MS3012 Twelve-Angle Multi-Angle Spectrophotometer
MS3012 Automotive Multi-Angle Spectrophotometer | 12-Angle Measurement for Metallic, Pearlescent and Special-Effect Finishes
MS3012 automotive multi-angle spectrophotometer is designed for applications that require multi-angle appearance evaluation, including metallic, pearlescent and special-effect colors, automotive topcoats, plastic parts and industrial coatings. The MS3012 uses seven light sources and two receivers to measure at 12 angles, helping document color differences under different viewing geometries.
For effect topcoats, metallic or pearlescent pigments, and other special finishes, appearance can vary with viewing angle, lighting, surface curvature and condition. The MS3012 supports evaluation of multi-angle color difference, sparkle, color travel and graininess. Confirm the model against the sample, required angles, effect parameters and quality-control workflow.
MS3012 Multi-Angle Spectrophotometer Features
Designed for multi-angle color and effect-parameter evaluation of automotive coatings, special-effect colors, metallic and pearlescent finishes, and curved parts.
12-Angle Measurement
Seven light sources and two receivers provide 12 measurement angles to build color data for metallic, pearlescent and special-effect finishes across viewing geometries.
Multi-Angle Results Display
The touchscreen displays results by angle, making multi-angle color differences, sample colorimetric values and evaluation results easy to review on site.
Effect-Parameter Evaluation
Evaluate effect parameters such as sparkle, color travel and graininess for quality-control workflows that assess appearance differences in special-effect finishes.
256-Pixel Dual-Array CMOS Sensor
A 256-pixel dual-array CMOS image sensor provides the sensing foundation for multi-angle spectral data capture and color analysis.
Blue-Enhanced Full-Spectrum LED
The blue-enhanced full-spectrum LED provides an illumination condition for evaluating visible-range spectral distribution and color measurement.
Concave-Grating Spectral Technology
Concave-grating technology supports spectral-data analysis and multi-angle color-data creation for applications that track batch-to-batch color variation.
White-Standard and Calibration
Use the white standard for routine calibration and measurement-condition checks according to the operating procedure. Confirm calibration frequency and method with the manufacturer’s instructions and quality-control process.
MCU and Wireless Connectivity
An industrial-grade real-time MCU supports Wi-Fi and Bluetooth 5.0. Select an implementation approach based on on-site measurement and data-management needs.
Handheld Operation
The body shape and measurement-button layout are designed for handheld use in laboratories, field inspections and appearance-part measurements.
Color-Camera Preview Positioning
The built-in color camera helps operators confirm the measurement area, supporting fixed measurement points, curved workpieces and samples that require consistent positioning.
Multiple Color Spaces and Illuminants
Supports color spaces including CIE LAB, XYZ, Yxy, LCh, βxy and DIN Lab99, along with illuminants such as D65, A, C, D50, D55, D75 and the F series.
Measurement Data Display and Analysis
The screen displays spectral graphs and data, sample colorimetric values, color differences, pass/fail results, color simulation, sample effect values and effect differences for on-site review and quality records.
What to Confirm Before Selection
The MS3012 is suited to 12-angle color measurement and special-effect surface evaluation. For metallic or pearlescent pigments, curved parts or special-effect coatings, first confirm the required angles, effect parameters, standard-color setup, sample-surface condition and internal acceptance criteria, then assess fit with your quality-control process.
Contact Fulcrum Technology to Discuss MS3012 SelectionMS3012 Automotive Multi-Angle Spectrophotometer Specifications
Use these specifications as a reference when evaluating the MS3012 multi-angle spectrophotometer for selection, purchasing and quality-control deployment. Its 12 measurement angles support color measurement for metallic, pearlescent and special-effect colors, automotive topcoats, plastic parts and industrial coatings. Confirm model suitability based on the sample, effect pigments, surface gloss, required angles and effect parameters, and your quality-control workflow.
