Spectrophotometer NS800
NS800 Spectrophotometer | 45°/0° Geometry, Lab Color Data, and Color-Difference Quality Control
NS800 spectrophotometerFeaturing 45°/0° geometry with 45° circumferential illumination and 0° viewing, the NS800 is suitable for quality control, R&D, and production teams. It supports Lab color data and △E color difference evaluation, reflectance measurement, incoming inspection, in-process checks, and batch color comparison.
The NS800 is suited to color quality control in plastics, coatings, inks, textiles, printing, packaging, and general manufacturing. If comparing 45°/0° with D/8 geometry or testing glossy, textured, or specially finished samples, confirm the applicable standards, sample conditions, and internal evaluation process before selecting a model.
NS800 Spectrophotometer Features
Designed for 45°/0° measurements, color data evaluation, reflectance analysis, and PC-based data management.
Ergonomic Design
The NS800 features a handheld form and an operating-friendly design for on-site testing, incoming inspection, laboratory comparison, and routine quality control.
45°/0° Measurement Geometry
Its 45°/0° optical geometry can be evaluated against your quality standards and customer acceptance requirements for the intended color measurement process.
3.5-Inch Capacitive Touchscreen
The 3.5-inch capacitive touchscreen lets operators view colorimetric values, color differences, and evaluation results for efficient routine testing.
Multiple Observer Angles and Illuminants
It supports 2°/10° observer angles and multiple illuminant modes to meet different industry standards, sample conditions, and color evaluation needs.
Repeatability and Instrument-to-Instrument Agreement
Specifications indicate repeatability within ΔE*ab 0.04 and inter-instrument difference within ΔE*ab 0.2, guiding instrument comparison and long-term quality monitoring.
Large Data Storage Capacity
It stores more than 10,000 test results to support reference and sample records, batch tracking, supplier inspection, and production quality management.
PC Software Capabilities
Optional PC software can organize and compare color data and manage reports. Confirm the available functions and compatibility with the supplied version.
Enhanced Hardware Configuration
The full-spectrum LED source, spectroscopic components, color display, and data management features support workflows that need stable color data and convenient on-site operation.
Large Integrating Sphere
The larger integrating sphere helps distribute light evenly and supports stable measurements when comparing materials, batches, and suppliers.
15° Screen Tilt
The tilted screen is easy to view during handheld testing, helping operators check data, results, and sample information quickly.
NS800 Frequently Asked Questions
Answers to common questions about NS800 45°/0° geometry, Lab color data, quality-control implementation, and model selection.
Which industries can use the NS800?
The NS800 can be considered for color testing in plastics, coatings, inks, textiles, printing, packaging, and general manufacturing. It supports incoming inspection, process checks, R&D comparisons, and batch color-difference management. Confirm suitability based on the sample material, surface condition, and internal quality standards.
When is the NS800’s 45°/0° geometry suitable?
45°/0° geometry is used for color comparisons under specific visual conditions or customer acceptance procedures. For glossy, textured, coated, or printed surfaces, confirm whether the customer specification requires 45°/0° or D/8 before selecting a model.
Can the NS800 measure Lab values and △E color differences?
The NS800 supports Lab color data and △E evaluation for reference and sample measurements, tolerance limits, and batch comparisons. To establish internal quality standards, confirm illuminant conditions, observer angle, color-difference formula, and acceptance limits.
Is the NS800 suitable for glossy or textured samples?
It may be suitable, but gloss, texture, curved surfaces, or special coatings can affect measurement stability and data interpretation. Review actual sample conditions to determine whether 45°/0° geometry is appropriate or another spectrophotometer geometry should be considered.
How does the NS800 differ from a D/8 spectrophotometer?
The NS800 uses 45°/0° geometry, while a D/8 spectrophotometer uses diffuse illumination and 8° viewing. Their responses to gloss, surface texture, and appearance can differ; select according to customer requirements, industry standards, and sample conditions.
