NH310 Horizontal Colorimeter (Dual Φ8 mm / Φ4 mm Apertures)

NH310 Horizontal Colorimeter offers Φ8 mm and Φ4 mm measuring apertures with alignment and camera positioning. It supports small-area sample measurement, routine color comparison, CIE LAB, XYZ and LCh data, and ΔE evaluation. Suitable for incoming inspection, in-process checks and routine quality control across food, printing, textiles, coatings, construction, automotive, cosmetics, industrial materials and inks. Confirm the configuration against the sample material, surface, measurement area and quality-control workflow.

 
Product Introduction

NH310 Horizontal Colorimeter | Dual Apertures, Small-Area Positioning and Routine Color QC

NH310 horizontal colorimeter is a portable colorimeter for on-site QC, incoming inspection, in-process checks and sample comparison. Manufacturer information describes a multi-channel color sensor, stable IC platform and color algorithms that provide CIE Lab, XYZ, LCh, CIE RGB and CIE LUV data for ΔE color-difference evaluation.

Its key strengths are dual apertures and positioning support. The Φ8 mm aperture is suited to general flat samples and larger comparison areas; Φ4 mm supports small measurement areas, local color patches and details that are difficult to align. Camera-view and illuminated positioning help identify the test point. Confirm fit against sample material, surface condition, measurement area, color uniformity and the QC workflow.

Measurement Design

From quick comparison to small-area positioning

Evaluate NH310 for routine color comparison, dual-aperture checks, small-area positioning and computer-based data management.

01

D/8 Geometry for Routine Color Comparison

The D/8 measurement geometry supports color comparison between reference and test samples across plastics, coatings, inks, printing, automotive parts, textiles, food, building materials and routine QC.

For glossy, directional-texture, transparent or translucent samples, confirm measurement conditions and acceptance criteria before use.

02

Dual Φ8 mm / Φ4 mm Apertures

Choose the Φ8 mm aperture for general flat samples and larger measurement areas, or Φ4 mm for small color patches, details and locations that are difficult to align.

For recessed, curved or irregular surfaces, evaluate fixtures, instrument angle and sample holding to reduce repeatability errors.

03

Camera and Illuminated Positioning

Camera-view and illuminated positioning help operators locate the measurement point, especially on small samples, localized print or coating areas, plastic parts, textile patterns and specified test locations.

The manufacturer describes camera positioning for small areas down to about 4 mm wide; actual capability depends on sample shape, reflectance, working distance and ambient light.

04

Automatic Black-and-White Calibration

Automatic black-and-white calibration at startup helps establish a routine pre-measurement check and reduces the risk of missing a calibration step.

For a controlled QC workflow, define calibration intervals, white-tile care, pre-test checks and recordkeeping in the applicable SOP.

05

CQCS3 Software for Color Data Management

Optional CQCS3 quality-management software supports color-difference analysis, colorimetric indices, sample-database management and measurement records.

For custom reports, database connections, ERP/MES integration or automated decisions, assess the requirements against the site system architecture.

06

Portable, Rechargeable Design

A rechargeable lithium battery and portable body support checks in laboratories, production lines, warehouses, supplier inspections and customer sites.

Actual operating time varies with battery condition, screen brightness, measurement frequency and use conditions.

Applications

Potential NH310 Applications

Plastics and Electronic Parts

Compare housings, buttons, molded parts, coated parts and small components.

Coatings, Inks and Printing

Compare reference and production samples to support color matching and batch control.

Textiles and Apparel

Assess fabric, dyed swatches, printed regions and incoming materials as an initial color-difference check.

Food, Building Materials and Consumer Goods

Support routine QC comparisons of packaging, coatings, finished surfaces and customer samples.

Selection Guide

When is NH310 worth evaluating?

Use caseNH310 evaluation point
General and small-area samplesEvaluate the dual Φ8 mm / Φ4 mm design and select the aperture based on sample area.
Hard-to-align measurement pointsCamera and illuminated positioning can help locate the test point on a local color patch or specified region.
Fast operation by on-site staffThe intuitive interface and startup calibration workflow support routine use.
Color records and sample databaseCQCS3 software can assist with color-data analysis and management.
Full spectral data or stricter supply-chain acceptanceConsider a spectrophotometer and confirm the applicable standards, acceptance limits and QC process.

Before implementation

NH310 is intended for dual-aperture color comparison, small-area positioning, incoming inspection, process checks and routine QC. Confirm sample material, gloss, texture direction, measurement area, aperture, positioning, calibration and internal acceptance limits. If full spectral data, multiple illuminants, supply-chain traceability or more rigorous comparison is required, consider a spectrophotometer.

Contact Fulcrum Technology about NH310 selection and applications


 
Technical Specifications

NH310 Horizontal Colorimeter Specifications

Use these specifications as a reference when evaluating the NH310 for selection, purchasing and deployment. The NH310 uses D/8 geometry, Φ4 mm / Φ8 mm apertures, SCI/SCE modes and camera positioning. It may be considered for small-area positioning, color comparison, incoming inspection, in-process checks and routine QC. Confirm suitability for the sample material, surface condition, measurement area, color uniformity and workflow.

Product ModelNH310 Colorimeter
Measurement GeometryD/8 (diffuse illumination, 8° directional viewing, including specular component SCI); conforms to CIE No. 15 and GB/T 3978.
DetectorSilicon photodiode array
Spectral MethodNot applicable
Integrating Sphere SizeΦ40 mm
Illumination SourceFull-spectrum LED
Measurement Wavelength RangeNot applicable
Observer IlluminantsD65, A, D50
Wavelength IntervalNot applicable
Reflectance RangeNot applicable
Measurement AperturesΦ4 mm, Φ8 mm
Specular Component ModesSCI / SCE
Color SpacesCIE LAB, XYZ, LCh, CIE RGB, CIE LUV
Color-Difference FormulasΔE*ab, ΔE(h), ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00
Other Colorimetric IndicesYellowness, whiteness, staining fastness and color-change fastness
Observer Angle10°
Displayed ParametersSample color values, color difference, pass/fail result and color tendency
Measurement TimeApprox. 1.5 s
RepeatabilityΔE*ab ≤ 0.06 (after warm-up and calibration; average of 30 white-tile measurements at 5-second intervals)
Inter-Instrument DifferenceΔE*ab ≤ 0.4 (average across measurements of 12 BCRA Series II color tiles)
Measurement ModeSingle measurement
PositioningAlignment and camera positioning
Dimensions205 × 70 × 100 mm
WeightApprox. 400 g
BatteryRechargeable lithium battery
Light-Source LifetimeApprox. 5 years or more than 1.6 million measurements
Display2.8-inch TFT full-color screen
ConnectionUSB
Data Storage100 reference samples; 20,000 test samples
Software SupportCQCS3 quality-management software
LanguagesTraditional Chinese, Simplified Chinese and English
Operating Conditions0–40°C; 0–85% relative humidity (non-condensing)
Storage Temperature−20–50°C (non-condensing)
Standard AccessoriesPower adapter, manual, white calibration box, data cable, CQCS3 software (download from the official website), Φ4 mm and Φ8 mm apertures, and lithium battery
Optional AccessoriesMini printer, powder test box and multifunctional test kit
NoteSpecifications may change. Confirm the latest information with Fulcrum Technology or the manufacturer before ordering.

Selection note: The NH310 is suited to dual-aperture comparison, small-area positioning and routine QC. Before implementation, confirm sample material, gloss, texture direction, measurement area, aperture, positioning, calibration and acceptance criteria. For full spectral data, multiple illuminants or supply-chain color traceability, consider a spectrophotometer.

top