| Model | MS3012 Series |
|---|---|
| Measurement geometry | 12 measurement angles (7 light sources, 2 receivers) |
| Color measurement angles | 45° receiver: 45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, 45as110°; 15° receiver: 15as-45°, 15as-15°, 15as15°, 15as-30°, 15as45°, 15as80° |
| Standards | ASTM D2244, ASTM E308, ASTM E1164, ASTM E2194, ASTM E2539, DIN 5033, DIN 5036, DIN 6174, DIN 6175-1, DIN 6175-2, ISO 7724, ISO 11664-4, SAE J1545 |
| Features | For multi-angle color measurement and quality comparison of metallic, pearlescent and other complex special-effect colors. Confirm evaluations against the sample, standard-color setup and internal acceptance criteria. |
| Illumination source | Blue-enhanced white full-spectrum LED |
| Illumination source life | 5 years or 3 million measurements |
| Spectral system | Concave grating |
| Detector | 256-pixel dual-array CMOS image sensor |
| Wavelength range | 400–700 nm |
| Wavelength interval | 10 nm |
| Measurement range | 0–600% |
| Half bandwidth | 10 nm |
| Measurement aperture | Illumination Φ23 mm / sampling 9 × 12 mm; custom option: illumination Φ10 mm / sampling 6 × 8 mm |
| Color spaces | CIE LAB, XYZ, Yxy, LCh, βxy, DIN Lab99 |
| Color difference formulas | ΔE*ab, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE DIN6175, and color-difference formulas for multiple automotive brands |
| Other colorimetric indices | Flop Index, radiance value |
| Observer angles | 2° / 10° |
| Illuminants | D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30) |
| Display | Spectral graph / data, sample colorimetric values, color difference / graph, pass / fail results, color simulation, sample effect value and effect difference |
| Measurement time | Approximately 1 second per angle and 6 seconds for all angles (excluding special-effect color testing) |
| Color repeatability | Spectral reflectance: standard deviation within 0.08%; colorimetric value: 0.02 ΔE*ab (mean of 30 white-tile measurements at 5-second intervals after instrument warm-up and calibration) |
| Color reproducibility | ΔE* < 0.10 (mean of gray BCRA tiles); ΔE* < 0.25 (mean of colored BCRA tiles) |
| Inter-instrument difference | 0.18 ΔE*00 (mean of measurements on 12 BCRA Series II tiles) |
| Effect parameters | Sparkle, color travel and graininess |
| Effect measurement | Six-angle sparkle and color-travel data: 15as-45°, 15as-30°, 15as-15°, 15as15°, 15as45°, 15as80°; 15d diffuse graininess |
| Effect repeatability | Short-term sparkle repeatability: 0.12% (10-measurement standard deviation; mean of 10 color-tile measurements at 10-second intervals after warm-up and calibration); short-term graininess repeatability: 0.09% (same method) |
| Effect reproducibility | Sparkle reproducibility: 1.9% (10-measurement standard deviation; mean of 12 BCRA Series II tiles); graininess reproducibility: 1.4% (same method) |
| Trigger methods | Pressure-sensing trigger, button trigger and software trigger |
| Measurement modes | Single, average (1–99 measurements) and continuous (1–99 measurements) |
| Positioning | CCD color preview |
| Dimensions | 195 × 83 × 128 mm (L × W × H) |
| Weight | Approx. 1 kg |
| Battery | Lithium battery, 3.7 V, 3200 mAh; up to 6,000 continuous tests within 8 hours on a full charge |
| Display screen | 3.5-inch full-color TFT capacitive touchscreen |
| Interfaces | USB, Bluetooth 5.0 |
| Data storage | 1,000 standards and 4,000 samples |
| Languages | Simplified Chinese, Traditional Chinese and English |
| Operating temperature | 10–50°C; humidity ≤85%, non-condensing |
| Storage temperature | -20–50°C; humidity ≤85%, non-condensing |
| Calibration | Built-in white-tile parameters; external white tile, black trap and color tiles |
| Calibration intervals | 4 hours, 8 hours, 24 hours and calibration at startup |
| Standard accessories | Power adapter, data cable, manual, quality-management software (website download), calibration case, black trap, protective cover and wrist strap |
| Optional accessories | Mini printer |
| Note | Technical specifications are for reference only; actual products supplied prevail. |
Selection note: The MS3012 is intended for 12-angle color measurement and evaluation of special-effect surfaces, including sparkle, color travel and graininess. For metallic or pearlescent pigments, curved parts or special-effect coatings, confirm the required angles, effect parameters, standard-color setup, sample-surface condition and internal acceptance criteria before assessing fit with your quality-control workflow. Verify supplied items, software functions, accessories and measurement conditions with Fulcrum Technology.