What information should I prepare before adopting the NS800?
Provide the sample material and dimensions, measurement spot size, surface gloss, texture or curvature, current color-difference formula, illuminant, acceptance criteria, any customer-specified geometry, and reporting or traceability needs.
Checks Before Implementation
For samples with varying gloss, texture, curved or small areas, halftone printing, special coatings, or customer-specified conditions, first confirm whether 45°/0° or D/8 geometry is required. Then verify that the NS800 fits your samples, test objectives, and quality-control workflow.
Contact Fulcrum Technology for model selection adviceNS800 Spectrophotometer Specifications
The specifications below can support NS800 model selection, procurement, and quality-control planning. The NS800 uses 45°/0° measurement geometry, an Φ8 mm aperture, Lab color data, ΔE color-difference evaluation, reflectance measurement, 2°/10° observer angles, and Windows software for data management. It is suitable for incoming inspection, in-process checks, R&D comparisons, and batch color-difference management. Confirm the final selection based on sample size, surface condition, gloss variation, applicable test standards, and your internal quality-control workflow.
| Product Model | NS800 Spectrophotometer |
|---|---|
| Measurement Geometry | 45°/0° (45° uniform circumferential illumination, 0° viewing); compliant with CIE No. 15 and GB/T 3978 |
| Detector | Silicon photodiode array |
| Spectral System | Plane grating |
| Integrating Sphere Size | Φ58 mm |
| Illumination Source | Combined full-spectrum LED source |
| Wavelength Range | 400–700 nm |
| Illuminants | D65, A, F2 (CWF) |
| Resolution | 0.01 |
| Wavelength Interval | 10 nm |
| Reflectance Range | 0–200% |
| Measurement Aperture | Φ8 mm |
| Measurement Mode | SCI |
| Color Spaces | CIE LAB, XYZ, Yxy, LCh, CIE LUV |
| Color-Difference Formulas | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00 |
| Other Colorimetric Indices | WI(ASTM E313, CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), TI(ASTM E313, CIE/ISO), metamerism index Mt, tint strength, staining, color fastness, and opacity |
| Observer Angles | 2°/10° |
| Displayed Parameters | Reflectance (at 3 user-selected wavelengths), sample colorimetric values, color difference/value graph, pass/fail result, color simulation, and color cast |
| Measurement Time | Approx. 1.5 s |
| Repeatability | Spectral reflectance: standard deviation within 0.1% (within 0.2% at 400–700 nm); colorimetric value: ΔE*ab within 0.04 after calibration (average of 30 white-tile measurements at 5-second intervals) |
| Inter-Instrument Agreement | ΔE*ab within 0.2 (average measured across 12 BCRA Series II color tiles) |
| Measurement Method | Not specified |
| Positioning Method | Stable plate positioning |
| Dimensions | Length × width × height = 90 × 77 × 230 mm |
| Weight | 600 g |
| Battery | Rechargeable lithium battery |
| Lamp Life | Approx. 5 years or more than 1.5 million measurements |
| Display | 3.5-inch TFT color capacitive touchscreen |
| Connectivity | USB, RS232 |
| Data Storage | 1,000 standards and 15,000 samples |
| Software | Windows |
| Languages | Traditional Chinese, Simplified Chinese, English |
| Operating Conditions | 0–40°C; 0–85% relative humidity, non-condensing |
| Storage Conditions | -20–50°C, non-condensing |
| Standard Accessories | Power adapter, data cable, manual, black-and-white calibration box, protective cover, wrist strap, and lithium battery |
| Optional Accessories | Multifunction test fixture (for liquids, powders, granules, etc.), mini printer, and powder test box |
Specification note: The NS800 uses 45°/0° geometry, which differs from common D/8 spectrophotometers. For samples with gloss, texture, halftone printing, special coatings, or customer-specified standards, first confirm whether 45°/0° or D/8 is required, then select the appropriate model based on the sample conditions, test objectives, and quality-control workflow.