High and Low Temperature Test Chamber DCL-36 / DCL-80 / DCL-120

The DCL-36, DCL-80, and DCL-120 high and low temperature test chambers simulate high, low, and changing temperature conditions for material and electronic component testing, product stability observation, R&D verification, and quality control. When selecting a model, confirm the test temperature range, chamber capacity, sample dimensions, temperature ramp conditions, and test workflow. Verify actual specifications with the manufacturer or Fulcrum Technology.

High and Low Temperature Test Chamber DCL-36 / DCL-80 / DCL-120

The DCL-36, DCL-80, and DCL-120 chambers simulate high, low, and changing temperature conditions for material and electronic component testing, product stability observation, R&D verification, and quality control. When selecting a model, first confirm the test temperature range, chamber capacity, sample dimensions, temperature ramp conditions, test duration, and whether programmable temperature control is required.

Fulcrum Technology can help assess a suitable high and low temperature test chamber for laboratories, R&D teams, and quality control based on product information and application needs. Confirm actual specifications, stock, lead time, and repair service details for the model and requirements.

High and Low Temperature Simulation

Supports testing under high, low, and changing temperature conditions to observe the stability and behavior of materials, components, or products in different temperature environments.

Programmable Temperature Control

Equipped with an imported computer-based programmable temperature controller. Test profiles can be set from 1 program with 15 steps up to 2 programs with 30 steps; confirm the actual configuration and controller version against the supplied unit.

DCL-36 / DCL-80 / DCL-120 Model Options

The DCL series includes three models: DCL-36, DCL-80, and DCL-120. Select a suitable model based on sample dimensions, test capacity, chamber space, and workflow.

Air Circulation and Safety Design

A multi-blade high-flow fan and long stainless-steel shaft circulate air. Safety features include power over-temperature protection and overload protection switches for the refrigeration unit and motor.

Key Specifications

ItemDCL-36DCL-80DCL-120
ModelDCL-36DCL-80DCL-120
Temperature Range-40°C~+120°C-40°C~+120°C-40°C~+120°C
Temperature Accuracy0.2°C; temperature uniformity: 1–1.5°C at 100°C0.2°C; temperature uniformity: 1–1.5°C at 100°C0.2°C; temperature uniformity: 1–1.5°C at 100°C
Temperature ControllerImported computer-based programmable temperature controller, 1 program with 15 steps to 2 programs with 30 stepsImported computer-based programmable temperature controller, 1 program with 15 steps to 2 programs with 30 stepsImported computer-based programmable temperature controller, 1 program with 15 steps to 2 programs with 30 steps
Control SystemSSR controlSSR controlSSR control
Chamber MaterialStainless steel interior; galvanized steel exterior with powder coatingStainless steel interior; galvanized steel exterior with powder coatingStainless steel interior; galvanized steel exterior with powder coating
Circulation SystemMulti-blade high-flow fan and long stainless-steel shaft for air circulation and even temperature distributionMulti-blade high-flow fan and long stainless-steel shaft for air circulation and even temperature distributionMulti-blade high-flow fan and long stainless-steel shaft for air circulation and even temperature distribution
Refrigeration UnitImported low-noise compressorImported low-noise compressorImported low-noise compressor
Internal Dimensions W × D × H40 × 30 × 30 cm40 × 40 × 50 cm50 × 40 × 60 cm
External Dimensions W × D × H64 × 83 × 130 cm64 × 93 × 155 cm74 × 93 × 165 cm
Safety FeaturesPower over-temperature protection; overload protection switches for refrigeration unit and motorPower over-temperature protection; overload protection switches for refrigeration unit and motorPower over-temperature protection; overload protection switches for refrigeration unit and motor
AccessoriesIncludes 2 shelvesIncludes 2 shelvesIncludes 2 shelves

Specifications are compiled from the supplied information. Confirm actual specifications, included accessories, controller version, and supplied configuration with the manufacturer or Fulcrum Technology.

Selection Guide

When selecting a chamber, first confirm sample dimensions and quantity, test temperature range, temperature ramp conditions, test duration, and whether multi-step programming is needed. For long-duration validation, special samples, or specific quality-control workflows, provide the sample information and test procedure for review.

Frequently Asked Questions

Q: What is a high and low temperature test chamber used for?

A: It simulates high, low, or changing temperature conditions for environmental testing of materials, electronic components, product stability, and quality-control validation.

Q: How do I choose between DCL-36, DCL-80, and DCL-120?

A: Choose based on sample dimensions, test capacity, chamber space, and workflow. Internal dimensions are 40 × 30 × 30 cm for DCL-36, 40 × 40 × 50 cm for DCL-80, and 50 × 40 × 60 cm for DCL-120.

Q: Which category is suitable for this equipment?

A: It belongs under constant temperature and humidity / environmental testing equipment because it focuses on high/low temperature simulation and environmental testing rather than simple drying or baking.

Q: What is the difference between a high and low temperature chamber and a temperature and humidity chamber?

A: A high and low temperature chamber focuses on high/low temperatures and temperature changes. A temperature and humidity chamber controls both temperature and humidity. If your test requires humidity, share the requirements to confirm suitable equipment.

Q: Can Fulcrum Technology confirm stock, lead time, and repair service?

A: Fulcrum Technology can help confirm stock, lead time, after-sales technical support, and repair services based on the model and requirements. Confirm the actual service details for the model, usage, and needs.

Need help confirming chamber specifications and model selection?

Share the test temperature range, sample dimensions, temperature ramp conditions, test duration, and application. Fulcrum Technology can help assess a suitable model and supply information.

Contact Fulcrum Technology for specifications and selection advice
top