KS012 Multi-Angle Spectrophotometer (12 Angles)
KS012 Multi-Angle Spectrophotometer | 12-Angle Color Evaluation for Special-Effect Materials
The KS012 multi-angle spectrophotometer is designed to evaluate color appearance that changes with viewing angle across coatings and materials. It is suited to metallic, pearlescent, solid, and special-effect colors, automotive topcoats, plastic appearance parts, cosmetic packaging, and industrial coatings.
Multi-angle measurement records color at twelve viewing angles, helping teams assess changes in lightness, chroma, and hue as the viewing direction changes. This can support R&D color matching, incoming inspection, process monitoring, batch comparison, and shipment acceptance. Confirm suitability according to coating type, effect pigments, sample geometry, surface gloss, required angles, data management, and quality-control procedures.
KS012 Multi-Angle Spectrophotometer Applications
Designed for color evaluation of materials whose appearance varies with viewing angle, including coatings and special-effect colors.
12-Angle Color Assessment
Collect multi-angle color data to document appearance changes across viewing directions and support evaluation of gonioapparent materials.
For Metallic and Pearlescent Coatings
Evaluate metallic flakes, pearlescent pigments, solid colors, and other special-effect finishes across face, side, and highlight views.
Document Appearance Changes by Angle
Review changes in lightness, chroma, and hue as viewing direction changes to build a more complete color record.
Assess Flat and Curved Parts
Consider the instrument for automotive topcoats, plastic appearance parts, cosmetic packaging, and industrial coatings; confirm sample geometry and surface condition for the intended measurement.
Support Color Matching and Quality Control
Use multi-angle records to support R&D color matching, incoming inspection, process monitoring, batch comparison, and shipment acceptance workflows.
Confirm Measurement Conditions Before Adoption
Review coating type, effect pigments, flat or curved sample geometry, surface gloss, required measurement angles, data management, reference standards, and internal acceptance criteria before selecting the instrument.
Selection Guidance
For applications that need broader multi-angle color analysis, consider the KS012 alongside the KS006 and KS003. Select a model based on the number of measurement angles required, sample conditions, inspection objectives, and quality-control workflow. Confirm detailed specifications and suitability with Fulcrum Technology before adoption.
Contact Fulcrum Technology to discuss KS012 selection429 container
KS012 Multi-Angle Spectrophotometer Specifications
The specifications below are provided as a reference for product selection, procurement, and quality-control implementation. The KS012 uses 12 measurement angles for metallic, pearlescent, special-effect, automotive exterior, plastic-part, cosmetic-packaging, and special-effect surface applications. Confirm suitability based on flat or curved sample geometry, surface gloss, effect pigments, required effect parameters, data management, and quality-control workflow.
| Product Model | KS012 |
|---|---|
| Product Name | Multi-Angle Spectrophotometer |
| Series | KS012 Series Multi-Angle Spectrophotometer |
| Measurement Geometry | 12 measurement angles (7 measurement light sources + 1 camera illumination source, 2 receivers) |
| Color Measurement Angles | 45° receiver: 45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, 45as110°; 15° receiver: 15as-45°, 15as-15°, 15as15°, 15as-30°, 15as45°, 15as80° |
| Standards | ASTM D2244, ASTM E308, ASTM E1164, ASTM E2194, ASTM E2539, DIN 5033, DIN 5036, DIN 6174, DIN 6175-1, DIN 6175-2, ISO 7724, ISO 11664-4, SAE J1545 |
| Product Features | Multi-angle color measurement and quality-control comparison for solid, metallic, pearlescent, and other complex special-effect colors. Actual evaluation depends on sample conditions, reference-standard setup, and internal acceptance criteria. |
| Illumination Source | Blue-enhanced full-spectrum LED |
| Light Source Lifetime | 10 years or 5 million measurements |
