MS3012 Twelve-Angle Multi-Angle Spectrophotometer

The MS3012 automotive multi-angle spectrophotometer is suitable for color quality-control applications involving metallic, pearlescent and special-effect colors, automotive topcoats, plastic exterior parts, industrial coatings, and evaluation of color travel. Compared with a conventional single-angle instrument, it records differences in lightness, chroma, hue, and appearance effects at different viewing angles, supporting multi-angle color data for formulation development, incoming inspection, process monitoring, batch comparison, and shipment acceptance. The MS3012 uses 7 light sources and 2 receivers for 12-angle measurement and supports evaluation of Sparkle Grade (SG), Diffuse Coarseness (DC), and Color Variation (CV) on curved as well as flat surfaces. Confirm the setup according to coating type, effect pigments, sample geometry, surface gloss, required measurement angles and effect parameters, and quality-control workflow.

Product Overview

MS3012 Automotive Multi-Angle Spectrophotometer | 12-Angle Measurement for Metallic, Pearlescent and Special-Effect Finishes

MS3012 automotive multi-angle spectrophotometer is designed for applications that require multi-angle appearance evaluation, including metallic, pearlescent and special-effect colors, automotive topcoats, plastic parts and industrial coatings. The MS3012 uses seven light sources and two receivers to measure at 12 angles, helping document color differences under different viewing geometries.

For effect topcoats, metallic or pearlescent pigments, and other special finishes, appearance can vary with viewing angle, lighting, surface curvature and condition. The MS3012 supports evaluation of multi-angle color difference, sparkle, color travel and graininess. Confirm the model against the sample, required angles, effect parameters and quality-control workflow.

Key Features

MS3012 Multi-Angle Spectrophotometer Features

Designed for multi-angle color and effect-parameter evaluation of automotive coatings, special-effect colors, metallic and pearlescent finishes, and curved parts.

MS3012 12-angle measurement illustration
01

12-Angle Measurement

Seven light sources and two receivers provide 12 measurement angles to build color data for metallic, pearlescent and special-effect finishes across viewing geometries.

MS3012 multi-angle spectrophotometer touchscreen displaying measurement results
02

Multi-Angle Results Display

The touchscreen displays results by angle, making multi-angle color differences, sample colorimetric values and evaluation results easy to review on site.

MS3012 multi-angle spectrophotometer measuring sparkle, color travel and graininess
03

Effect-Parameter Evaluation

Evaluate effect parameters such as sparkle, color travel and graininess for quality-control workflows that assess appearance differences in special-effect finishes.

MS3012 256-pixel dual-array CMOS image sensor
04

256-Pixel Dual-Array CMOS Sensor

A 256-pixel dual-array CMOS image sensor provides the sensing foundation for multi-angle spectral data capture and color analysis.

MS3012 Blue-Enhanced Full-Spectrum LED
05

Blue-Enhanced Full-Spectrum LED

The blue-enhanced full-spectrum LED provides an illumination condition for evaluating visible-range spectral distribution and color measurement.

MS3012 Concave-Grating Spectral Technology
06

Concave-Grating Spectral Technology

Concave-grating technology supports spectral-data analysis and multi-angle color-data creation for applications that track batch-to-batch color variation.

MS3012 multi-angle spectrophotometer white standard
07

White-Standard and Calibration

Use the white standard for routine calibration and measurement-condition checks according to the operating procedure. Confirm calibration frequency and method with the manufacturer’s instructions and quality-control process.

MS3012 industrial-grade MCU supporting Wi-Fi and Bluetooth 5.0
08

MCU and Wireless Connectivity

An industrial-grade real-time MCU supports Wi-Fi and Bluetooth 5.0. Select an implementation approach based on on-site measurement and data-management needs.

MS3012 multi-angle spectrophotometer ergonomic design
09

Handheld Operation

The body shape and measurement-button layout are designed for handheld use in laboratories, field inspections and appearance-part measurements.

MS3012 color-camera preview of the measurement area
10

Color-Camera Preview Positioning

The built-in color camera helps operators confirm the measurement area, supporting fixed measurement points, curved workpieces and samples that require consistent positioning.

MS3012 supported color spaces and illuminants
11

Multiple Color Spaces and Illuminants

Supports color spaces including CIE LAB, XYZ, Yxy, LCh, βxy and DIN Lab99, along with illuminants such as D65, A, C, D50, D55, D75 and the F series.

MS3012 multi-angle spectrophotometer data analysis and results display
12

Measurement Data Display and Analysis

The screen displays spectral graphs and data, sample colorimetric values, color differences, pass/fail results, color simulation, sample effect values and effect differences for on-site review and quality records.

What to Confirm Before Selection

The MS3012 is suited to 12-angle color measurement and special-effect surface evaluation. For metallic or pearlescent pigments, curved parts or special-effect coatings, first confirm the required angles, effect parameters, standard-color setup, sample-surface condition and internal acceptance criteria, then assess fit with your quality-control process.

