Low-Temperature B.O.D. Incubator DBL-45 / DBL-150 / DBL-420

DBL Series Low-Temperature B.O.D. IncubatorThe DBL Series low-temperature incubator is designed for B.O.D. testing and controlled laboratory cultivation. The available product information lists DBL-45, DBL-150 and DBL-420 models and a temperature range of -10°C to 60°C. It may support biochemical experiments, cell and tissue culture, genetics research and other applications that require a stable, low-temperature chamber. Confirm the exact model configuration, chamber volume and operating conditions before ordering.ApplicationsUse a B.O.D. incubator when a laboratory protocol requires temperature-controlled incubation below or around ambient conditions. Typical workflows include B.O.D.-related testing, biochemical work, cultivation of cells or tissues, genetic studies and general laboratory incubation. Suitability depends on the sample, protocol, set point, loading pattern and required temperature stability; validate these conditions with the equipment supplier before starting a regulated or critical test.B.O.D. testing and related laboratory workflowsBiochemical experiments and sample incubationCell and tissue culture where the protocol calls for controlled low-temperature conditionsGenetics research and general laboratory cultivationModel selectionCompare DBL-45, DBL-150 and DBL-420 by the chamber capacity and internal dimensions specified for the offered configuration. Match the chamber to the largest sample, number of containers, shelf arrangement and clearance needed for air circulation. Also confirm the intended temperature range, recovery expectations after door opening, monitoring requirements and available laboratory space. Model numbers alone do not confirm a usable volume or performance specification.Product information to confirmItemAvailable information / selection noteProduct typeLow-temperature incubator / B.O.D. incubatorModels listedDBL-45, DBL-150, DBL-420Temperature range in supplied product information-10°C to 60°C; confirm the range for the selected model and configurationApplicationsB.O.D. testing, biochemical work, cell and tissue culture, genetics and general laboratory cultivationChamber volume, dimensions, shelves and electrical requirementsConfirm against the current manufacturer specification and quotationControl, alarm and monitoring functionsConfirm available functions and options for the supplied versionProduct details should be checked against the latest manufacturer documentation. The model name, accessories, controller, electrical supply and available options may vary by configuration or production version.Planning checklistDefine the protocol temperature, allowable variation, incubation duration and whether samples must remain below ambient temperature.Measure sample containers and determine the number of samples, shelf positions and clearance needed around each load.Choose a chamber size that accommodates the working load while allowing circulation; do not select by model number alone.Confirm room conditions, installation footprint, door access, power supply and any monitoring or alarm requirements.Ask the supplier to confirm model-specific specifications, accessories, delivery, warranty and service coverage before purchase.Frequently asked questionsWhat is a B.O.D. incubator used for?It provides a controlled-temperature chamber for B.O.D.-related tests and laboratory incubation. The exact suitability depends on the method and required set point; confirm compatibility with the protocol.What is the listed temperature range?The supplied product information lists -10°C to 60°C. Verify the operating range, uniformity and control performance for the exact model and configuration.How do I choose DBL-45, DBL-150 or DBL-420?Compare confirmed chamber volume and internal dimensions with sample size, quantity, shelf arrangement and required air circulation. Ask for the current model specification before deciding.Can it be used for cell or tissue culture?Cell and tissue culture are listed among the product applications. Confirm that the model, temperature conditions and any required contamination-control or monitoring practices meet your laboratory protocol.What should I confirm before ordering?Confirm the exact model, temperature performance, usable chamber volume, dimensions, electrical supply, included accessories, controller options, delivery and after-sales service.Need help selecting a model?Share your protocol temperature, sample dimensions, quantity, required chamber capacity, available space and power conditions. Contact Fulcrum Technology for model and specification confirmation.

Low-Temperature Constant-Temperature Incubator / B.O.D. Incubator

The low-temperature constant-temperature incubator / B.O.D. incubator is suitable for laboratory applications such as BOD testing, biochemical work, cell and tissue culture, genetics, and general cultivation. When selecting a model, first confirm the required temperature range, capacity, interior dimensions, sample quantity, culture conditions, and whether long-term stable operation is needed; then compare models such as DBL-45, DBL-60, and DBL-120.

Fulcrum Technology can help assess low-temperature incubation equipment for laboratories, R&D units, schools, quality-control work, and testing workflows based on product information and your application. Please confirm specifications, stock, lead time, and repair services for the specific model and requirements.