| Spectral Dispersion | Concave grating |
| Sensor | 256-pixel dual-array CMOS image sensor |
| Measurement Wavelength Range | 400–700 nm |
| Wavelength Output Interval | 10 nm |
| Half-Bandwidth | 10 nm |
| Measurement Range | 0–600% |
| Measurement Aperture | Illumination Φ23 mm / sample area 9 × 12 mm; optional customization: illumination Φ10 mm / sample area 6 × 8 mm |
| Color Spaces | CIE LAB, XYZ, Yxy, LCh, βxy, DIN Lab99, RGB, Hunter Lab |
| Color-Difference Formulas | ΔE*ab, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE DIN6175, multiple automotive-brand formulas, ΔE (Hunter), ΔE*ch, ΔE*uv |
| Other Color Metrics | Flop Index, goniochromatic index, metamerism |
| Observer Angles | 2° / 10° |
| Illuminants | D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30), B, U35, NBF, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, LED-C2, LED-C3, LED-C5 |
| Display Content | Spectral graphs / data, sample color values, color-difference values / graphs, pass / fail results, color simulation, sample effect values, effect differences |
| Measurement Time | Approximately 1 second per angle; approximately 12 seconds for all angles |
| Spectral Reflectance Repeatability | Standard deviation within 0.08% |
| Colorimetric Repeatability | 0.02 ΔE*ab (average of 30 white-tile measurements at 5-second intervals after instrument warm-up and calibration) |
| Color Reproducibility | ΔE < 0.10 (average of gray BCRA tiles); ΔE < 0.25 (average of color BCRA tiles) |
| Inter-Instrument Difference | 0.18 ΔE*00 (average across 12 BCRA Series II color tiles) |
| Effect Parameters | Sparkle, graininess, and color travel |
| Effect Measurement | Six-angle sparkle and color-travel measurement: 15as-45°, 15as-30°, 15as-15°, 15as15°, 15as45°, 15as80°; 15d diffuse graininess |
| Effect Repeatability | Short-term sparkle repeatability: 0.11% (standard deviation over 10 measurements); short-term graininess repeatability: 0.08% (standard deviation over 10 measurements) |
| Effect Reproducibility | Sparkle reproducibility: 1.8% (standard deviation over 10 measurements); graininess reproducibility: 1.3% (standard deviation over 10 measurements) |
| Triggering | Button trigger, software trigger |
| Measurement Modes | Single measurement, average measurement (1–99 times), continuous measurement (1–99 times) |
| Positioning | Color camera preview |
| Dimensions | 195 × 83 × 128 mm |
| Weight | Approximately 1 kg |
| Battery | Lithium battery, 3.7 V, 5000 mAh; up to 5000 continuous tests within 8 hours on a full charge |
| Display | TFT true-color 3.5-inch capacitive touchscreen |
| Interfaces | USB, Bluetooth |
| Data Storage | 1,000 reference samples, 10,000 test samples |
| Languages | Simplified Chinese, English, Traditional Chinese, Russian |
| Operating Environment | 10–50°C; humidity no higher than 85% RH, non-condensing |
| Storage Environment | -20–50°C; humidity no higher than 85% RH, non-condensing |
| Calibration | Built-in white-tile parameters, external white tile, black trap |
| Calibration Intervals | 4 hours, 8 hours, 24 hours, or at power-on |
| Standard Accessories | Power adapter, data cable, manual, quality-management software (available from the official website), calibration box, black trap, protective cover, wrist strap |
| Optional Accessories | Miniature printer |
| Industries | Automotive, plastics, coatings, cosmetics, special-effect surface finishing |
| Main Applications | Metallic paint, pearlescent paint, special-effect colors, multi-angle color-difference management, and quality control |
Specification note: The KS012 is intended for applications requiring 12-angle color measurement and effect-parameter analysis for metallic, pearlescent, and special-effect colors. For samples with pronounced goniochromatic effects or sparkle, color-travel, or graininess evaluation needs, provide sample conditions, required measurement angles, surface gloss, reference-standard setup, and data-management workflow to confirm suitability for your quality-control requirements. Confirm final supply contents, custom aperture configuration, software functions, and accessories with Fulcrum Technology.