Contact Fulcrum Technology to Discuss MS3012 Selection

Specification

MS3012 Automotive Multi-Angle Spectrophotometer Specifications

Use these specifications as a reference when evaluating the MS3012 multi-angle spectrophotometer for selection, purchasing and quality-control deployment. Its 12 measurement angles support color measurement for metallic, pearlescent and special-effect colors, automotive topcoats, plastic parts and industrial coatings. Confirm model suitability based on the sample, effect pigments, surface gloss, required angles and effect parameters, and your quality-control workflow.

ModelMS3012 Series
Measurement geometry12 measurement angles (7 light sources, 2 receivers)
Color measurement angles45° receiver: 45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, 45as110°; 15° receiver: 15as-45°, 15as-15°, 15as15°, 15as-30°, 15as45°, 15as80°
StandardsASTM D2244, ASTM E308, ASTM E1164, ASTM E2194, ASTM E2539, DIN 5033, DIN 5036, DIN 6174, DIN 6175-1, DIN 6175-2, ISO 7724, ISO 11664-4, SAE J1545
FeaturesFor multi-angle color measurement and quality comparison of metallic, pearlescent and other complex special-effect colors. Confirm evaluations against the sample, standard-color setup and internal acceptance criteria.
Illumination sourceBlue-enhanced white full-spectrum LED
Illumination source life5 years or 3 million measurements
Spectral systemConcave grating
Detector256-pixel dual-array CMOS image sensor
Wavelength range400–700 nm
Wavelength interval10 nm
Measurement range0–600%
Half bandwidth10 nm
Measurement apertureIllumination Φ23 mm / sampling 9 × 12 mm; custom option: illumination Φ10 mm / sampling 6 × 8 mm
Color spacesCIE LAB, XYZ, Yxy, LCh, βxy, DIN Lab99
Color difference formulasΔE*ab, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE DIN6175, and color-difference formulas for multiple automotive brands
Other colorimetric indicesFlop Index, radiance value
Observer angles2° / 10°
IlluminantsD65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30)
DisplaySpectral graph / data, sample colorimetric values, color difference / graph, pass / fail results, color simulation, sample effect value and effect difference
Measurement timeApproximately 1 second per angle and 6 seconds for all angles (excluding special-effect color testing)
Color repeatabilitySpectral reflectance: standard deviation within 0.08%; colorimetric value: 0.02 ΔE*ab (mean of 30 white-tile measurements at 5-second intervals after instrument warm-up and calibration)
Color reproducibilityΔE* < 0.10 (mean of gray BCRA tiles); ΔE* < 0.25 (mean of colored BCRA tiles)
Inter-instrument difference0.18 ΔE*00 (mean of measurements on 12 BCRA Series II tiles)
Effect parametersSparkle, color travel and graininess
Effect measurementSix-angle sparkle and color-travel data: 15as-45°, 15as-30°, 15as-15°, 15as15°, 15as45°, 15as80°; 15d diffuse graininess
Effect repeatabilityShort-term sparkle repeatability: 0.12% (10-measurement standard deviation; mean of 10 color-tile measurements at 10-second intervals after warm-up and calibration); short-term graininess repeatability: 0.09% (same method)
Effect reproducibilitySparkle reproducibility: 1.9% (10-measurement standard deviation; mean of 12 BCRA Series II tiles); graininess reproducibility: 1.4% (same method)
Trigger methodsPressure-sensing trigger, button trigger and software trigger
Measurement modesSingle, average (1–99 measurements) and continuous (1–99 measurements)
PositioningCCD color preview
Dimensions195 × 83 × 128 mm (L × W × H)
WeightApprox. 1 kg
BatteryLithium battery, 3.7 V, 3200 mAh; up to 6,000 continuous tests within 8 hours on a full charge
Display screen3.5-inch full-color TFT capacitive touchscreen
InterfacesUSB, Bluetooth 5.0
Data storage1,000 standards and 4,000 samples
LanguagesSimplified Chinese, Traditional Chinese and English
Operating temperature10–50°C; humidity ≤85%, non-condensing
Storage temperature-20–50°C; humidity ≤85%, non-condensing
CalibrationBuilt-in white-tile parameters; external white tile, black trap and color tiles
Calibration intervals4 hours, 8 hours, 24 hours and calibration at startup
Standard accessoriesPower adapter, data cable, manual, quality-management software (website download), calibration case, black trap, protective cover and wrist strap
Optional accessoriesMini printer
NoteTechnical specifications are for reference only; actual products supplied prevail.

Selection note: The MS3012 is intended for 12-angle color measurement and evaluation of special-effect surfaces, including sparkle, color travel and graininess. For metallic or pearlescent pigments, curved parts or special-effect coatings, confirm the required angles, effect parameters, standard-color setup, sample-surface condition and internal acceptance criteria before assessing fit with your quality-control workflow. Verify supplied items, software functions, accessories and measurement conditions with Fulcrum Technology.

top