TS7600 Spectrophotometer
Product Overview
TS7600 Spectrophotometer | D/8, SCI/SCE and Color Quality Control
TS7600 spectrophotometer uses D/8 geometry and supports SCI/SCE measurement, UV-included / UV-excluded measurement, a full-spectrum combined LED source, dual optical paths and a silicon photodiode array for applications requiring spectral reflectance, color data and quality-control traceability.
The TS7600 can be used in plastics, coatings, inks, textiles and dyeing, printing, ceramics, and electronic materials for Lab color data and ΔE difference assessment, incoming inspection, R&D comparison and process quality control. Selection should be confirmed against sample size, surface condition, measurement area, gloss, fluorescence conditions and internal QC procedures.
Key Features
TS7600 spectrophotometer features
Designed for SCI/SCE comparison, UV condition evaluation, spectral data measurement, data storage and color quality management.
D/8 geometry
Uses D/8 geometry and meets relevant measurement conditions in CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164 and DIN 5033 Teil 7 for color QC and R&D comparison.
Full-spectrum LED source and UV conditions
The long-life, low-power combined full-spectrum LED source supports UV-included / UV-excluded measurement to help evaluate color differences in fluorescent or optical-brightener-containing samples.
Dual optical paths and SCI/SCE spectra
The dual optical path system supports spectral measurement in the visible range and can measure sample SCI and SCE spectra simultaneously, helping compare how surface gloss, texture or specular reflection affects color assessment.
Spectral data and Lab color data
Measures sample spectra and Lab color data for formulation, batch comparison, supply-chain acceptance and color communication. Final decisions should follow internal acceptance criteria and QC procedures.
3.5-inch touchscreen and hardware
Equipped with a 3.5-inch TFT color display, capacitive touchscreen, 1000-line blazed grating and a silicon photodiode array detector with a large photosensitive area for convenient operation and data viewing.
USB and Bluetooth communication
Supports USB and Bluetooth for data transfer and management in field inspection, laboratory workflows or QC reporting. Available functions should be confirmed for the supplied hardware and software versions.
Standard white tile
Includes a standard white tile for routine calibration and measurement workflows. Storage and calibration should follow the manufacturer’s procedures.
Large data storage
Stores more than 30,000 measurement records, supporting batch tracking, incoming inspection records and long-term QC data management.
Multiple illuminants, color spaces and indices
Supports 2° / 10° standard observer angles, multiple illuminant modes, color spaces and colorimetric indices aligned with multiple standards for different industry workflows.
Camera viewfinder and positioning plate
Camera viewing and a positioning plate help operators confirm measurement location and reduce variation caused by sample-position shifts.
PC software expansion
Optional PC software can support color-data management, color-difference comparison and report organization for incoming inspection, batch comparison and process QC. Software functions, export formats and data-management items should be confirmed for the supplied version.
Selection Guide
How to distinguish the TS7600 from other high-end spectrophotometers
Compare UV conditions, aperture configuration, sample size, data-management needs and field measurement requirements.
TS7600 | D/8, UV and SCI/SCE color QC
For D/8 geometry, SCI/SCE, UV-included / UV-excluded measurement, spectral data and QC traceability, consider the TS7600 spectrophotometer.
TS7700 | Dual apertures and UV conditions
For MAV / SAV dual apertures, Φ8 mm and Φ4 mm switching, UV conditions and data management, compare the TS7700 spectrophotometer.
FTZ Series | Handheld multi-aperture field measurement
For handheld multi-aperture inspection, field rounds or varying measurement points, compare FTZ7, FTZ8 or FTZ9.
FTS7000 / Aurora | More apertures and special samples
For samples with a wide range of sizes, special measurement points or higher-end multi-aperture configurations, compare the FTS7000 spectrophotometer or Aurora array spectrophotometer.
FAQ
Frequently asked questions about the TS7600
Review these points before introducing the TS7600 into D/8, SCI/SCE, UV and color-QC workflows.
What samples and industries is the TS7600 suitable for?
It can be considered for plastics, coatings, inks, textile dyeing, printing, ceramics, electronic materials and laboratory R&D/QC. Confirm suitability based on sample size, surface condition, measurement area and QC workflow.
What are the TS7600 UV conditions used for?
UV-included / UV-excluded measurement can help evaluate color differences in fluorescent or optical-brightener-containing samples under different UV conditions. For fluorescent materials, textiles, paper or special coatings, confirm customer acceptance conditions and measurement standards first.
What is the purpose of SCI/SCE measurement?
SCI/SCE measurement helps compare color data with and without the effect of surface specular reflection. For glossy, matte, coated, textured or otherwise different surfaces, confirm whether SCI, SCE or both must be recorded under the acceptance requirements.
