MS3006 Multi-Angle Spectrophotometer
MS3006 Automotive Multi-Angle Spectrophotometer | Six-Angle Measurement for Metallic, Pearlescent and Special-Effect Finishes
MS3006 automotive multi-angle spectrophotometer The MS3006 is suited to angle-dependent color evaluation of metallic, pearlescent and special-effect finishes, automotive topcoats, plastic exterior parts and industrial coatings. It uses six illumination sources and one receiver to measure six angles and document color differences at different viewing angles.
For effect topcoats, metallic or pearlescent pigments, and specialty finishes, appearance may vary with viewing angle, lighting, surface curvature and condition. The MS3006 supports evaluation of multi-angle color difference, sparkle, color flop and diffuse coarseness. Confirm sample conditions, required angles and effect parameters, and quality-control procedures before selecting a configuration.
MS3006 Multi-Angle Spectrophotometer: Key Features
Designed for multi-angle color and effect-parameter evaluation of automotive coatings, special-effect finishes, metallic and pearlescent paints, and curved components.
Six-Angle Measurement
Six illumination sources and one receiver measure six angles, helping characterize metallic, pearlescent and special-effect colors from different viewing directions.
Multi-Angle Results Display
The touchscreen displays results at different angles for on-site review of multi-angle color differences, sample color values and pass/fail decisions.
Special-Effect Measurement
Evaluates effect parameters such as sparkle, color flop and diffuse coarseness for quality-control workflows that assess special-effect surface appearance.
256-Element Dual-Array CMOS Sensor
The 256-element dual-array CMOS image sensor provides the sensing basis for multi-angle spectral data and color analysis.
Blue-Enhanced Full-Spectrum LED
The blue-enhanced full-spectrum LED provides an illumination condition for evaluating visible-range spectral distribution and color measurements.
Concave-Grating Spectroscopy
Concave-grating spectroscopy supports spectral analysis and multi-angle color data collection for applications that track batch-to-batch color variation.
Standard White Tile and Calibration
Use the standard white tile for routine calibration and measurement-condition checks according to operating procedures. Confirm calibration frequency and method in the manufacturer’s instructions and quality-control process.
MCU and Wireless Connectivity
An industrial-grade real-time MCU supports Wi-Fi and Bluetooth 5.0. Evaluate deployment according to on-site measurement and data-management needs.
Handheld Design
The housing and measurement-button layout support handheld operation in laboratories, field inspections and exterior-part measurements.
Color-Camera Preview and Positioning
The built-in color camera helps operators confirm the measurement area, supporting fixed measurement points, curved workpieces and more consistent sample positioning.
Multiple Color Spaces and Illuminants
Supports CIE LAB, XYZ, Yxy, LCh, βxy and DIN Lab99 color spaces, along with illuminants including D65, A, C, D50, D55, D75 and the F series.
Measurement Data and Analysis
The display presents spectra and values, sample color data, color differences, pass/fail results, color simulation, and effect values and differences for on-site review and quality records.
Selection Guidance
The MS3006 is intended for six-angle color measurement and special-effect surface evaluation. For metallic or pearlescent pigments, curved components or special-effect coatings, first confirm measurement angles, effect parameters, reference-standard setup, surface condition and internal acceptance criteria against your quality-control workflow.
Contact Fulcrum Technology about MS3006 selectionMS3006 · TECHNICAL REFERENCE
MS3006 Multi-Angle Spectrophotometer Specifications
Use these specifications as a guide for product selection and application review. Configurations may vary; confirm requirements against the actual sample, application conditions, and product version.
