KS012 Multi-Angle Spectrophotometer (12 Angles)

The KS012 multi-angle spectrophotometer is designed for color evaluation of metallic, pearlescent, special-effect, automotive topcoat, plastic appearance, cosmetic packaging, and industrial coating samples that require multi-angle assessment. Compared with conventional single-angle instruments, multi-angle measurement records changes in lightness, chroma, and hue across viewing angles, helping R&D color matching, incoming inspection, process monitoring, batch comparison, and shipment acceptance teams establish a more complete color-management workflow. Confirm suitability based on coating type, effect pigments, flat or curved sample geometry, surface gloss, required measurement angles, data management, and quality-control procedures.

Product Overview

KS012 Multi-Angle Spectrophotometer | 12-Angle Color Evaluation for Special-Effect Materials

The KS012 multi-angle spectrophotometer is designed to evaluate color appearance that changes with viewing angle across coatings and materials. It is suited to metallic, pearlescent, solid, and special-effect colors, automotive topcoats, plastic appearance parts, cosmetic packaging, and industrial coatings.

Multi-angle measurement records color at twelve viewing angles, helping teams assess changes in lightness, chroma, and hue as the viewing direction changes. This can support R&D color matching, incoming inspection, process monitoring, batch comparison, and shipment acceptance. Confirm suitability according to coating type, effect pigments, sample geometry, surface gloss, required angles, data management, and quality-control procedures.

Key Features

KS012 Multi-Angle Spectrophotometer Applications

Designed for color evaluation of materials whose appearance varies with viewing angle, including coatings and special-effect colors.

01

12-Angle Color Assessment

Collect multi-angle color data to document appearance changes across viewing directions and support evaluation of gonioapparent materials.

02

For Metallic and Pearlescent Coatings

Evaluate metallic flakes, pearlescent pigments, solid colors, and other special-effect finishes across face, side, and highlight views.

03

Document Appearance Changes by Angle

Review changes in lightness, chroma, and hue as viewing direction changes to build a more complete color record.

04

Assess Flat and Curved Parts

Consider the instrument for automotive topcoats, plastic appearance parts, cosmetic packaging, and industrial coatings; confirm sample geometry and surface condition for the intended measurement.

05

Support Color Matching and Quality Control

Use multi-angle records to support R&D color matching, incoming inspection, process monitoring, batch comparison, and shipment acceptance workflows.

06

Confirm Measurement Conditions Before Adoption

Review coating type, effect pigments, flat or curved sample geometry, surface gloss, required measurement angles, data management, reference standards, and internal acceptance criteria before selecting the instrument.

Selection Guidance

For applications that need broader multi-angle color analysis, consider the KS012 alongside the KS006 and KS003. Select a model based on the number of measurement angles required, sample conditions, inspection objectives, and quality-control workflow. Confirm detailed specifications and suitability with Fulcrum Technology before adoption.

Contact Fulcrum Technology to discuss KS012 selection

429 container


Specifications

KS012 Multi-Angle Spectrophotometer Specifications

The specifications below are provided as a reference for product selection, procurement, and quality-control implementation. The KS012 uses 12 measurement angles for metallic, pearlescent, special-effect, automotive exterior, plastic-part, cosmetic-packaging, and special-effect surface applications. Confirm suitability based on flat or curved sample geometry, surface gloss, effect pigments, required effect parameters, data management, and quality-control workflow.