How is the TS7600 different from a basic colorimeter?
A basic colorimeter is often used for quick color-difference checks. The TS7600 is a spectrophotometer that can provide spectral reflectance, Lab color data, ΔE assessment and multiple colorimetric indices for R&D, supply-chain acceptance and QC traceability.
How should I choose between the TS7600 and TS7700?
For D/8, SCI/SCE, UV conditions and general color-QC traceability, evaluate the TS7600. If you need explicit MAV / SAV dual-aperture switching and different measurement areas, compare the TS7700. Base the final choice on the samples and inspection purpose.
What information should be provided before implementing the TS7600?
Provide sample material and dimensions, measurement spot size, surface gloss, texture or curvature, fluorescence or optical brighteners, the color-difference formula, observer illuminant, acceptance limits, SCI/SCE or UV requirements, and data-retention and reporting needs.
Pre-deployment checks
For fluorescent or brightened samples, small areas, curved or textured surfaces, gloss differences or multiple suppliers, provide sample details, inspection purpose and internal criteria, then confirm the aperture, UV conditions, SCI/SCE settings and data-management approach for the TS7600.
Contact Fulcrum Technology for selection adviceTS7600 Spectrophotometer Specifications
The following specifications are based on current TS7600 product information for evaluation, purchasing and QC planning. TS7600 uses one aperture configuration; consider MAV: Φ8 mm / Φ10 mm or SAV: Φ4 mm / Φ5 mm. Confirm the supplied aperture and application conditions based on sample size, measurement area, surface condition and QC workflow.
| Product model | TS7600 Spectrophotometer |
|---|---|
| Measurement geometry | D/8 (diffuse illumination, 8° viewing); SCI/SCE measurement; UV included / UV excluded measurement; conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164 and DIN 5033 Teil7 |
| Detector | Silicon photodiode (dual row, 40 groups) |
| Spectral separation | Plane grating |
| Integrating sphere size | Φ40 mm |
| Illumination source | Combined full-spectrum LED source and UV source |
| Measurement wavelength range | 400–700 nm |
| Observer illuminants | D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30) |
| Wavelength interval | 10 nm |
| Reflectance measurement range | 0–200% |
| Measurement aperture | Single aperture: MAV Φ8 mm / Φ10 mm or SAV Φ4 mm / Φ5 mm. Confirm during selection according to sample size and measurement area. |
| Specular component mode | Simultaneous SCI / SCE measurement |
| Color spaces | CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy, DIN Lab99, Munsell (C/2) |
| Color-difference formulas | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE (Hunter) |
| Other colorimetric indices | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), metamerism index Mt, staining fastness, color-change fastness, color strength, opacity, 8° gloss, 555 hue classification |
| Observer angles | 2° / 10° |
| Displayed parameters | Spectrum graph / data, sample color values, color-difference values / graph, pass / fail result, color simulation and color tendency |
| Measurement time | Approximately 1.5 seconds |
| Repeatability | Spectral reflectance: MAV / SCI, standard deviation within 0.08% (400–700 nm: within 0.18%) |
| Inter-instrument difference | MAV / SCI, ΔE*ab within 0.15 (average of 12 BCRA Series II tiles) |
| Measurement modes | Single measurement and average measurement (2–99 times) |
| Positioning | CCD viewfinder positioning and alignment plate positioning |
| Dimensions | 129 × 76 × 217 mm (H × W × D) |
| Weight | 600 g |
| Battery | Lithium battery, 3.7 V, 5000 mAh; up to 6,000 measurements within 8 hours |
| Illumination lamp life | Approximately 5 years, more than 1.5 million measurements |
| Display | 3.5-inch TFT color display with capacitive touchscreen |
| Connectivity | USB, Bluetooth 4.2 |
| Data storage | 1,000 standards and 30,000 samples (one record can include both SCI / SCE) |
| Software support | Windows, Android, iOS |
| Languages | Traditional Chinese, Simplified Chinese, English |
| Operating temperature | 0–40°C, 0–85% relative humidity (non-condensing) |
| Storage temperature | -20–50°C (non-condensing) |
| Standard accessories | Power adapter, data cable, manual, quality-management software (download from official website), black-and-white calibration box, protective cover, wrist strap, Ø8 mm or Ø4 mm platform aperture |
| Optional accessories | Mini printer, powder test box |
Specification note: TS7600 is a single-aperture spectrophotometer for color-QC workflows with a fixed sample size or measurement area. For fluorescent or brightened samples, small areas, curved or textured surfaces, gloss differences or multiple suppliers, provide sample information to confirm the aperture, SCI/SCE conditions, UV conditions and data-management approach. Specifications are compiled from current product information; confirm the actual supplied version with the manufacturer or Fulcrum Technology.