| Specification | MS3006 |
|---|---|
| Model | MS3006 |
| Measurement Geometry | 6 measurement angles (6 illumination sources, 1 receiver) |
| Measure Angle | 45° receiver: 45as−15°, 45as15°, 45as25°, 45as45°, 45as75°, 45as110°. Standards: ASTM D 2244, E 308, E 1164, E 2194, E2539, DIN 5033, 5036, 6174, 6175-1, 6175-2, ISO 7724, 11664-4, and SAE J 1545. |
| Application | Accurate, consistent color measurement for metallic, pearlescent, and other complex special-effect coatings. |
| Light Source | Blue-enhanced full-spectrum LED |
| Lamp Life | 5 years or 3 million measurements |
| Spectrophotometric Mode | Concave grating |
| Sensor | 256-element dual-array CMOS image sensor |
| Wavelength Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Measurement Range | 0–600% |
| Semiband Width | 10 nm |
| Measuring Aperture | Illumination: Φ23 mm; measuring spot: 9 × 12 mm. Optional: illumination Φ10 mm; measuring spot: 6 × 8 mm. |
| Color Space | CIE LAB, XYZ, Yxy, LCh, βxy, DIN Lab99 |
| Color Difference Formula | ΔE*ab, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE DIN6175 |
| Other Colorimetric Index | Flop Index, Int-Em |
| Observer Angle | 2° / 10° |
| Illuminant | D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83/U30) |
| Display | Spectra and values, sample chromaticity, color difference values and graphs, pass/fail result, color simulation, sample effect value, and effect difference value |
| Measuring Time | Approx. 1 second per angle; approx. 6 seconds for all six angles (effect-color testing excluded) |
| Repeatability | Spectral reflectance: standard deviation within 0.08%. Chromaticity: ΔE*ab 0.03 (average of 30 white-tile measurements at 5-second intervals after calibration). |
| Reproducibility | ΔE* < 0.10 average on the gray BCRA tile; ΔE* < 0.25 average on the color BCRA tile set |
| Inter-instrument Error | 0.2 ΔE*00 (average on the reference Series II BCRA tile set) |
| Effect Parameters | Sparkle Grade (SG), Diffuse Coarseness (DC), and Color Variation (CV) |
| Effect Measurement | Six-angle SG and CV: 15as−45°, 15as−30°, 15as−15°, 15as15°, 15as45°, 15as80°; 15d diffuse coarseness (DC) |
| Effect Repeatability | SG short-term repeatability: 0.12% (10 standard deviations; average of 10 color-tile measurements at 10-second intervals after white calibration). DC short-term repeatability: 0.09% (10 standard deviations under the same conditions). |
| Effect Reproducibility | SG: 1.9%; DC: 1.4% (10 standard deviations; average on the reference Series II BCRA tile set) |
| Trigger Mode | Pressure-sensing trigger, button trigger, or software trigger |
| Measuring Mode | Single, average (1–99), or continuous measurement (1–99) |
| Locating Mode | Color-camera preview |
| Dimensions | 195 × 83 × 128 mm (L × W × H) |
| Weight | Approx. 1 kg |
| Power | Lithium-ion battery, 3.7 V, 3200 mAh; up to 6,000 continuous measurements within 8 hours of a full charge |
| Display Screen | 3.5-inch TFT color LCD with capacitive touchscreen |
| Interface | USB, Bluetooth 5.0 |
| Data Storage | 1,000 standards, 4,000 samples |
| Language | Simplified Chinese, Traditional Chinese, English |
| Operating Environment | 10°C to 50°C; humidity not exceeding 85%, non-condensing |
| Storage Environment | −20°C to 50°C; humidity not exceeding 85%, non-condensing |
| Calibration | Built-in white-tile parameters; external white tile, black light trap, and color tile |
| Calibration Interval | 4, 8, or 24 hours; or calibration at startup |
| Standard Accessories | Power adapter, USB cable, user guide, PC software (download from the official website), calibration board, black light trap, protective cap, wristband |
| Optional Accessory | Micro-printer |
| Notes | Technical parameters are for reference only and may vary by actual product configuration. |
Selection note: Confirm measurement angles, effect parameters, reference-standard setup, sample surface condition, included accessories, and acceptance criteria with Fulcrum Technology before purchase or deployment.