KS003 Multi-Angle Spectrophotometer (3 Angles)

The KS003 multi-angle spectrophotometer is designed to evaluate color flop in metallic and pearlescent paints, special-effect colors, automotive topcoats, plastic parts and cosmetic packaging. Its three-angle simultaneous measurement architecture measures 45as15°, 45as45° and 45as110° to record color changes at different viewing angles. Final selection should be based on coating and effect-pigment types, flat or curved samples, measurement-angle requirements, data management and quality-control workflow.

 
Product Overview

KS003 Multi-Angle Spectrophotometer | 3-Angle Measurement for Metallic, Pearlescent and Special-Effect Colors

The KS003 multi-angle spectrophotometer is designed for applications that require evaluation of color flop, including metallic and pearlescent paints, special-effect coatings, automotive topcoats, plastic parts and cosmetic packaging. Unlike a conventional single-angle colorimeter, the KS003 uses three light sources and one receiver to measure 45as15°, 45as45° and 45as110° simultaneously, helping document color changes at different viewing angles.

Metallic flakes, pearlescent pigments and other effect pigments can produce different lightness, chroma or hue at face and off-angle views depending on pigment orientation, coating conditions and surface state. The KS003 can be considered for automotive refinishing, effect coatings, plastic appearance parts and premium packaging color management. Confirm suitability according to coating type, sample curvature, gloss, angle requirements and the quality-control workflow.

Key Features

KS003 Applications and Measurement Highlights

Designed for multi-angle color evaluation of metallic, pearlescent, special-effect and other color-flop materials.

01

Simultaneous 3-angle measurement

Measures 45as15°, 45as45° and 45as110° simultaneously to build color data at three viewing angles for effect-color analysis.

02

For special-effect colors

Suitable for evaluation of metallic and pearlescent paints, special-effect coatings, automotive topcoats, plastic appearance parts and cosmetic packaging that require multi-angle color judgment.

03

Optical and sensing architecture

Uses a blue-enhanced full-spectrum LED source, concave-grating spectroscopic design and a 256-pixel dual-array CMOS image sensor as the basis for spectral measurement and multi-angle color data.

04

Color analysis functions

Supports multiple color spaces, color-difference formulas, illuminants and observer angles for comparison against industry, customer or internal QC requirements.

05

Operation and data handling

Features a color-camera preview, 3.5-inch capacitive touchscreen, single, average and continuous measurement modes, plus USB and Bluetooth connectivity for field use and data management.

06

Confirm measurement conditions before implementation

Before adopting the KS003, verify whether samples show visible color flop or contain metallic or pearlescent pigments. Also confirm measurement angles, flat or curved surfaces, gloss, standard-color setup, data-management needs and internal acceptance criteria.

Model Selection Guidance

For metallic, pearlescent, special-effect or automotive coating color management, the KS003 is an initial option to evaluate for three-angle measurement. If more angles or broader effect-color analysis are required, also consider multi-angle spectrophotometers such as the KS006, MS3006, MS3008 or MS3012. Final selection should be confirmed against sample conditions, inspection objectives and the QC workflow.

Contact Fulcrum Technology to discuss KS003 selection

 

KS003 Multi-Angle Spectrophotometer Specifications

Use these specifications as a reference for product selection, purchasing and quality-control planning. The KS003 measures three angles—45as15°, 45as45° and 45as110°—simultaneously. It is intended for multi-angle color-management applications involving metallic and pearlescent paints, special-effect colors, automotive topcoats, plastic parts and cosmetic packaging. Confirm coating type, effect pigments, sample geometry and quality requirements for each application.

ItemSpecification
Product modelKS003
Product nameMulti-Angle Spectrophotometer
SeriesKS003 Series Multi-Angle Spectrophotometer
Measurement geometry3 measurement angles (3 light sources, 1 receiver)
Color measurement angles45as15°, 45as45°, 45as110°
StandardsASTM D2244, ASTM E308, ASTM E1164, ASTM E2194, ASTM E2539, DIN 5033, DIN 5036, DIN 6174, DIN 6175-1, DIN 6175-2, ISO 7724, ISO 11664-4, SAE J1545
FeaturesMulti-angle color measurement and quality comparison for solid, metallic, pearlescent and other special-effect colors. Actual evaluation depends on the sample and internal acceptance criteria.
IlluminantBlue-enhanced full-spectrum LED
Light-source life10 years or 5 million measurements
Spectroscopic methodConcave grating
Sensor256-pixel dual-array CMOS image sensor
Wavelength range400–700 nm
Wavelength output interval10 nm
Half bandwidth10 nm
Measurement range0–600%
Measurement apertureIllumination Φ23 mm / sampling area 9 × 12 mm; optional: illumination Φ10 mm / sampling area 6 × 8 mm
Color spacesCIE LAB, XYZ, Yxy, LCh, βxy, DIN Lab99, RGB, Hunter Lab
Color-difference formulasΔE*ab, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE DIN6175, multiple automotive-brand color-difference formulas, ΔE (Hunter), ΔE*ch, ΔE*uv
Other color indicesFlop Index, color flop index, metamerism
Observer angles2° / 10°
IlluminantsD65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30), B, U35, NBF, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, LED-C2, LED-C3, LED-C5
DisplaySpectral graphs/data, sample color values, color differences/graphs, pass/fail results, color simulation
Measurement timeAbout 1 second for one angle; about 3 seconds for all angles
Spectral reflectance repeatabilityStandard deviation within 0.08%
Color-value repeatability0.02 ΔE*ab (after instrument warm-up and calibration; average of 30 white-tile measurements at 5-second intervals)
Color reproducibilityΔE < 0.10 (average for gray BCRA tiles); ΔE < 0.25 (average for colored BCRA tiles)
Inter-instrument difference0.2 ΔE*00 (average of 12 BCRA Series II tiles)
Effect parametersNot specified
Effect measurementNot specified
Effect repeatabilityNot specified
Effect reproducibilityNot specified
TriggerButton or software trigger
Measurement modesSingle, average (1–99 measurements), continuous (1–99 measurements)
PositioningColor-camera preview
Dimensions195 × 83 × 128 mm
WeightAbout 1 kg
BatteryLithium battery, 3.7 V, 5000 mAh; up to 5000 continuous measurements within 8 hours after a full charge
Display screen3.5-inch TFT true-color capacitive touchscreen
InterfacesUSB, Bluetooth
Data storage1,000 standards, 10,000 samples
LanguagesSimplified Chinese, Traditional Chinese, English, Russian
Operating environment10–50°C, humidity no more than 85% RH, non-condensing
Storage environment-20–50°C, humidity no more than 85% RH, non-condensing
CalibrationBuilt-in white-tile parameters, external white tile and black tube
Calibration interval4 hours, 8 hours, 24 hours, or at startup
Standard accessoriesPower adapter, data cable, manual, quality-management software (download from the official website), calibration case, black tube, protective cover, wrist strap
Optional accessoryMini printer
IndustriesAutomotive, plastics, coatings, textiles and dyeing, food, cosmetics, building materials
ApplicationsMetallic paints, pearlescent paints, special-effect colors, multi-angle color-difference management and quality control

Selection note: The KS003 is intended for metallic, pearlescent and special-effect applications that require three-angle measurement. For samples with pronounced color flop or differences caused by metallic-flake orientation or pearlescent effects, provide sample details, measurement angles, surface gloss, standard-color setup and data workflow for review. Confirm supplied configuration, custom apertures, software functions and accessories with Fulcrum Technology.

top