Product ModelKS012
Product NameMulti-Angle Spectrophotometer
SeriesKS012 Series Multi-Angle Spectrophotometer
Measurement Geometry12 measurement angles (7 measurement light sources + 1 camera illumination source, 2 receivers)
Color Measurement Angles45° receiver: 45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, 45as110°; 15° receiver: 15as-45°, 15as-15°, 15as15°, 15as-30°, 15as45°, 15as80°
StandardsASTM D2244, ASTM E308, ASTM E1164, ASTM E2194, ASTM E2539, DIN 5033, DIN 5036, DIN 6174, DIN 6175-1, DIN 6175-2, ISO 7724, ISO 11664-4, SAE J1545
Product FeaturesMulti-angle color measurement and quality-control comparison for solid, metallic, pearlescent, and other complex special-effect colors. Actual evaluation depends on sample conditions, reference-standard setup, and internal acceptance criteria.
Illumination SourceBlue-enhanced full-spectrum LED
Light Source Lifetime10 years or 5 million measurements
Spectral DispersionConcave grating
Sensor256-pixel dual-array CMOS image sensor
Measurement Wavelength Range400–700 nm
Wavelength Output Interval10 nm
Half-Bandwidth10 nm
Measurement Range0–600%
Measurement ApertureIllumination Φ23 mm / sample area 9 × 12 mm; optional customization: illumination Φ10 mm / sample area 6 × 8 mm
Color SpacesCIE LAB, XYZ, Yxy, LCh, βxy, DIN Lab99, RGB, Hunter Lab
Color-Difference FormulasΔE*ab, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00, DIN ΔE99, ΔE DIN6175, multiple automotive-brand formulas, ΔE (Hunter), ΔE*ch, ΔE*uv
Other Color MetricsFlop Index, goniochromatic index, metamerism
Observer Angles2° / 10°
IlluminantsD65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83 / U30), B, U35, NBF, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, LED-C2, LED-C3, LED-C5
Display ContentSpectral graphs / data, sample color values, color-difference values / graphs, pass / fail results, color simulation, sample effect values, effect differences
Measurement TimeApproximately 1 second per angle; approximately 12 seconds for all angles
Spectral Reflectance RepeatabilityStandard deviation within 0.08%
Colorimetric Repeatability0.02 ΔE*ab (average of 30 white-tile measurements at 5-second intervals after instrument warm-up and calibration)
Color ReproducibilityΔE < 0.10 (average of gray BCRA tiles); ΔE < 0.25 (average of color BCRA tiles)
Inter-Instrument Difference0.18 ΔE*00 (average across 12 BCRA Series II color tiles)
Effect ParametersSparkle, graininess, and color travel
Effect MeasurementSix-angle sparkle and color-travel measurement: 15as-45°, 15as-30°, 15as-15°, 15as15°, 15as45°, 15as80°; 15d diffuse graininess
Effect RepeatabilityShort-term sparkle repeatability: 0.11% (standard deviation over 10 measurements); short-term graininess repeatability: 0.08% (standard deviation over 10 measurements)
Effect ReproducibilitySparkle reproducibility: 1.8% (standard deviation over 10 measurements); graininess reproducibility: 1.3% (standard deviation over 10 measurements)
TriggeringButton trigger, software trigger
Measurement ModesSingle measurement, average measurement (1–99 times), continuous measurement (1–99 times)
PositioningColor camera preview
Dimensions195 × 83 × 128 mm
WeightApproximately 1 kg
BatteryLithium battery, 3.7 V, 5000 mAh; up to 5000 continuous tests within 8 hours on a full charge
DisplayTFT true-color 3.5-inch capacitive touchscreen
InterfacesUSB, Bluetooth
Data Storage1,000 reference samples, 10,000 test samples
LanguagesSimplified Chinese, English, Traditional Chinese, Russian
Operating Environment10–50°C; humidity no higher than 85% RH, non-condensing
Storage Environment-20–50°C; humidity no higher than 85% RH, non-condensing
CalibrationBuilt-in white-tile parameters, external white tile, black trap
Calibration Intervals4 hours, 8 hours, 24 hours, or at power-on
Standard AccessoriesPower adapter, data cable, manual, quality-management software (available from the official website), calibration box, black trap, protective cover, wrist strap
Optional AccessoriesMiniature printer
IndustriesAutomotive, plastics, coatings, cosmetics, special-effect surface finishing
Main ApplicationsMetallic paint, pearlescent paint, special-effect colors, multi-angle color-difference management, and quality control

Specification note: The KS012 is intended for applications requiring 12-angle color measurement and effect-parameter analysis for metallic, pearlescent, and special-effect colors. For samples with pronounced goniochromatic effects or sparkle, color-travel, or graininess evaluation needs, provide sample conditions, required measurement angles, surface gloss, reference-standard setup, and data-management workflow to confirm suitability for your quality-control requirements. Confirm final supply contents, custom aperture configuration, software functions, and accessories with Fulcrum Technology.

top