Spectrocolorimeter TS7010
TS7010 Spectrocolorimeter | Handheld Color Difference Measurement and Routine Color Quality Control
TS7010 Spectrocolorimeter is designed for quality control, R&D, and production teams that need a practical routine color inspection workflow. It supports Lab color data and ΔE color difference evaluation, incoming inspection, in-process checks, and batch-to-batch comparison.
TS7010 features a handheld design, a uniform full-spectrum LED light source, and a dual 24-array sensor. It is suited to color quality control in plastics, coatings, inks, textiles, printing, packaging, and general manufacturing. Confirm sample size, surface condition, measurement area, gloss variation, aperture, and internal QC procedures before selecting a configuration.
TS7010 Spectrocolorimeter Features
Designed for handheld measurement, routine color difference evaluation, incoming inspection, and in-process checks.
Ergonomic Handheld Design
The handheld form is designed for comfortable operation during repeated measurements, on-site inspections, incoming checks, and everyday quality control.
Uniform Full-Spectrum LED Light Source
The full-spectrum LED source provides visible-range spectral distribution for color difference comparisons, color data interpretation, and quality inspection.
Dual 24-Array Sensor
The silicon photodiode dual 24-array sensor provides a measurement basis for color data, reflectance information, and batch comparisons in entry-level QC workflows.
Calibration and Verification Documents
If your QC process requires calibration, verification, or traceability documents, confirm available services, document formats, and scope before purchase. Availability depends on the supplied version and service terms.
ETC Real-Time Calibration
TS7010 uses ETC (Every Test Calibration) technology and a standard white plate to help maintain consistent routine measurement conditions. Follow the manufacturer's instructions for the calibration procedure.
How to Choose Between TS7010 and TS7020
Both handheld spectrocolorimeters support routine color difference evaluation, incoming inspection, and in-process checks. Compare data management needs, repeatability requirements, and whether SQCX quality management software is needed.
TS7010 | Routine Color Checks and Basic QC
For basic color inspection workflows such as incoming checks, in-process inspections, master-to-sample comparison, and pass/fail decisions, consider the TS7010 Spectrocolorimeter. It is suited to workflows focused on handheld operation and routine color difference evaluation.
TS7020 | QC Software and Data Management
If you also need SQCX quality management software for data organization, color difference comparison, test report export, or supplier batch management, evaluate the TS7020 Spectrocolorimeter. Confirm software functions, export formats, and data workflows for the supplied version.
| Comparison | TS7010 | TS7020 |
|---|---|---|
| Best suited for | Routine color checks, incoming inspection, and in-process checks | Routine color checks plus QC data management and report preparation |
| Workflow | Handheld on-site inspection and basic QC implementation | Handheld inspection with a more comprehensive data management workflow |
| Light source and sensor | Uniform full-spectrum LED source and dual 24-array sensor | Uniform full-spectrum LED source and dual 24-array sensor |
| Color data | Lab color data and ΔE color difference evaluation | Lab color data and ΔE color difference evaluation |
| Repeatability focus | General routine quality control decisions | Further evaluation for workflows emphasizing data consistency and report management |
| Data management | Basic on-site decisions and routine inspection | Data organization, color difference comparison, and report export with SQCX software |
| Selection guidance | Consider when rapid implementation, basic color checks, and on-site inspection are priorities | Consider when data retention, report export, batch tracking, or supplier QC management are needed |
Selection note: This is an initial guide. If you have customer acceptance criteria, internal color tolerances, report formats, or calibration document requirements, share the sample conditions and QC workflow so the appropriate model can be confirmed.
TS7010 Frequently Asked Questions
Common questions about routine color inspection, incoming checks, in-process inspection, and implementation.
Which industries can use the TS7010?
TS7010 can be evaluated for routine color inspection in plastics, coatings, inks, textiles, printing, packaging, and general manufacturing. Typical uses include incoming inspection, in-process checks, R&D sample comparisons, and batch color difference evaluation. Confirm suitability for the sample material, surface condition, and QC workflow.
What is the difference between TS7010 and TS7020?
TS7010 is suited to routine color difference evaluation, on-site checks, and basic QC implementation. TS7020 is intended for workflows that use SQCX quality management software for data organization, color comparison, and test report export. Consider TS7020 if batch data retention, supplier acceptance records, or reports are required.
Can the TS7010 evaluate Lab and ΔE color differences?
