Dual-row 26-element sensor array
The large-area photodiode array uses two rows of 26 elements to support stable signal collection and consistent color comparison in routine quality-control and R&D workflows.
The ST60 spectrophotometer offers four measurement apertures to help match sample size, measurement location and surface condition. It is suitable for color-data and ΔE difference evaluation, incoming inspection, R&D comparison, process checks and batch color management.
ST60 supports color measurement and quality control for plastics and electronics, paints and inks, textiles, printing and paper, ceramics and laboratory R&D. It can also be considered for an initial evaluation of fluorescent samples. Confirm sample size, surface, measured area, gloss, fluorescence, aperture needs and internal QC workflow before selection.
Before adopting ST60, share sample material and dimensions, surface condition, inspection purpose, acceptance criteria and data-management needs so Fulcrum Technology can help confirm the model and measurement conditions.
Designed for multi-aperture measurement, color-difference evaluation, fluorescent-sample assessment and industrial quality-control workflows.
The large-area photodiode array uses two rows of 26 elements to support stable signal collection and consistent color comparison in routine quality-control and R&D workflows.
D/8 illumination and viewing geometry supports SCI/SCE measurements and simultaneous SCI+SCE capture, helping compare color with and without the specular component.
Full-spectrum LED illumination across 360–700 nm is combined with a UV source for evaluation of fluorescent samples, optical brighteners and color under different illumination conditions.
Standard apertures include Φ8 mm flat, Φ8 mm pointed, Φ4 mm flat and Φ4 mm pointed options for different sample sizes and measurement locations.
The built-in camera helps operators position the measurement area on small or localized sample regions and repeat measurements at consistent points.
A non-contact calibration workflow and standard white tile support consistent daily measurement conditions. Follow the supplier guidance for calibration frequency and procedure.
The placement base helps protect the instrument contact surface and calibration white tile during routine storage, handling and calibration.
Supports CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy, DIN Lab99 and Munsell color spaces, with a broad selection of illuminants.
Data workflows can include spectral reflectance, whiteness, yellowness, metamerism, colorfastness, color strength, opacity and color density; software support may be required for some functions.
ST60 can support evaluation of repeatability and consistency across instruments. Actual performance depends on samples, calibration and operating conditions.
Depending on the supplied software version, mobile applications can help organize color records, compare batches and document on-site quality checks.
Use these specifications as a reference for ST60 selection, procurement and quality-control planning. Confirm sample and workflow requirements before final configuration.
| Specification | Details |
|---|---|
| Product model | 3nh ST60 Spectrophotometer |
| Illumination geometry | D/8 (diffuse illumination, 8° directional reception); SCI/SCE; includes/excludes UV measurement; conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164 and DIN 5033 Part 7 |
| Integrating sphere diameter | Φ40 mm |
| Illumination source | Combined full-spectrum LED and UV sources |
| Spectral method | Planar grating |
| Detector | Large-area silicon photodiode array (two rows of 26 elements) |
| Wavelength range | 360–700 nm |
| Wavelength interval | 10 nm |
| Reflectance range | 0–200% |
| Measurement apertures | Four apertures: MAV Φ8 mm / Φ10 mm; SAV Φ4 mm / Φ5 mm |
| Measurement mode | Simultaneous SCI / SCE measurement |
| Color spaces | CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy, DIN Lab99, Munsell (C/2) |
| Color-difference formulas | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE (Hunter) |
| Other colorimetric indicators | Spectral reflectance; WI (ASTM E313, CIE/ISO, AATCC, Hunter, Taube-Berger-Stensby); YI (ASTM D1925, ASTM 313); metamerism index Mt; staining and colorfastness; color strength; opacity; 8° gloss; 555 hue classification; blackness (My, dM); CMYK color density (A, T, E, M); tint; color density; Munsell (some functions require PC software) |
| Standard observer | 2° / 10° |
| Illuminants | D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30), B, U35, NBF, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, LED-C2, LED-C3, LED-C5; customizable sources (41 total; some require PC software / app) |
| Display | Spectral graph / data, sample colorimetric values, color difference / graph, pass / fail result, color simulation, color bias |
| Measurement time | Approx. 1.5 seconds |
| Repeatability | Colorimetric value: MAV / SCI, ΔE*ab within 0.025 (average of 30 white-tile measurements at 5-second intervals after warm-up and calibration); spectral reflectance: MAV / SCI, standard deviation within 0.08% (within 0.18% at 400–700 nm) |
| Inter-instrument difference | MAV / SCI, ΔE*ab within 0.15 (average across 12 BCRA Series II color tiles) |
| Display resolution | 0.01 |
| Measurement method | Single measurement or average measurement (2–99 readings) |
| Positioning | Camera-assisted targeting, stabilizer positioning |
| Dimensions | L × W × H = 129 × 76 × 217 mm |
| Weight | Approx. 600 g |
| Battery | Lithium battery, 3.7 V, 5000 mAh; approx. 8,800 measurements within 8 hours |
| Illumination source service life | 10 years; more than 1.5 million measurements |
| Display screen | 3.5-inch TFT color capacitive touchscreen |
| Interfaces | USB, Bluetooth 5.0 |
| Data storage | 1,000 standards and 30,000 samples (each record can include both SCI / SCE); large-capacity app / PC storage |
| Software support | Android, iOS, Windows, WeChat Mini Program, HarmonyOS |
| Languages | Simplified Chinese, English, Traditional Chinese |
| Operating temperature | 0–40°C; 0–85% RH (non-condensing); altitude below 2,000 m |
| Storage temperature | -20–50°C; 0–85% RH (non-condensing) |
| Standard accessories | Power adapter, data cable, user manual, quality-control software (download from the official website), black/white calibration box, protective cap, wrist strap, Φ8 mm flat and pointed apertures, Φ4 mm flat and pointed apertures |
| Optional accessories | Mini printer, powder test box |