lab data, data storage and comparison with the TS10.

What routine QC tasks is the TS20 suited for?

It can support incoming inspection, process checks, on-site sampling, supplier batch comparison and general color-difference assessment. Teams that need reference/sample storage and basic inspection records may evaluate it as a starting point.

What samples suit the 8 mm aperture?

The Φ8 mm aperture is intended for general-size samples, flat materials or products with enough measurement area, such as molded plastics, coated surfaces, paper, packaging, textile swatches and common manufactured parts. For small, curved or constrained measurement points, share sample details to confirm whether another aperture is more suitable.

How should I choose between TS20 and TS10?

The TS20 may be considered where reference/sample storage, routine batch records and basic QC data management are needed. The TS10 is another option for quick on-site comparisons and basic daily checks. Verify the actual differences against the product specifications, data-retention method, inspection frequency and supplied version.

Can the TS20 be used for supplier incoming inspection?

It can support supplier-batch color comparisons and basic color records. If acceptance requires extensive traceability, report exports, multi-department integration or more advanced QC software, describe the workflow to determine whether a higher-tier model is needed.

What information should I provide before selecting the TS20?

Provide the sample material and dimensions, spot size, surface gloss, texture or curvature, color-difference formula, acceptance limits, inspection frequency and whether reference/sample records must be retained. This helps confirm fit with your QC process.

Can the TS20 replace visual color assessment?

Lab data and ΔE results can reduce the subjectivity of visual-only judgments. Final QC criteria should still reflect product appearance requirements, customer acceptance conditions, lighting and your internal standards.

Before implementation: If samples are small, curved, textured or glossy, or involve multiple batches or suppliers, share the sample conditions, inspection goal and internal criteria. Then confirm that the TS20 Φ8 mm aperture, measurement conditions, data-retention needs and workflow suit the application.

Contact Fulcrum Technology for TS20 selection advice


TS20 SPECTROPHOTOMETER

TS20 Spectrophotometer Specifications

Use these specifications as a reference when evaluating, purchasing or introducing the TS20 into a quality-control workflow. The TS20 uses D/8 geometry with a Φ8 mm platform aperture and supports SCI measurement, Lab color data and ΔE assessment for routine color control. Confirm the final configuration against the sample, surface, measurement area, gloss and internal QC requirements.

SpecificationTS20
Product modelTS20 professional spectrophotometer
Measurement geometryD/8 (diffuse illumination, 8° directional viewing); SCI measurement. Standards: CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164 and DIN 5033 Part 7.
DetectorSilicon photodiode array, dual row with 24 groups
Spectral dispersionPlane grating
Integrating sphere diameterΦ40 mm
Illumination sourceCombined full-spectrum LED source
Wavelength range400–700 nm
IlluminantsD65, A and F2 (CWF)
Resolution0.01
Wavelength intervalNot specified in the available product information
Reflectance measurementMeasures reflectance at three user-selected wavelengths; default wavelengths are 440 nm, 550 nm and 600 nm.
Measurement apertureΦ8 mm
Measurement modeSCI (specular component included)
Color spacesCIE LAB, XYZ, Yxy and LCh
Color-difference formulasΔE*ab and ΔE*00
Other colorimetric indicesNot specified in the available product information
Observer angle10°
Displayed parametersReflectance at three user-selected wavelengths, sample color values, color difference values and graphs, pass/fail results, color simulation and color bias
Measurement timeApprox. 1.5 seconds
RepeatabilityColorimetric value, MAV/SCI: ΔE*ab ≤ 0.08 after warm-up and calibration; average of 30 white-tile measurements taken at 5-second intervals
Instrument-to-instrument variationMAV/SCI: ΔE*ab ≤ 0.4; average across 12 BCRA Series II color tiles
Measurement methodSingle measurement or average measurement (2–99 readings)
PositioningStable plate positioning
Dimensions (L × W × H)81 × 71 × 214 mm
Weight460 g
BatteryRechargeable lithium battery
Light-source lifeApprox. 5 years; more than 1.5 million measurements
Display3.5-inch TFT full-color capacitive touchscreen
ConnectionType-C USB (charging only); Bluetooth 5.0
Data storage500 reference standards and 10,000 samples
Software supportNot specified in the available product information
LanguagesTraditional Chinese, Simplified Chinese and English
Operating environment0–40 °C; 0–85% relative humidity, non-condensing
Storage environment−20–50 °C, non-condensing
Standard accessoriesPower adapter, data cable, user manual, black-and-white calibration box, protective cover, wrist strap and single Φ8 mm platform aperture
Optional accessoriesMini printer and powder test box

Selection note: The TS20 is a single-aperture handheld spectrophotometer for Φ8 mm platform measurements, SCI readings, routine color-difference assessment and batch data management. If samples are small, curved, textured or glossy—or if SCI/SCE switching, color-chart search, app functions or CCD viewing-position assistance are required—consider other models and verify suitability with actual samples.

top