BOD Testing and Culture Applications
For BOD testing, biochemical work, cell and tissue culture, genetics, and other applications that require low or stable temperatures.
The low-temperature constant-temperature incubator / B.O.D. incubator is suitable for laboratory applications such as BOD testing, biochemical work, cell and tissue culture, genetics, and general cultivation. When selecting a model, first confirm the required temperature range, capacity, interior dimensions, sample quantity, culture conditions, and whether long-term stable operation is needed; then compare models such as DBL-45, DBL-60, and DBL-120.
Fulcrum Technology can help assess low-temperature incubation equipment for laboratories, R&D units, schools, quality-control work, and testing workflows based on product information and your application. Please confirm specifications, stock, lead time, and repair services for the specific model and requirements.
For BOD testing, biochemical work, cell and tissue culture, genetics, and other applications that require low or stable temperatures.
The DBL series includes DBL-45, DBL-60, and DBL-120 models with capacities of 72 L, 150 L, and 420 L, respectively. Select a model based on sample quantity, container size, shelf requirements, and available laboratory space.
The low-temperature incubator operates from -10°C to 60°C. A 0°C to 60°C range is available for the B.O.D. incubator to accommodate different culture and storage conditions.
The unit features a stainless-steel interior, powder-coated galvanized-steel exterior, PU foam insulation, gentle-air circulation, and protective devices for laboratory and quality-control workflows.
| Model | DBL-45 | DBL-60 | DBL-120 |
|---|---|---|---|
| Applications | BOD testing, biochemical work, cell and tissue culture, genetics, and cultivation | ||
| Temperature Range | -10°C to 60°C; 0°C to 60°C is available for the B.O.D. incubator | ||
| Temperature Controller | Full touch panel, imported microcomputer PID auto-tuning temperature controller, and SSR control | ||
| Temperature Accuracy | ±0.1°C | ||
| Temperature Display | LED digital display, 0.1°C resolution | ||
| Temperature Sensor | PT100Ω platinum temperature probe | ||
| Materials | Stainless-steel interior and powder-coated galvanized-steel exterior | ||
| Air Circulation | Gentle-air circulation for even temperature distribution inside the chamber | ||
| Safety Protection | Power protection switch and over-temperature protector | ||
| Cooling System | Imported fully enclosed refrigeration compressor with quiet operation | ||
| Insulation | PU foam insulation for effective temperature retention | ||
| Capacity | 72 L | 150 L | 420 L |
| Interior Dimensions W × D × H | 450 × 400 × 400 mm | 600 × 500 × 500 mm | 700 × 500 × 1200 mm |
| Exterior Dimensions W × D × H | 560 × 550 × 880 mm | 710 × 650 × 1030 mm | 810 × 720 × 1720 mm |
| Heater | 450 W | 800 W | 1600 W |
| Compressor | 1/4 HP | 1/3 HP | 1/2 HP |
| Power Supply | 110 / 220 V,8 A / 4 A | 110 / 220 V,12 A / 6 A | 110 / 220 V,18 A / 9 A |
| Accessories | 2 movable shelves | 2 movable shelves | 5 movable shelves |
Other configurations, including -10°C, below -40°C, or ultra-low-temperature incubators, may be available from the manufacturer. For special low-temperature requirements, provide the operating temperature, capacity, and sample conditions for confirmation.
Specifications are compiled from manufacturer and product information. Confirm the actual specifications, included accessories, controller version, and supplied configuration with Fulcrum Technology.
When selecting a low-temperature constant-temperature or B.O.D. incubator, confirm the operating temperature, sample quantity, container dimensions, capacity, shelf requirements, culture duration, and whether it will be used for BOD testing. If the sample, culture, or quality-control workflow has special requirements, provide the application details for confirmation.
A:Low-temperature incubators are used for culture and storage processes requiring low or stable temperatures, including BOD testing, biochemical work, cell and tissue culture, genetics, and general cultivation.
A:Choose based on capacity, interior dimensions, sample quantity, and shelf requirements. DBL-45 has a 72 L capacity, DBL-60 has 150 L, and DBL-120 has 420 L.
A:A B.O.D. incubator is generally used to control culture conditions for BOD testing. A low-temperature constant-temperature incubator can be used for low-temperature culture, biochemical experiments, or sample storage, depending on the application. Confirm the model based on the test objective.
A:The manufacturer may offer configurations at -10°C, below -40°C, or ultra-low-temperature incubators. For special low-temperature requirements, provide the operating temperature, capacity, and sample conditions for confirmation.
A:Fulcrum Technology can help confirm stock, lead time, after-sales technical support, and repair services based on the model and your needs. Actual service availability depends on the model, operating condition, and requirements.
Provide the operating temperature, sample dimensions, capacity, culture conditions, and whether the unit is for BOD testing. Fulcrum Technology can help assess a suitable model and availability.