High and Low Temperature Simulation
Supports testing under high, low, and changing temperature conditions to observe the stability and behavior of materials, components, or products in different temperature environments.
The DCL-36, DCL-80, and DCL-120 chambers simulate high, low, and changing temperature conditions for material and electronic component testing, product stability observation, R&D verification, and quality control. When selecting a model, first confirm the test temperature range, chamber capacity, sample dimensions, temperature ramp conditions, test duration, and whether programmable temperature control is required.
Fulcrum Technology can help assess a suitable high and low temperature test chamber for laboratories, R&D teams, and quality control based on product information and application needs. Confirm actual specifications, stock, lead time, and repair service details for the model and requirements.
Supports testing under high, low, and changing temperature conditions to observe the stability and behavior of materials, components, or products in different temperature environments.
Equipped with an imported computer-based programmable temperature controller. Test profiles can be set from 1 program with 15 steps up to 2 programs with 30 steps; confirm the actual configuration and controller version against the supplied unit.
The DCL series includes three models: DCL-36, DCL-80, and DCL-120. Select a suitable model based on sample dimensions, test capacity, chamber space, and workflow.
A multi-blade high-flow fan and long stainless-steel shaft circulate air. Safety features include power over-temperature protection and overload protection switches for the refrigeration unit and motor.
| Item | DCL-36 | DCL-80 | DCL-120 |
|---|---|---|---|
| Model | DCL-36 | DCL-80 | DCL-120 |
| Temperature Range | -40°C~+120°C | -40°C~+120°C | -40°C~+120°C |
| Temperature Accuracy | 0.2°C; temperature uniformity: 1–1.5°C at 100°C | 0.2°C; temperature uniformity: 1–1.5°C at 100°C | 0.2°C; temperature uniformity: 1–1.5°C at 100°C |
| Temperature Controller | Imported computer-based programmable temperature controller, 1 program with 15 steps to 2 programs with 30 steps | Imported computer-based programmable temperature controller, 1 program with 15 steps to 2 programs with 30 steps | Imported computer-based programmable temperature controller, 1 program with 15 steps to 2 programs with 30 steps |
| Control System | SSR control | SSR control | SSR control |
| Chamber Material | Stainless steel interior; galvanized steel exterior with powder coating | Stainless steel interior; galvanized steel exterior with powder coating | Stainless steel interior; galvanized steel exterior with powder coating |
| Circulation System | Multi-blade high-flow fan and long stainless-steel shaft for air circulation and even temperature distribution | Multi-blade high-flow fan and long stainless-steel shaft for air circulation and even temperature distribution | Multi-blade high-flow fan and long stainless-steel shaft for air circulation and even temperature distribution |
| Refrigeration Unit | Imported low-noise compressor | Imported low-noise compressor | Imported low-noise compressor |
| Internal Dimensions W × D × H | 40 × 30 × 30 cm | 40 × 40 × 50 cm | 50 × 40 × 60 cm |
| External Dimensions W × D × H | 64 × 83 × 130 cm | 64 × 93 × 155 cm | 74 × 93 × 165 cm |
| Safety Features | Power over-temperature protection; overload protection switches for refrigeration unit and motor | Power over-temperature protection; overload protection switches for refrigeration unit and motor | Power over-temperature protection; overload protection switches for refrigeration unit and motor |
| Accessories | Includes 2 shelves | Includes 2 shelves | Includes 2 shelves |
Specifications are compiled from the supplied information. Confirm actual specifications, included accessories, controller version, and supplied configuration with the manufacturer or Fulcrum Technology.
When selecting a chamber, first confirm sample dimensions and quantity, test temperature range, temperature ramp conditions, test duration, and whether multi-step programming is needed. For long-duration validation, special samples, or specific quality-control workflows, provide the sample information and test procedure for review.
A: It simulates high, low, or changing temperature conditions for environmental testing of materials, electronic components, product stability, and quality-control validation.
A: Choose based on sample dimensions, test capacity, chamber space, and workflow. Internal dimensions are 40 × 30 × 30 cm for DCL-36, 40 × 40 × 50 cm for DCL-80, and 50 × 40 × 60 cm for DCL-120.
A: It belongs under constant temperature and humidity / environmental testing equipment because it focuses on high/low temperature simulation and environmental testing rather than simple drying or baking.
A: A high and low temperature chamber focuses on high/low temperatures and temperature changes. A temperature and humidity chamber controls both temperature and humidity. If your test requires humidity, share the requirements to confirm suitable equipment.
A: Fulcrum Technology can help confirm stock, lead time, after-sales technical support, and repair services based on the model and requirements. Confirm the actual service details for the model, usage, and needs.
Share the test temperature range, sample dimensions, temperature ramp conditions, test duration, and application. Fulcrum Technology can help assess a suitable model and supply information.