YS4560 45/0 Spectrophotometer for Automotive Coatings

Product OverviewYS4560 45/0 Spectrophotometer | Color Quality Control for Automotive CoatingsThe 3nh YS4560 45/0 spectrophotometer is designed for objective color evaluation and quality control across automotive coatings, plastic parts, paints, inks, printing, packaging, and general manufacturing. Its 45°/0° measurement geometry supports consistent surface color comparison and color-data collection.Use the YS4560 to support Lab data collection and ΔE color-difference evaluation in incoming inspection, in-process checks, batch comparison, and shipment acceptance. Metallic, pearlescent, and special-effect finishes may change appearance with viewing angle; evaluate whether a multi-angle instrument is better suited to those samples. Confirm selection according to material, gloss, texture, measurement area, coating type, and quality-control workflow.Key FeaturesYS4560 45/0 Spectrophotometer ApplicationsFor objective color assessment across coatings and manufactured surfaces where a 45°/0° measurement geometry is appropriate.0145°/0° Measurement GeometryProvides a defined measurement geometry for objective surface-color comparison. Verify that it matches the sample and inspection method.02Broad Material ApplicationsSuitable for evaluating automotive coatings, plastic parts, paints, inks, printed materials, packaging, and products in general manufacturing.03Lab Data and ΔE AssessmentSupports Lab color-data collection and color-difference evaluation to help compare samples against references and applicable tolerances.04Quality Checks Across ProductionUse color measurements for incoming inspection, in-process checks, batch comparison, and shipment acceptance as part of a defined quality workflow.05Practical Surface Color ComparisonCompare paints, coatings, plastics, and printed or packaged surfaces while accounting for material, gloss, texture, and measurement area.06Review Angle-Sensitive Finishes Before SelectionMetallic, pearlescent, and special-effect finishes can change appearance with viewing angle. If this behavior is important to the inspection, assess whether a multi-angle spectrophotometer is required.Selection GuidanceBefore choosing an instrument, confirm the sample material, gloss, texture, measurement area, coating type, inspection purpose, and quality-control workflow. For finishes with pronounced angle-dependent color changes, compare the 45°/0° approach with a multi-angle solution. Contact Fulcrum Technology to discuss the application and suitable configuration.Contact Fulcrum Technology for product selection advice#ys4560-product-detail-2026 { color:#27384a; font-size:15px; line-height:1.7; }#ys4560-product-detail-2026 * { box-sizing:border-box; }#ys4560-product-detail-2026 p { margin:0; }#ys4560-product-detail-2026 a { color:#b34238; font-weight:800; text-decoration:none; }#ys4560-product-detail-2026 a:hover { color:#8f2f28; text-decoration:underline; }#ys4560-product-detail-2026 .product-intro-section { margin-bottom:18px; padding:22px; border:1px solid #dce7ef; border-radius:18px; background:linear-gradient(135deg,#ffffff 0%,#f7fbfe 100%); box-shadow:0 8px 22px rgba(39,72,98,.06); }#ys4560-product-detail-2026 .intro-label,#ys4560-product-detail-2026 .section-pill { display:inline-block; margin-bottom:8px; padding:5px 13px; color:#b34238; background:#fff1ef; border:1px solid #f3d6d2; border-radius:999px; font-size:13px; line-height:1.4; font-weight:800; letter-spacing:.04em; }#ys4560-product-detail-2026 .product-intro-section h2,#ys4560-product-detail-2026 .section-heading h2 { margin:0 0 10px; color:#1e3448; font-size:25px; line-height:1.35; font-weight:800; }#ys4560-product-detail-2026 .product-intro-section p,#ys4560-product-detail-2026 .section-heading p { color:#526678; font-size:15px; line-height:1.8; }#ys4560-product-detail-2026 .product-intro-section p+p { margin-top:9px; }#ys4560-product-detail-2026 .section-heading { margin-bottom:16px; text-align:center; }#ys4560-product-detail-2026 .feature-grid { display:grid; grid-template-columns:repeat(3,1fr); gap:12px; }#ys4560-product-detail-2026 .feature-card { overflow:hidden; border:1px solid #dce7ef; border-radius:16px; background:#fff; box-shadow:0 6px 16px rgba(39,72,98,.04); }#ys4560-product-detail-2026 .feature-content { padding:15px; }#ys4560-product-detail-2026 .feature-content span { display:inline-block; margin-bottom:7px; color:#b34238; font-size:12px; line-height:1; font-weight:900; letter-spacing:.08em; }#ys4560-product-detail-2026 .feature-content h3 { margin:0 0 7px; color:#1e3448; font-size:17px; line-height:1.35; font-weight:800; }#ys4560-product-detail-2026 .feature-content p { color:#526678; font-size:13.5px; line-height:1.65; }#ys4560-product-detail-2026 .feature-card-wide { grid-column:span 3; }#ys4560-product-detail-2026 .guide-note { margin-top:18px; padding:16px; border:1px solid #f0dfc1; border-radius:16px; background:#fffaf2; }#ys4560-product-detail-2026 .guide-note h3 { margin:0 0 7px; color:#5b4a32; font-size:18px; line-height:1.4; font-weight:800; }#ys4560-product-detail-2026 .guide-note p { color:#5b4a32; font-size:14px; line-height:1.7; }#ys4560-product-detail-2026 .guide-note a { display:inline-block; margin-top:10px; padding:8px 14px; color:#fff; background:#b34238; border:1px solid #b34238; border-radius:999px; font-size:13px; line-height:1.4; font-weight:800; }#ys4560-product-detail-2026 .guide-note a:hover { opacity:.92; text-decoration:none; }@media(max-width:991px){#ys4560-product-detail-2026 .feature-grid{grid-template-columns:repeat(2,1fr)}#ys4560-product-detail-2026 .feature-card-wide{grid-column:span 2}}@media(max-width:767px){#ys4560-product-detail-2026 .product-intro-section{padding:18px}#ys4560-product-detail-2026 .product-intro-section h2,#ys4560-product-detail-2026 .section-heading h2{font-size:22px}#ys4560-product-detail-2026 .feature-grid{grid-template-columns:1fr;gap:12px}#ys4560-product-detail-2026 .feature-card-wide{grid-column:span 1}#ys4560-product-detail-2026 .feature-content h3{font-size:16px}#ys4560-product-detail-2026 .feature-content p{font-size:13.5px}}429 container