TS7010 supports Lab color data and ΔE evaluation for master-to-sample comparison. Set acceptance criteria according to product characteristics, customer requirements, and internal QC standards; one tolerance should not be applied to every material.
Is it suitable for small or curved samples?
For small samples, restricted measurement locations, curved surfaces, or textured materials, first confirm the aperture, measurement spot size, and stable sample contact. Provide sample photos, dimensions, and the inspection objective to determine whether another aperture or positioning method is needed.
Does the TS7010 require calibration?
Color instruments generally require routine calibration or white-plate checks according to the manufacturer's procedure to maintain consistent measurement conditions. If calibration, verification, or traceability documents are required, confirm the available service, format, and scope before purchase.
What information should we provide before implementation?
Provide the sample material and dimensions, measurement area, surface gloss, texture or curvature, color difference formula, acceptance criteria, inspection frequency, and needs for report export and data retention. This helps determine whether TS7010 fits the QC workflow or whether TS7020 should also be evaluated.
Before Implementation
For samples involving multiple batches or suppliers, curved or textured surfaces, gloss variation, or small measurement areas, provide the sample conditions, inspection objective, and internal criteria before confirming the aperture, measurement method, and data workflow.
Contact Fulcrum Technology for selection adviceTS7010 Spectrocolorimeter Specifications
Use these specifications as a reference when evaluating the TS7010 for selection, purchasing, and QC implementation. The TS7010 uses D/8 geometry with a Φ8 mm platform aperture, SCI measurement, Lab color data, ΔE evaluation, and routine color quality control functions. It is suitable for incoming inspection, in-process checks, R&D comparisons, and batch color management. Confirm suitability based on sample size, surface condition, measurement area, gloss variation, and QC workflow.
| Model | TS7010 Professional Spectrocolorimeter |
|---|---|
| Measurement geometry | D/8 (diffuse illumination, 8° viewing); SCI; conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164, and DIN 5033 Teil 7 |
| Detector | Silicon photodiode array (dual 24-array) |
| Spectral system | Planar grating spectroscopic system |
| Integrating sphere diameter | Φ40 mm |
| Illumination source | Combined full-spectrum LED light source |
| Wavelength range | 400–700 nm |
| Illuminants | D65, A, F2 (CWF) |
| Resolution | 0.1 |
| Wavelength interval | Not specified |
| Reflectance measurement range | Measures reflectance at one user-specified wavelength (default: 550 nm) |
| Measurement aperture | Φ8 mm |
| Measurement mode | SCI |
| Color spaces | CIE LAB, XYZ, Yxy, LCh |
| Color difference formulas | ΔE*ab, ΔE*00 |
| Other colorimetric indices | Not specified |
| Observer angle | 10° |
| Displayed parameters | Reflectance at one user-specified wavelength (default: 550 nm), sample color values, color difference values/graph, pass/fail results, color simulation, and color bias |
| Measurement time | Approx. 1.5 seconds |
| Repeatability | Color value: MAV/SCI, ΔE*ab within 0.1 (average of 30 white-plate measurements at 5-second intervals after warm-up and calibration) |
| Inter-instrument difference | MAV/SCI, ΔE*ab within 0.4 (average of measurements on 12 BCRA Series II color tiles) |
| Measurement method | Single measurement or average measurement (2–99 readings) |
| Positioning | Stabilizing plate positioning |
| Dimensions | Length × width × height: 81 × 71 × 214 mm |
| Weight | 460 g |
| Battery | Rechargeable lithium battery |
| Light-source life | Approx. 5 years or more than 1.5 million measurements |
| Display | 3.5-inch TFT color capacitive touchscreen |
| Connectivity | Type-C USB (charging only); Bluetooth 5.0 |
| Data storage | 500 standards and 10,000 samples |
| Software support | Not specified |
| Languages | Traditional Chinese, Simplified Chinese, and English |
| Operating conditions | 0–40°C, 0–85% relative humidity (non-condensing) |
| Storage conditions | −20–50°C (non-condensing) |
| Standard accessories | Power adapter, data cable, manual, black-and-white calibration box, protective cover, wrist strap, and single Φ8 mm platform aperture |
| Optional accessories | Mini printer and powder test box |
Specification note: TS7010 is an entry-level handheld spectrocolorimeter with a single aperture, suited to Φ8 mm platform measurements, SCI mode, and routine color difference evaluation. For small, curved, or textured samples, gloss variation, SCI/SCE switching, color-card retrieval, app extensions, or CCD viewing and positioning, evaluate other models based on actual sample conditions.