Low-Temperature Incubator B.O.D. Incubator BOD Testing Biochemical Laboratory Cell and Tissue Culture

BOD Testing and Culture Applications

For BOD testing, biochemical work, cell and tissue culture, genetics, and other applications that require low or stable temperatures.

Select by Capacity

The DBL series includes DBL-45, DBL-60, and DBL-120 models with capacities of 72 L, 150 L, and 420 L, respectively. Select a model based on sample quantity, container size, shelf requirements, and available laboratory space.

Low-Temperature and Constant-Temperature Control

The low-temperature incubator operates from -10°C to 60°C. A 0°C to 60°C range is available for the B.O.D. incubator to accommodate different culture and storage conditions.

Designed for Laboratory Use

The unit features a stainless-steel interior, powder-coated galvanized-steel exterior, PU foam insulation, gentle-air circulation, and protective devices for laboratory and quality-control workflows.

Specifications

ModelDBL-45DBL-60DBL-120
ApplicationsBOD testing, biochemical work, cell and tissue culture, genetics, and cultivation
Temperature Range-10°C to 60°C; 0°C to 60°C is available for the B.O.D. incubator
Temperature ControllerFull touch panel, imported microcomputer PID auto-tuning temperature controller, and SSR control
Temperature Accuracy±0.1°C
Temperature DisplayLED digital display, 0.1°C resolution
Temperature SensorPT100Ω platinum temperature probe
MaterialsStainless-steel interior and powder-coated galvanized-steel exterior
Air CirculationGentle-air circulation for even temperature distribution inside the chamber
Safety ProtectionPower protection switch and over-temperature protector
Cooling SystemImported fully enclosed refrigeration compressor with quiet operation
InsulationPU foam insulation for effective temperature retention
Capacity72 L150 L420 L
Interior Dimensions W × D × H450 × 400 × 400 mm600 × 500 × 500 mm700 × 500 × 1200 mm
Exterior Dimensions W × D × H560 × 550 × 880 mm710 × 650 × 1030 mm810 × 720 × 1720 mm
Heater450 W800 W1600 W
Compressor1/4 HP1/3 HP1/2 HP
Power Supply110 / 220 V,8 A / 4 A110 / 220 V,12 A / 6 A110 / 220 V,18 A / 9 A
Accessories2 movable shelves2 movable shelves5 movable shelves

Other configurations, including -10°C, below -40°C, or ultra-low-temperature incubators, may be available from the manufacturer. For special low-temperature requirements, provide the operating temperature, capacity, and sample conditions for confirmation.

Specifications are compiled from manufacturer and product information. Confirm the actual specifications, included accessories, controller version, and supplied configuration with Fulcrum Technology.

Model Selection

When selecting a low-temperature constant-temperature or B.O.D. incubator, confirm the operating temperature, sample quantity, container dimensions, capacity, shelf requirements, culture duration, and whether it will be used for BOD testing. If the sample, culture, or quality-control workflow has special requirements, provide the application details for confirmation.

Frequently Asked Questions

Q: What are the main uses of a low-temperature incubator?

A:Low-temperature incubators are used for culture and storage processes requiring low or stable temperatures, including BOD testing, biochemical work, cell and tissue culture, genetics, and general cultivation.

Q: How should I choose between DBL-45, DBL-60, and DBL-120?

A:Choose based on capacity, interior dimensions, sample quantity, and shelf requirements. DBL-45 has a 72 L capacity, DBL-60 has 150 L, and DBL-120 has 420 L.

Q: What is the difference between a B.O.D. incubator and a low-temperature incubator?

A:A B.O.D. incubator is generally used to control culture conditions for BOD testing. A low-temperature constant-temperature incubator can be used for low-temperature culture, biochemical experiments, or sample storage, depending on the application. Confirm the model based on the test objective.

Q: Are incubators below -40°C or ultra-low-temperature models available for evaluation?

A:The manufacturer may offer configurations at -10°C, below -40°C, or ultra-low-temperature incubators. For special low-temperature requirements, provide the operating temperature, capacity, and sample conditions for confirmation.

Q: Can Fulcrum Technology confirm stock, lead time, and repair services?

A:Fulcrum Technology can help confirm stock, lead time, after-sales technical support, and repair services based on the model and your needs. Actual service availability depends on the model, operating condition, and requirements.

Need help confirming incubator specifications and model selection?

Provide the operating temperature, sample dimensions, capacity, culture conditions, and whether the unit is for BOD testing. Fulcrum Technology can help assess a suitable model and availability.

Contact Fulcrum Technology for specifications and model selection advice
top