Product Overview

YS4560 45/0 Spectrophotometer | Color Quality Control for Automotive Coatings

The 3nh YS4560 45/0 spectrophotometer is designed for objective color evaluation and quality control across automotive coatings, plastic parts, paints, inks, printing, packaging, and general manufacturing. Its 45°/0° measurement geometry supports consistent surface color comparison and color-data collection.

Use the YS4560 to support Lab data collection and ΔE color-difference evaluation in incoming inspection, in-process checks, batch comparison, and shipment acceptance. Metallic, pearlescent, and special-effect finishes may change appearance with viewing angle; evaluate whether a multi-angle instrument is better suited to those samples. Confirm selection according to material, gloss, texture, measurement area, coating type, and quality-control workflow.

Key Features

YS4560 45/0 Spectrophotometer Applications

For objective color assessment across coatings and manufactured surfaces where a 45°/0° measurement geometry is appropriate.

01

45°/0° Measurement Geometry

Provides a defined measurement geometry for objective surface-color comparison. Verify that it matches the sample and inspection method.

02

Broad Material Applications

Suitable for evaluating automotive coatings, plastic parts, paints, inks, printed materials, packaging, and products in general manufacturing.

03

Lab Data and ΔE Assessment

Supports Lab color-data collection and color-difference evaluation to help compare samples against references and applicable tolerances.

04

Quality Checks Across Production

Use color measurements for incoming inspection, in-process checks, batch comparison, and shipment acceptance as part of a defined quality workflow.

05

Practical Surface Color Comparison

Compare paints, coatings, plastics, and printed or packaged surfaces while accounting for material, gloss, texture, and measurement area.

06

Review Angle-Sensitive Finishes Before Selection

Metallic, pearlescent, and special-effect finishes can change appearance with viewing angle. If this behavior is important to the inspection, assess whether a multi-angle spectrophotometer is required.

Selection Guidance

Before choosing an instrument, confirm the sample material, gloss, texture, measurement area, coating type, inspection purpose, and quality-control workflow. For finishes with pronounced angle-dependent color changes, compare the 45°/0° approach with a multi-angle solution. Contact Fulcrum Technology to discuss the application and suitable configuration.

Contact Fulcrum Technology for product selection advice

429 container


Specification

YS4560 45/0 Spectrophotometer Specifications

Use these specifications as a reference when evaluating the YS4560 45/0 spectrophotometer for selection, purchasing, and quality-control setup. The YS4560 uses 45°/0° measurement geometry for color inspection of automotive coatings, plastic parts, paints and inks, textiles, printing, ceramics, traffic signs, and reflective materials. Confirm the configuration based on sample material, gloss, texture, measurement area, inspection standards, and your quality-control workflow.

ModelYS4560
Illumination geometry45/0 (uniform 45° circumferential illumination, 0° viewing); complies with CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724-1, ASTM E1164, and DIN 5033 Part 7
FeaturesHigh-accuracy spectrophotometer for precise color analysis and communication in laboratories. Suitable for color measurement and quality control of plastics and electronics, paints and inks, textiles and dyeing, printing, and ceramics; supports fluorescent samples. Measures luminance factor and chromaticity coordinates of traffic signs, road markings, and reflective films. Includes standard colors for GB 2893 and GB/T 18833 and supports manually defined polygon or rectangular tolerances.
Integrating sphere sizeΦ48 mm
Light sourceCombined LED light source and UV light source
Spectral separationConcave grating
SensorDual-array 256-pixel CMOS image sensor
Wavelength range400–700 nm
Wavelength interval10 nm
Bandwidth10 nm
Reflectance range0–200%
Measurement aperturesTwo aperture options: MAV Φ8 mm/Φ10 mm; SAV Φ4 mm/Φ5 mm
Color spacesCIE LAB, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, βxy
Color difference formulasΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, ΔE (Hunter)
Other color indicesWI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM E313), metamerism index MI, staining fastness, color-change fastness, color strength, opacity, and polygon color tolerance
Observer angle2°/10°
IlluminantsD65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83/U30)
DisplaySpectral graph and data, sample color values, color-difference values and graphs, pass/fail results, and color trends
Measurement timeApprox. 1.5 seconds
RepeatabilityMAV spectral reflectance: standard deviation no greater than 0.08%; MAV color value: ΔE*ab no greater than 0.03 (after warm-up and calibration, averaged over 30 white-board measurements at 5-second intervals)
Inter-instrument differenceMAV, ΔE*ab no greater than 0.15 (BCRA Series II, average of 12 color-tile measurements)
Measurement modeSingle measurement or average measurement (2–99 readings)
DimensionsLength × width × height = 184 × 77 × 105 mm
WeightApprox. 600 g
Battery capacityLithium battery; up to 5,000 measurements or 8 hours
Light source lifetime5 years or more than 3 million measurements
Display screen3.5-inch color TFT capacitive touchscreen
InterfaceDual-mode USB and Bluetooth® 4.0 (compatible with 2.1)
Data storage1,000 standard samples and 30,000 test samples
LanguagesTraditional Chinese, Simplified Chinese, and English
Operating temperature0–40°C; relative humidity 0–85% (non-condensing); altitude below 2,000 m
Storage temperature-20–50°C; relative humidity 0–85% (non-condensing)
Standard accessoriesPower adapter, data cable, built-in lithium battery, user manual, quality-control software (download from the official website), black/white calibration box, and protective cover
Optional accessoriesMini printer, powder test box, and multifunctional test component
NoteSpecifications are for reference only. The product supplied shall be considered final.

Selection note: The YS4560 is suited to 45°/0° surface color measurement, Lab data collection, ΔE evaluation, and color assessment of traffic signs and reflective materials. For metallic, pearlescent, or special-effect coatings with visible angle-dependent color changes, consider whether a multi-angle spectrophotometer is needed. Confirm final supply contents, software functions, accessories, and measurement conditions with Fulcrum Technology.